Eltherm ELSR-LS Heater Cable – Self Regulating Trace Heating Cable (Up to 80 Degrees Celsius)

Eltherm ELSR-LS Heater Cable

T&D – Eltherm Heating Cables Distributor

Eltherm ELSR-LS Heater Cables – Trace Heating

Eltherm ELSR-LS self-regulating trace heating cables provide process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 80° Celsius – with IECEx and ATEX Certification Eltherm ELSR-LS trace heating cables are suitable for Zone 1 and Zone 2 hazardous areas.

Eltherm ELSR-LS HEATer CABLE – SPECIFICATION

Eltherm ELSR-LS Heater Cable wattages per metre at 10°C – 10, 15, 25 and 30 watts.

  • Nominal Supply Voltage : 230v
  • Maximum Exposure Temperature : Power off 80°C, power on 65°C
  • Minimum Installation Temperature : -50° Celsius
  • Minimum Heater Cable Bend Radius : 25mm
  • Heater Cable Outer Jacket: TPE-O
  • Bus Wire: 1.23mm² Nickel plated copper

Hazardous Area Heating ATEXHazardous Area Classification: IBExU II 2G Ex e IIC T6 Gb, II 2D Ex tb IIIC TX Db

Hazardous Area Heating ATEXCable Classification: EPS II 2G Ex e IIC Gb, II 2D Ex tb IIIC Db

Hazardous Area Certificates: 12ATEX1431U, IECEx EPS 12.0006UHazardous Area Heating ATEX

Eltherm ELSR-LS self-regulating heater cables are available in two cable designs:

  • BO: Protective braid and a thermoplastic outer jacket
  • AO: Aluminium foil and a thermoplastic outer jacket
Eltherm ELSR-LS Heater Cable IECEx & ATEX Certified for Hazardous Area Heating & Process Temperature Maintenance

Eltherm ELSR-LS Heater Cable IECEx & ATEX Certified for Hazardous Area Heating & Process Temperature Maintenance

Trace Heating Cable Selection Table – Eltherm ELSR-LS

Contact T&D for technical guidance, heat loss calculations for pipework systems and optimum specification of the correct trace heater cable for your application.

Eltherm ELSR-LS Heater CableNominal OutputCable Dimensions (mm)Cable Weight Approx (g/m)
ELSR-LS-10-2-AO10 w/m at 10ºC10.3 x 5.578
ELSR-LS-10-2-BO10 w/m at 10ºC10.8 x 5.698
ELSR-LS-15-2-AO15 w/m at 10ºC10.3 x 5.578
ELSR-LS-15-2-BO15 w/m at 10ºC10.8 x 5.698
ELSR-LS-25-2-AO25 w/m at 10ºC10.3 x 5.578
ELSR-LS-25-2-BO25 w/m at 10ºC10.8 x 5.698
ELSR-LS-30-2-AO30 w/m at 10ºC10.3 x 5.578
ELSR-LS-30-2-BO30 w/m at 10ºC10.8 x 5.698

 

Trace Heating

 

Eltherm ELSR-LS Heater Cable - Self Regulating Trace Heating Cable - Power Output

Eltherm ELSR-LS heater cable power output on insulated metallic pipes in accordance with EN 62395-1

Eltherm ELSR-LS – Applications

  • Pipe heat tracing
  • Frost protection for industrial applications
  • Temperature maintenance for pipes and vessels
  • Chemical & petrochemical industries
  • Paints & varnishes
  • Automotive
  • Food processing industry

Eltherm ELSR-N HEATer CABLES

Eltherm video providing a step-by-step termination of ELSR-N heater cable using a EL-ECN termination kit.

Eltherm Heat Tracing With ELSR-LS Heater Cables

Eltherm Heat Tracing With ELSR-LS Heater Cables

Eltherm Heat Tracing With ELSR-LS Heater Cables In Hazardous Areas

Eltherm Heat Tracing With ELSR-LS Heater Cables In Hazardous Areas

Eltherm ELSR-LS heating cables provide temperature maintenance and frost protection to pipework and mechanical services in all industries – typical applications include heating process pipework, instrument lines and storage tanks to maintain viscosity or prevent frost damage as an integral work-task of plant Winterisation.

Eltherm ELSR-LS cables utilise cold-applied installation components to complete the trace heating system – no requirement for “hot-working” permit applications in potentially explosive atmospheres, including Zone 1 and Zone 2 hazardous areas.

Eltherm ELSR-LS Heater Cable

T&D provide value-added specification and design services for both onshore and offshore process heating of pipework, tanks and vessels using trace heating cables and systems. Image : Abtech.

OFFSHORE TRACE HEATING

Trace heating cables provide frost protection for operations and safety purposes in both safe and hazardous areas : loading and unloading pipelines, gas vapour return lines, fire protection lines, strip and cleaning pipelines, fuel oil lines, storage tanks and vessels, deck and tank cleaning lines, engine room fuel and drip lines, cross-over lines, manifolds and safety showers.

Anti-icing or de-icing of escape passages, walkways, staircases and handrails. Water pipe freeze protection is critical for production and process water pipes, fresh/potable and waste water piping and piping used for offshore fire protection systems.

Offshore Trace Heating

Offshore Trace Heating

Eltherm
Eltherm

Eltherm – Heating Cables, Heated Hoses, Surface Heating Mats & Drum Heaters

➡ Did you know? T&D Exports supports the global oil, gas and petrochem industries with an extensive range of Hazardous Area Electrical, Mechanical, Process & Instrumentation Equipment.

➡ Did you know? T&D also Distribute Eltherm Electrical Heated Hoses.