FLEXIM FLUXUS F706 Flowmeter – Ultrasonic Clamp-on Liquid Flowmeter (Permanent)

FLEXIM FLUXUS F706 Flowmeters

FLEXIM FLUXUS F706 Flowmeters – high precision non-invasive ultrasonic liquid flow measurement

FLEXIM manufacture market-leading ultrasonic flow meters – the FLEXIM FLUXUS F706 forms part of the permanent liquid flowmeter range.

Flexim FLUXUS F706 FlowMeter – Advantages

FLEXIM FLUXUS F706 Flowmeter

Flowmeters for Liquids & Gases

  • Highly Economical: No heavy equipment necessary for installation, thus being the ideal solution for remote locations, or poorly accessible areas. Costs reduced due to to clamp-on technology
  • 100% plant availability: The non-invasive measurement technology does not require any process shutdowns – installation and maintenance couldn’t be simpler
  • Extremely low maintenance – Virtually zero maintenance due to use of solid couplant pads instead of high maintenance gels
  • Safety: The F706 clamp-on meter does not add any leakage risk. It also does not require any flanges or gaskest

Flexim FLUXUS F706 FlowMeter – Specifications

Hazardous Area Flowmeter: ATEX / IECEx Zone 2; FM Class I, Div. 2

Hazardous Area Flowmeter: ATEX / IECEx Zone 2; FM Class I, Div. 2

  • Flow channels – 4
  • Quantities of measurement – Standard Volume Flow (Liquids): In accordance with TP-25, ASTM 1250, DA311
  • Quantities of measurement – Further: Volume and mass flow, flow velocity, product detection
  • Medium – Liquid Hydrocarbons and Chemicals
  • Flow velocity range – 0.01m/s … 25 m/s
  • Measurement accuracy (standard) – HART, ModBus and RS485
  • Measurement accuracy (field calibrated)- better than ±0.5% of reading, ±0.01 m/s
  • Repeatability – ±0.15% of reading, ±0.01 m/s
  • Media temperature – -40°C … +200°C (-190°C … +600°C with WaveInjector mounting fixture)
  • Operating temperature of the transmitter – -40°C … +60°C
  • Pipe diameter range – 6mm to 6500mm (independent of pipe wall thickness)
  • Degree of protection – Transmitter: IP66, Transducers: up to IP68
  • Available Hazardous Area Classification – ATEX / IECEx Zone 2; FM Class I, Div. 2
  • Communication Protocol – HART, Modbus RTU, Modbus TCP, RS485
  • Inputs – Up to 4 Inputs (temperatue Pt100/Pt1000), current, voltage, binary
  • Outputs – Up to 4 Outputs: (active/passive) current, voltage, frequency, binary

ATEX IECEx Zone 2; FM Class I, Div. 2

hazardous area Flow Meter

FLEXIM FLUXUS F706 - Ultrasonic Clamp-on Liquid Flowmeter

FLUXUS F706 Flowmeter. T&D Distribute FLEXIM Flowmeters, contact us.

Flow Meter Applications

FLEXIM FLUXUS F706 flowmeter uses include :

  • Flow Measurement in Leak Detection Systems – leak detection applications depend on flowmeters with highest flow measurement accuracy, wide turndown and especially good repeatability and reliability
  • Check Metering- provides metering redundancy, providing an increase in reliability and accountability.
  • Pipeline Monitoring and Liquid Detection – pipelines have to be monitored closely – especially within tank terminals where various hydrocarbon products can successively pass within the same line

 

Also available: FLEXIM FLUXUS G706 Gas Flowmeter

FLEXIM FLOW METERS

Flexim Flowmeters - Portable Permanent Gas Liquid Flowmeters & Ultrasonic Meters

Flexim Flowmeters – Portable & Permanent (Liquids & Gases) & Ultrasonic Clamp-on

Flowmeters - Ultrasonic Non Invasive Flow Measurement Meters - FLEXIM

Flowmeters for Hazardous Area Liquid & Gas Flow Measurement. ATEX, IECEx Zone 2, EAC TR-TS, Inmetro Approved Ultrasonic Meters from FLEXIM.

➡ Did you know? FLEXIM FLUXUS ultrasonic clamp-on flowmeters are available for hazardous areas with IECEX / ATEX Certification – ask T&D about explosion proof offshore flowmeters.

Data Sheets