FLEXIM FLUXUS F721 Flowmeter – Ultrasonic Clamp-on Liquid Flowmeter (ATEX & IECEx Zone 2 Hazardous Area)

FLEXIM FLUXUS F721 Flowmeters (Permanent)

FLEXIM FLUXUS F721 Flowmeters – a state-of-the-art measuring solution even for the most challenging applications with ATEX & IECEx approval for Zone 2 hazardous areas

FLEXIM manufacture market-leading ultrasonic flow meters – the FLEXIM FLUXUS F721 forms part of the permanent liquid flowmeter range.

Flexim FLUXUS F721 FlowMeter – Advantages

FLEXIM FLUXUS F721 Flowmeter

Flowmeters for Liquids & Gases

  • No downtime or maintenance thanks to non-intrusive design
  • Suitable for use in hazardous areas with following approvals (ATEX, IECEx Zone 2, FM Class I, Div. 2, EAC TR-TS, Inmetro)
  • Output of measurement data every 10ms
  • Accurate measurements of slurries and liquids
  • High operational safety with no risk of leaks
  • High measuring accuracy, even at low flow velocities due to matched transducers using FLEXIM FLUXUS F721
  • Cost effective solution with a calibration certificate
  • Accurate bi-directional, highly dynamic flow measurement of liquids
  • Complete monitoring of processes as well as supervision an control of critical operations

Flexim FLUXUS F721 FlowMeter – Specifications

Hazardous Area ATEX, IECEx Zone 2 Flowmeter

Hazardous Area ATEX, IECEx Zone 2 Flowmeter

  • Flow channels – 1 or 2
  • Operating temperature of the flow meter transmitter – -40°C … 60°C
  • Degree of ingress protection – Transmitter: IP66, Transducers: up to IP68
  • Hazardous Area Classification (optional) –  ATEX and IECEx Zone 2, FM Class I, Div. 2, Inmetro, EAC TR-TS
  • Flowmeter outputs – Maximum 4, Available are: Temperature (PT 100 4-wire), current, voltage
  • Communication protocol – Modbus, HART, Foundation Fieldbus, Profibus PA, BACNet
  • Media temperature (liquid) – -40°C … 200°C (-190°C … +600°C with WaveInjector mounting fixture)
  • Pipe diameter range – 6 mm … 12000 mm (no limitations on wall thickness and material)
  • Flow velocity range – 0.01 … 25 m/s
  • Measurement accuracy – ±0.5 % of reading, ±0,01 m/s (without applicative disturbances)
  • Measurement accuracy (extended calibration) – ±1.2 % of reading, ±0,01 m/s
  • Measurement accuracy (field calibrated) – ±0.5 % of reading, ±0,01 m/s
  • Repeatability – ±0.15% of reading, ±0,01 m/s
  • Menu languages – English (US), German, French, Dutch, Spanish, Russian, Chinese and others

ATEX & IECEx Zone 2 Hazardous Area Flow Meter

What is Hazardous Area Zone 2?

  • Zone 2 Hazardous Area – a potentially explosive atmosphere in which an explosive liquid or gas atmosphere is not likely to occur in normal operation and if it occurs will exist only for a short time. “Short time” is not officially quantified according to IECEx or ATEX but commonly accepted by hazardous area industries as being prevalent for less than 10h/yr.
FLEXIM FLUXUS F721 - Ultrasonic Clamp-on Liquid Flowmeter (Permanent)

FLUXUS F721 Flowmeter. T&D Distribute FLEXIM Flowmeters, contact us

FLEXIM FLUXUS F721 Flowmeter (Permanent) - Transducer

FLEXIM FLUXUS F721 Flowmeter (Permanent) – Transducer

Flow Meter Applications

FLEXIM FLUXUS F721 flowmeter are used in the following industries :

  • Oil & Gas
  • Chemical
  • Petrochemical
  • Water & Wastewater
  • Power Generation
  • District Energy
  • Pharmaceuticals
  • Semiconductor
  • Food & Beverage
  • Mining
  • Energy Efficiency

 

FLEXIM FLOW METERS

Flexim Flowmeters - Portable Permanent Gas Liquid Flowmeters & Ultrasonic Meters

Flexim Flowmeters – Portable & Permanent (Liquids & Gases) & Ultrasonic Clamp-on

Flowmeters - Ultrasonic Non Invasive Flow Measurement Meters - FLEXIM

Flowmeters for Hazardous Area Liquid & Gas Flow Measurement. ATEX, IECEx Zone 2, EAC TR-TS, Inmetro Approved Ultrasonic Meters from FLEXIM.

➡ Did you know? FLEXIM FLUXUS ultrasonic clamp-on flowmeters are available for hazardous areas with IECEX / ATEX Certification – ask T&D about explosion proof offshore flowmeters.

Data Sheets