FLEXIM FLUXUS PIOXS – Ultrasonic Clamp-on Liquid Flowmeter (Zone 2 Hazardous Area)

FLEXIM FLUXUS PIOX Flowmeters

FLEXIM FLUXUS PIOXS Flowmeters – mainly used for concentration analysis during process control

FLEXIM manufacture market-leading ultrasonic flow meters – the FLEXIM FLUXUS PIOXS forms part of the permanent liquid flowmeter range.

Flexim FLUXUS PIOXS FlowMeter – Advantages

FLEXIM FLUXUS PIOXS Flowmeter

Flowmeters for Liquids & Gases

  • No downtime or maintenance thanks to non-intrusive design
  • Clamp-on design keeps installation time to a minimum and because the FLEXIM FLUXUS PIOXS has no contact with the media no special materials are required
  • Hygenic and highly dynamic flow measurement method, suitable for ultrapure media
  • No pressure loss, no risk of leakage, no contamination
  • No chemical compatibility issues, , watertight, no pressurized parts

Flexim FLUXUS PIOXS FlowMeter – Specifications

Measuring quantities (temperature compensated) w%, ° Brix (Plato, Oechsle) additional quantities programmable
Flow velocity range 0.01 … 25 m/s
Pipe diameter range 6mm … 6500mm (no limitation on wall thickness and materials)
Measurement accuracy – concentration and density up to 0.1% of reading (depending on media, concentration and temperature range)
Measurement accuracy Massflow: ±1.2 % of reading ±0.01 m/s
Measurement accuracy
(field calibrated)
Massflow: ± 0.5% of reading ±0.01 m/s
Operating temp. (media) – 40 °C … + 200 °C
(-190 °C … + 400°C with WaveInjector)
Operating temperature of the transmitter PIOX S704: -20 °C… + 60 °C
PIOX S705: -40 °C… + 60 °C
Degree of protection Transducers: IP65 to IP68, optional ATEX (IECEx) Zone 2 / FM Class I, Div. 2 Transm.: PIOX S704: IP65, ATEX (IECEx) Zone 2 opt
Explosion protection PIOX S705: IP66, stainless steel enclosure, ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional PIOX S709: 19 inch rack version
Communication Protocol HART, ModBus, Foundation Fieldbus
Outputs  A variety of combinations are available from the following: current (0/4 mA … 20 mA), voltage, frequency, pulse, alarm
Inputs Maximum 4, Available are: Temperature (PT 100 4-wire), current, voltage
FLEXIM FLUXUS PIOXS - Ultrasonic Clamp-on Liquid Flowmeter

FLUXUS PIOXS Flowmeter. T&D Distribute FLEXIM Flowmeters, contact us.

ZONE 2 HAZARDOUS AREA FLOW METER

Zone 2 Hazardous Area Flowmeter

Zone 2 Hazardous Area Flowmeter

ATEX CERTIFIED

Explosion Protection: ATEX (IECEx) Zone 2 and FM Class I, Div. 2 optional

What is Hazardous Area Zone 2?

  • Zone 2 Hazardous Area – a potentially explosive atmosphere in which an explosive liquid or gas atmosphere is not likely to occur in normal operation and if it occurs will exist only for a short time. “Short time” is not officially quantified according to IECEx or ATEX but commonly accepted by hazardous area industries as being prevalent for less than 10h/yr.

 

Flow Meter Applications

The FLEXIM FLUXUS PIOXS is the perfect solution for monitoring chemically aggressive and corrosive media in addition to ensuring all processes meet the correct standards regarding cleanliness, purity and protection from contaminates.

FLEXIM FLUXUS PIOXS flowmeter industries :

  • Chemical Industry
  • Fiber Chemistry
  • Fertilizer Industry
  • Electronic Industry
  • Food & Bevearge Industry

FLEXIM FLOW METERS

Flexim Flowmeters - Portable Permanent Gas Liquid Flowmeters & Ultrasonic Meters

Flexim Flowmeters – Portable & Permanent (Liquids & Gases) & Ultrasonic Clamp-on

Flowmeters - Ultrasonic Non Invasive Flow Measurement Meters - FLEXIM

Flowmeters for Hazardous Area Liquid & Gas Flow Measurement. ATEX, IECEx Zone 2, EAC TR-TS, Inmetro Approved Ultrasonic Meters from FLEXIM.

➡ Did you know? FLEXIM FLUXUS ultrasonic clamp-on flowmeters are available for hazardous areas with IECEX / ATEX Certification – ask T&D about explosion proof offshore flowmeters.

Data Sheets