Pressure Reducing Valve – WRAS Approved

Valve Type: Pressure Reducing Valve (PRV)

Valve Manufacturer: RWC Reliance Water Controls

Harron valves are combination valves featuring a pressure reducing valve with cartridge design and integral thermal balancing valve reducing potential leaks and installation time.

HARRON VALVES – PRESSURE REDUCING VALVE

WRAS APPROVED VALVE

  • Single unit cartridge design ensures a quick and easy installation
  • Reduces design complexity and avoids installation error
  • Reduced leakage potential and easy maintenance, saving cost
  • Supplied pre-insulated further reducing installation time and cost
  • Easy temperature adjustment between 40-65°C with tamperproof cap
  • Built-in disinfection function to the valve protecting against Legionella
  • Dry-fit thermometer – no need to drain the system down
  • High flow rate design valve
  • ‘Lift and turn’ mechanism for ease of pressure adjustment
  • One piece Easiset® cartridge with fully serviceable strainer
  • Available with SharkBite® Metal Push-fit connections for even quicker installation
WRAS Valves

RWC Pressure Reducing Valves Are WRAS Approved

Harron Valve Application

Harron valves are used on circulating hot water systems – the pressure reducing valve ensures water pressure is reduced, balancing the hot water system by regulating water flow depending on the temperature. Harrow pressure reducing valves have a built in disinfection function to protect against Legionella and are available with SharkBite connections.

Harron Valve - Pressure Reducing Valves

Harron Valve – Pressure Reducing Valves

PRESSURE REDUCING VALVE SELECTION TABLE

 Valve Pressure (Preset)Valve Models (WRAS Approved)RWC Order Reference 
 1/2 ”  bar Harron Valve RWC TREG200001
 3/4 ”  bar Harron Valve RWC TREG200002
 1/2 ”  bar Harron Valve + SharkBite Connections RWC SBTREG200001
 3/4 ”  bar Harron Valve + SharkBite Connections RWC SBTREG200002

HARRON VALVE SPECIFICATION

  • Temperature Set Range: 40-65° Celsius
  • Factory Pre-set Temperature: 58° Celsius
  • Temperature Range For Thermal Disinfection: >70° Celsius
  • Maximum Working Pressure: 16 bar
  • Maximum Working Temperature: 85° Celsius
  • Adjustable Set Pressure: 1.5 – 5.5 bar
  • Valve Pressure Reduction Ratio: 10:1

Valve Connection Sizes

  • RWC TREG200001 1/2″
  • RWC TREG200002 3/4″

PRESSURE REDUCING VALVE MATERIALS

  • Valve Body: DZR Brass
  • Internal Components: DZR Brass
  • Seals: Viton & NBR Elastomer
  • Spring: Stainless Steel
  • Strainer: Stainless Steel
  • Diaphragm: NBR Elastomer Nylon Mesh
  • Cover: Glass Filled Nylon Polymer
  • Insulation: Polyethylene