Thermon BSX 5-2 Heat Tracing Cables (15 Watts Metre)

Thermon BSX 5-2 - Self-Regulating Heat Trace Cables

Thermon BSX 5-2 – Self-Regulating Heat Trace Cables

Trace Heating Cables

Thermon BSX 5-2 trace heating cables are specified to provide frost protection and process temperature maintenance up to 65° Celsius : suitable for trace heating pipes, drums, process skids, valves, flexible hoses and vessels.

Thermon BSX 5-2 heating cables provide a power output of 5 watts per metre (15 watts per foot) at 50°F (10°C) and are available in both 120 Volt and 240 Volt service voltage options. Order Thermon BSX 5-1 for 120 Volt heat trace cables.

Trace Heating Cables

Pipe Freeze Protection Cables

Thermon BSX 5-2 Heat Tracing Cables – Power Output Curves & Circuit Breaker Sizing

Thermon BSX 5-2 Heat Tracing Cables

Thermon BSX 5-2 Heat Tracing Cables

 

240 Vac Service VoltageMaximum Circuit Length³ vs. Breaker Size ft (m)
Thermon Order CodeStart-Up Temperature ºF (ºC)20A30A40A
BSX 5-250 (10)480 (146)600 (183)600 (183)
0 (-18)395 (120)590 (180)600 (183)
-20 (-29)350 (107)525 (160)590 (180)
-40 (-40)315 (96)475 (145)530 (162)

 

HEAT TRACE APPLICATION – Deluge Skids Process Temperature Maintenance

Deluge skids are process packages used to control the flow of water or water/foam solution in fixed fire suppression, cooling or gas containment systems.

Heat Tracing Cables

Deluge Skids – Thermon heating cables are used to trace heat distribution pipework, drain lines, test lines and valves on onshore and offshore deluge skids. Image : Blazeman

Thermon BSX 5-2 Heat Tracing Cables – Cable JacketS

Standard polyolefin heating cable overjacket (Thermon OJ) provides cable and braid protection for exposure to aqueous inorganic chemicals. Thermon FOJ fluoropolymer trace heater cable overjacket provides enhanced protection against corrosive and aggressive organic chemicals. Both heat trace cable options are ATEX and IECEx Certified for installation in Zone 1 and Zone hazardous areas.

Contact T&D for an extensive range of Hazardous Area Electrical, Mechanical, Process & Instrumentation Equipment.

➡ Did you know?  T&D can specify safe Gas Detection Equipment for any industrial application;  including ATEX & IECEx certified gas detectors for use in Zone 1 and Zone 2 hazardous areas in the oil, gas and petrochem industries.

Hazardous Area Gas Detection

Crowcon Hazardous Area Gas Detectors (ATEX Certified) Zone 1 & Zone 2. Contact T&D for with your enquiry.

Data Sheets