Thermon VSX Heat Tracing Cables (Self-Regulating, Hazardous Area Certified)

Thermon Heat Trace Cables

Thermon VSX Heat Trace Cables – Trace Heating

Heating Cables

Thermon VSX heat tracing cables provide process temperature maintenance and frost protection to pipework, instrument lines, tanks, IBCs and drums up to 149°C (300°F) – with IECEx and ATEX Certification Thermon VSX trace heating cables are suitable for Zone 1 and Zone 2 hazardous areas.

VSX self-regulating heating cables offer high performance heating in applications where high temperature maintenance or exposure is needed. The heat output of VSX series cable varies in accordance with the surrounding temperature by reducing its own thermal output in response to an increase in ambient temperature. Due to its high self-regulating characteristics, Thermon VSX heat tracing cables can be installed in hazardous areas requiring a temperature class rating of T3. VSX cables are approved for use in ordinary (nonclassified) areas, hazardous (classified) areas, and Zone 1 and 2 classified areas.

Further information about Hazardous Area Zones | T Class Ratings

Thermon VSX Heat Tracing Cables

Thermon VSX Heat Tracing Cables

Thermon VSX Heat Tracing Cables – Specification

Thermon VSX heat trace cables are available in the following wattage densities at 10°C (50°F): 16, 33, 49 and 66 watts per metre or 5, 10, 15 and 20 watts per foot.

  • Nominal Supply Voltage : 110-120 Vac or 208-277 Vac
  • Maximum Maintain Temperature : 149°C (300°F)
  • Maximum Exposure Temperature : Intermittent power-on 232°C (450°F), Intermittent power-off 250°C (482°F), Continuous power-off 204°C (400°F)
  • Minimum Installation Temperature : -51°C (-60°F)
  • Minimum Cable Bend Radius : At -15ºC (5°F) 10mm (0.38″) ; at -60ºC (-76°F) 32mm (1.25″)
  • Temperature Class Rating : T3 200°C (392°F)

Thermon VSX self-regulating trace heating cables are designed specifically for applications where high temperatures need to be maintained or high temperature exposure is required e.g steam purging.

thermon vsx ordering information

All cables require a connection kit to comply with approval requirements. Further information on accessories to complete a heater circuit installation can be found in the Thermon Product Index.

Thermon Cable Code
120 Vac Nominal
Thermon Cable Code
240 Vac Nominal
Power Output at 50°F (10°C)
w/ft (m)
VSX 5-1 VSX 5-2 16 Watts (5)
VSX 10-1 VSX 10-2 33 Watts (10)
VSX 15-1 VSX 15-2 49 Watts (15)
VSX 20-1 VSX 20-2 66 Watts (20)

POWER OUTPUT CURVES

The power outputs shown apply to cable installed on insulated metallic pipe (using the procedures outlined in IEEE 515) at the service voltages stated below. For use on other service voltages, contact us.

Thermon VSX

Heat Tracing Cables - Valves Pumps Flanges

Thermon VSX Heat Trace Cables – shown providing trace heating to i) Valve ii) Pump iii) Flange.

Thermon VSX Heat Trace Cable – Hazardous Area Certifications

FM Approvals

  • Ordinary Locations
  • Hazardous (Classified) Locations
  • Class I, Division 2, Groups B, C and D
  • Class II, Division 2, Groups F and G
  • Class III, Divisions 1 and 2
  • Class I, Zones 1 and 2, AEx e II

Underwriters Laboratories Inc.

  • Ordinary Locations
  • Hazardous (Classified) Locations
  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 2, Groups F and G
  • Class III, Divisions 1 and 2

Canadian Standards Association

  • Ordinary Locations
  • Hazardous (Classified) Locations
  • Class I, Divisions 1 & 2, Groups A, B, C and D
  • Class II, Divisions 1 & 2, Groups E, F and G
  • Ex e II

ATEX Directive

IECEx

Trace Heating

Electric Heat Tracing Cables For Hazardous Areas

Thermon VSX Heat Tracing Cables

Thermon video providing an overview of best practices for installing heat trace cables to both industrial and hazardous area location pipework. Video covers heat trace cable selection, testing, inspection and pipework preparation prior to installing cables to pipes, valves, flanges and un-insulated pipe supports.

Thermon Electric Heat Tracing System Using VSX Heating Cables

A complete electric heat tracing system will typically include the following components:

1 Trace Heating Cables – depending on the application and system requirements heat trace cables are available in the following technologies: i) Series Constant Wattage ii) Parallel Constant Wattage iii) Power-Limiting iv) Self-regulating type cables.
2. Power Connection Kit
3. RTD Sensor or Control Thermostat
4. In-line/T-splice Kit (permits two or three heat trace cables to be spliced together)
5. Cable End Termination
6. Fixing Tape (to attach heater cables to pipework)
7. “Electric Heat Tracing” Label (peel-and-stick type self-adhesive warning labels)
8. Thermal Insulation

Should you require Heat Trace System design or installation support please do not hesitate to contact us.

Trace Heating Accessories

The following trace heating ancillary and cable installation components enable the completion of BXS heating cable systems:

THERMON VSX CABLE CONSTRUCTION

Thermon Cable

1.Nickel plated copper bus wires (1.3sqmm)

2. Semiconductive heating matrix and fluoropolymer dielectric insulation

3. Nickel-plated copper braid

4. Fluoropolymer overjacket provides additional protection to cable and braid where exposure to chemicals or corrosives is expected.

Thermon VSX heating cables provide temperature maintenance and frost protection to pipework and mechanical services in all industries – typical applications include heating process pipework, instrument lines and storage tanks to maintain viscosity or prevent frost damage as an integral work-task of plant Winterisation.

Safety & Site Practice for Heat Trace Systems

• Installation of trace heating cables and systems shall be carried out under the supervision of a qualified person.
• Persons involved in the installation and testing of electric trace heating systems shall be suitably trained in all special techniques required, including: i) the purpose and function of the electrical trace heating system, ii) its associated power supply and control equipment and iii) how to recognize and avoid the hazards associated with its operation and maintenance.
• All personnel shall use all appropriate personal protective equipment (PPE), including protective arc flash clothing, to protect against potential arc and electric shock hazards.
• All personnel shall comply with all applicable safety and health guidelines, including Thermon requirements, the regulations outlined in the NEC and CEC, and EN/IEC/IEEE 60079-30-2 for hazardous areas (as applicable), and any other applicable national and local electric codes.
• During installation, the trace heating system parameters shall be verified. Tests shall be performed in the field and documented in the Installation Report as instructed.

For series constant-watt trace heaters (HTEK, TEK, TESH), do not allow the heating portion of the trace heater cable to touch, cross over, or overlap itself.

Heat Tracing Using Trace Heating Cables