Ashcroft Pressure Gauges – 7 Steps To Choosing The Correct Pressure Gauge
When selecting a mechanical Ashcroft Pressure Gauge with no external power input, there are a number of criteria that must be considered prior to choice and installation.
The 7 points below set out the key steps that must be considered, however there are also further points that must also be considered including the environmental issues, workplace location (safe or hazardous area) and mounting requirements. When considering the main points below and selecting the correct gauge product longevity, performance and reliability will be significantly improved.
The 7 main points to consider when selecting a pressure gauge are:
Step 1 – PRESSURE Gauge Accuracy
The accuracy of mechanical pressure gauges is described as a percentage of the full-scale range and while requirements differ between industries, the general guidelines are:
- Test gauges and standards: 0.25% – 0.10% full scale accuracy
- Critical processes: 0.5% full scale accuracy
- General industry processes: 1.0% accuracy. Less critical commercial uses: 2.0% accuracy: Refer to ASME B40.100 for more information on accuracy.
Step 2 – gauge Dial Size
Pressure gauge dials range in size from less than 1″ to 16″ in diameter and readability requirements, space limitations and required gauge accuracy will determine the dial size chosen. Any accuracies of 0.25% to 0.5% will generally have dial size of 4½” or larger as more dial graduations are required.
Step 3 – Case Style/Material
Prior to choosing and installing a pressure gauge, there are many environmental considerations such as ambient temperature, condensation, humidity, water, chemicals and air-borne particulate.
The ambient temperature can affect the accuracy and integrity of the pressure gauges which are available either temperature compensated or non-temperature compensated and the ambient temperature may require the gauge to be isolated from extreme temperatures.
Where ambient conditions are corrosive and contain a large amount of particulate or if the gauge will be exposed to a wet or humid environment, then a gauge should be specified that is weatherproof/hermetically sealed or liquid filled. The correct case material can prevent corrosion and leaks which will in turn prevent leaks and safety incidents occurring.
Step 4 – Media/Wetted Parts
The gauge process and the wetted parts of the pressure gauge are typically the bourdon tube and socket which must be compatible with the process media. If this not the case, then rust or corrosion can occur and will eventually lead to parts of the gauge failing and potentially cause safety issues.
Step 5 – Pressure Gauge Connection Type
The type of connection and size of connection are available in many varieties including NPT, DIN, JIS, BSP & SAE. Process pressure gauges with 4½” dials or larger are most often supplied with a ½” NPT connection to best support the gauge.
Other factors to consider when selecting a pressure gauge connection include process pressures, gauge size and weight, space limitations, leak integrity, and past experience. In addition, when mounting the pressure gauge, there are a number of options that should be considered including:
- Direct stem mount lower connect
- Remote wall/surface mount lower connect
- Panel surface mount back connect
- Panel hole U-clamp flush mount back connect
- Panel hole front flange flush mount back connect
Step 6 – Connection Location
The location of the gauge connection is a key consideration as there a number of elements that must be considered prior to installation. These include the stem mount lower connection, wall/surface mount lower connect, panel mount back connect U-clamp and front flange flush mount back connection.
Step 7 – Pressure Ranges
The American Society of Mechanical Engineers (ASME) recommends that normal operating pressure of the gauge should be confined to 25%-75% of the scale. If pulsation is present in the process, maximum operating gauge pressure should not exceed 50% of the full-scale range.
Conclusion
To properly select and specify a pressure gauge prior to purchase the user must consider the pressure gauge process, range, environment, accuracy, dial size, connection and mounting requirements – if in doubt, call T&D.
word of Warning
To prevent misapplication, pressure gauges must be selected considering media and ambient operating conditions. Improper application can be detrimental to the gauge, causing failure and possible personal injury, property damage or death.
The information contained here is offered as a guide to enable the safe and proper selection of a pressure gauge.
Users should become familiar with ASME B40.100 (Gauges – Pressure Indicating Dial Type – Elastic Element) before specifying pressure gauges. The document contains essential information regarding pressure gauge construction, accuracy, safety, selection and testing.
Should you require any further information, technical details or selection support to choose the correct pressure gauge, please do not hesitate to contact us.
More Reading
- Ashcroft Pressure Gauges – The World’s Most Trusted Instruments
- How Much Does It Cost If Your Production Capabilities Are Down For An Hour?
Invitation – network, engage, promote
Thorne & Derrick are inviting you to join LinkedIn’s fastest growing Discussion Group – Process & Hazardous Area Industries : Heat Tracing, Gas Detection, Fluid Control & Flow Measurement. News, projects, videos, promotions, whitepapers, jobs, webinars, press plus much more.
ABOUT US
Thorne & Derrick International are your single-source supplier of Electrical, Mechanical, Process & Instrumentation Equipment. T&D provide an outstanding service to UK and international customers – we are highly customer responsive and absolutely committed to providing a world-class service.
T&D supply utilities, power, renewable energy, construction, rail, manufacturing, food/beverage, mining, oil, gas and petrochemical industries – distributing 100,000+ products from 100+ manufacturers from multi-million pound stocks. Since 1985 we have established a solid reputation based on service, integrity and trust.
Further Reading
-
Pressure Gauges & Gauge Attachments ASME B40.100-2013 – Extract Size: 72.83 KB
-
Ashcroft Pressure Gauges – Installation, Operation & Maintenance Guide Size: 1.00 MB