Motor Starters

Motor Starters ATEX IECEx Hazardous Area Zone 1 Zone 2

Electrical Explosion Protection Equipment | Motor Starters | ATEX Certified | Direct on Line (DOL & Star Delta)

Motor Starters | ATEX & IECEX

EXPLOSION PROOF & HAZARDOUS AREA ZONE 1 (21) & ZONE 2 (22)

Thorne & Derrick International, based in the UK, are the leading stockists and suppliers of Explosion Proof Electrical Equipment for hazardous area and explosive atmosphere applications from market-leading brands including Pepperl + Fuchs – this includes a comprehensive range of Explosion Proof Motor Starters for the control of automation, machinery and electrical networks with ATEX & IECEx certification and explosion protection to both Ex d (Flameproof) and Ex e (Increased Safety) applications.

Motor starters suitable for hazardous area Ex d and Ex e motors installed in Zone 1 & Zone 2 (Gas) and Zone 21 & Zone 22 (Dust) are available with various enclosure materials including cast iron, aluminium or stainless steel – Direct On Line starters up to 75kW and Star Delta starters up to 30kW.

Explosion ProofMotor Starters

The DOL range of motor starters and DOLSD range of motor starters with switch disconnectors are safely protected in flameproof enclosures suitable for Ex e motors and are available with various contactor ratings and coil voltages.

The DOL and DOLSD ranges of explosion proof motor starters are designed for safe operation of machinery and drives in gas (Zone 1 & Zone 2) or dust (Zone 21 & Zone 22) explosive atmospheres.

Flameproof motor starters provide hazardous area power switching with explosion protection. Pepperl+Fuchs motor starters enable the safe operation of hazardous area motors up to 75kW.

Direct On Line motor starters feature 3 phase 50/60 Hz contactors with push button operators and are fitted with standard overload relays according to contactor ratings as well as thermal overload protection.

Pepperl+Fuchs motor starters are equipped with an additional rotary switch to enable safe disconnection of the electrical circuit in hazardous area locations – flameproof Star Delta Starters are available from 11kW to 15kW.

Flameproof motor starters are hazardous area certified for both gas and dust explosive areas according to ATEX, IECEx, and GOST-R.

Standard coil voltages are 240V and 415V while other coil voltage and overload ranges are available on request. Ambient temperatures range from -40 °C to +50 °C, with an ingress protection of IP66.


Direct On Line DOL Starters

Explosion Proof Direct On Line Motor Starters for Hazardous Area Motors

Description: The DOL range of motor starters and DOLSD range of motor starters with switch disconnectors are safely protected in flameproof enclosures and are suitable for Ex e motors. Available with various contactor ratings and coil voltages. Metric threaded. Zinc rich epoxy powder primer plus epoxy powder top coat black.

Application: The DOL and DOLSD ranges of motor starters are designed for safe operation of machinery and drives in gas or dust explosion
hazardous areas.

ATEX Certified Motor Starters II 2GD

ATEX Certified DOL Motor Starters II 2GD

Hazardous Area Marking & Certification: Marking to 94/9/EC: II 2GD | Zones: 1 – 21 – 2 – 22 (Gas & Dust).

For type of explosion protection, certificates, ambient temperature ranges and ingress protection please contact us.

Explosion Protection Type

1.1 Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
1.2 Ex d IIB T5 Gb, Ex tb IIIC T87°C Db
1.3 Ex d IIB T5 Gb, Ex tb IIIC T95°C ( ta … +55°C )
1.4 Ex d IIB T6 Gb, Ex tb IIIC T85°C Db

Motor Starter Features:

  • Labeling: OFF – ON (DOLSD range only)
  • Operator Lock: Padlockable in OFF position (DOLSD range only)
  • Enclosure Cover: hinged non-detachable
  • Mounting: 2 x fabricated stainless steel mounting straps
  • A – Maximum external dimension
  • B – Maximum external dimension
  • C – Maximum external dimension
  • D – Fixing holes wheel base
  • E – Fixing holes wheel base
  • F – Cable entry diameter
  • J – Fixing holes diameter
    [A] – Entry face
    [B] – Entry face

Motor Starters

ATEX Motor Starters

ATEX Motor Starters | DOL DOLSD – Direct Online Starters | Enclosures Types for drawing references, dimensions (mm) and approx. weight (kg) contact Thorne & Derrick

Star Delta Starters

Explosion Proof Star Delta Motor Starters for Hazardous Area Motors

Description: The SDS range of star delta motor starters are safely protected in flameproof enclosures. They are suitable for Ex e motors and
available with various contactor ratings and coil voltages. Body: Cast iron, aluminium and stainless steel enclosures with screws (stainless steel). Metric threaded. Zinc rich epoxy powder primer plus epoxy powder top coat black. Contact us for complete electrical and mechanical specifications to ensure the correct selection of motor starter.

Application: The SDS range of motor starters is designed for safe operation of machinery and drives in gas (Zone 1 & Zone 2) or dust (Zone 21 & Zone 22) explosion hazardous areas.

Hazardous Area Marking & Certification: to 94/9/EC: II 2GD | Zones: 1 – 21 – 2 – 22 (Gas & Dust). For type of explosion protection, certificates and ambient temperature range please contact us.

For motor starter drawing references, dimensions (mm) and approx. weight (kg) contact Thorne & Derrick.

Cable Entries (Dimension F)
Face [A]: 1 x M25
Face [B]: 1 x M20, 2 x M25
Cover fixing screws – M8 stainless steel
Ingress protection  – EN60529: IP66
Seal – one piece closed cell neoprene

Explosion Protection Type

Ex d IIB T6 Gb, Ex tb IIIC T76 °C Db (ta … +50 °C)
Ex d IIB T5 Gb, Ex tb IIIC T82 °C Db (ta … +55 °C)

  • A – Maximum external dimension
  • B – Maximum external dimension
  • C – Maximum external dimension
  • D – Fixing holes wheel base
  • E – Fixing holes wheel base
  • F – Cable entry diameter
  • J – Fixing holes diameter
    [A] – Entry face
    [B] – Entry faceMotor Starters ATEX Star Delta Explosion Proof
Explosion Proof Electrical Equipment

Motor Starters


Ex d & Ex e Explosion Protection For Hazardous Areas

Thomas Kasten, Product Marketing Manager for Systems+Solutions at Pepperl+Fuchs, explains the features of the explosion protection type Ex e – Increased Safety. With Ex e, impermissible high temperatures as well as the occurance of sparks and arcs inside and outside of an electrical equipment are avoided by specific design features: potential ignition sources are located inside an enclosure, which has to meet some requirements.

Hazardous Areas

GOST-R & CU TR Certification

EAC EX Certificate for Hazardous Areas

On February 15, 2013 the national Russian certification system GOST R and national Russian technical regulation “On Safety of Machinery Equipment” were withdrawn. Simultaneously, the new Customs Union Technical Regulation (CU TR) for most electrical products was enforced in Russia, Belarus and Kazakhstan.

➡ Please refer to the selection table below for further information about Flameproof Ex d Motor Starters – Ex d explosion-proof suitable for motors located in Zone 1 & Zone 2 (Gas) and Zone 21 & Zone 22 (dust) areas.

Quick Select Product Guide for Electrical Explosion Protection Equipment

The Quick Select Product Guide for Electrical Explosion Protection Equipment is designed for experienced hazardous area users, technicians, and engineers. It presents a comprehensive overview of Pepperl+Fuchs’ Explosion Proof product and solutions offerings based on Ex d, Ex e, and Ex p protection. It will help with selecting the appropriate devices and systems for application planning.

Pepper Fuchs Explosion Protection

Motor Starters | Junction Boxes | Control Stations | Isolators | Distribution Panels | Plugs & Sockets | Explosion Proof


Motor Starters

Selection Table

Pepperl+Fuchs
Order Code
Starter Function Coil Voltage Phases Motor Starter Specification Power Current Cable Terminal Capacity Hazardous Area Marking ATEX
DOL5.5/415 Direct Online Starter 415V 3 Cast Iron – H 218 W 150 D 151mm 5.5kW 12A (AC3) 2x 1-6sqmm for solid cable
2x 1-4sqmm for flexible cable with ferrule
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T87°C Db
DOL1.1/240 Direct Online Starter 240V 3 Cast Iron – H 218 W 150 D 151mm 1.1kW 7A (AC3) 2x 1-6sqmm for solid cable
2x 1-4sqmm for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL1.5/240 Direct Online Starter 240V 3 Cast Iron – H 218 W 150 D 151mm 1.5kW 7A (AC3) 2x 1-6sqmm for solid cable
2x 1-4sqmm for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL11/240/AL Direct Online Starter 240V 3 Cast Aluminium – H 210 W 185 D 156mm 11kW 25A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T95°C ( ta … +55°C )
DOL11/240/Cl Direct Online Starter 240V 3 Cast Iron – H 210 W 185 D 156mm 11kW 25A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T95°C ( ta … +55°C )
DOL11/240/SS Direct Online Starter 240V 3 Cast Stainless Steel – H 210 W 185 D 156mm 11kW 25A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T95°C ( ta … +55°C )
DOL11/415/AL Direct Online Starter 415V 3 Cast Aluminium – H 210 W 185 D 156mm 11kW 25A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T95°C ( ta … +55°C )
DOL11/415/Cl Direct Online Starter 415V 3 Cast Iron – H 210 W 185 D 156mm 11kW 25A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T95°C ( ta … +55°C )
DOL11/415/SS Direct Online Starter 415V 3 Cast Stainless Steel – H 210 W 185 D 156mm 11kW 25A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T95°C ( ta … +55°C )
DOL15/240/AL Direct Online Starter 240V 3 Cast Aluminium – H 210 W 185 D 156mm 15kW 32A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL15/240/Cl Direct Online Starter 240V 3 Cast Iron – H 210 W 185 D 156mm 15kW 32A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL15/240/SS Direct Online Starter 240V 3 Cast Stainless Steel – H 210 W 185 D 156mm 15kW 32A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL15/415/AL Direct Online Starter 415V 3 Cast Aluminium – H 210 W 185 D 156mm 15kW 32A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL15/415/Cl Direct Online Starter 415V 3 Cast Iron – H 210 W 185 D 156mm 15kW 32A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL15/415/SS Direct Online Starter 415V 3 Cast Stainless Steel – H 210 W 185 D 156mm 15kW 32A (AC3) 7 x 1.5-16mm² (1 x ground terminal) II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL18.5/240/AL Direct Online Starter 240V 3 Cast Aluminium – H 335 W 310 D 205mm 18.5kW 40A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL18.5/240/Cl Direct Online Starter 240V 3 Cast Iron – H 335 W 310 D 205mm 18.5kW 40A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL18.5/240/SS Direct Online Starter 240V 3 Cast Stainless Steel – H 335 W 310 D 205mm 18.5kW 40A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL18.5/415/AL Direct Online Starter 415V 3 Cast Aluminium – H 335 W 310 D 205mm 18.5kW 40A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL18.5/415/Cl Direct Online Starter 415V 3 Cast Iron – H 335 W 310 D 205mm 18.5kW 40A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL18.5/415/SS Direct Online Starter 415V 3 Cast Stainless Steel – H 335 W 310 D 205mm 18.5kW 40A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL2.2/240 Direct Online Starter 240V 3 Cast Iron – H 218 W 150 D 151mm 2.2kW 7A (AC3) 2x 1-6mm² for solid cable
2x 1-4mm² for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL22/240/AL Direct Online Starter 240V 3 Cast Aluminium – H 335 W 310 D 205mm 22kW 50A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL22/240/Cl Direct Online Starter 240V 3 Cast Iron – H 335 W 310 D 205mm 22kW 50A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL22/240/SS Direct Online Starter 240V 3 Cast Stainless Steel – H 335 W 310 D 205mm 22kW 50A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL22/415/AL Direct Online Starter 415V 3 Cast Aluminium – H 335 W 310 D 205mm 22kW 50A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL22/415/Cl Direct Online Starter 415V 3 Cast Iron – H 335 W 310 D 205mm 22kW 50A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL22/415/SS Direct Online Starter 415V 3 Cast Stainless Steel – H 335 W 310 D 205mm 22kW 50A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL3/240 Direct Online Starter 240V 3 Cast Iron – H 218 W 150 D 151mm 3kW 7A (AC3) 2x 1-6mm² for solid cable
2x 1-4mm² for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL30/240/AL Direct Online Starter 240V 3 Cast Aluminium – H 335 W 310 D 205mm 30kW 65A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL30/240/Cl Direct Online Starter 240V 3 Cast Iron – H 335 W 310 D 205mm 30kW 65A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL30/240/SS Direct Online Starter 240V 3 Cast Stainless Steel – H 335 W 310 D 205mm 30kW 65A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL30/415/AL Direct Online Starter 415V 3 Cast Aluminium – H 335 W 310 D 205mm 30kW 65A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL30/415/Cl Direct Online Starter 415V 3 Cast Iron – H 335 W 310 D 205mm 30kW 65A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL30/415/SS Direct Online Starter 415V 3 Cast Stainless Steel – H 335 W 310 D 205mm 30kW 65A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL4/240 Direct Online Starter 240V 3 Cast Iron – H 218 W 150 D 151mm 4kW 9A (AC3) 2x 1-6mm² for solid cable
2x 1-4mm² for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL4/415 Direct Online Starter 415V 3 Cast Iron – H 218 W 150 D 151mm 4kW 9A (AC3) 2x 1-6mm² for solid cable
2x 1-4mm² for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL5.5/240 Direct Online Starter 240V 3 Cast Iron – H 218 W 150 D 151mm 5.5kW 12A (AC3) 2x 1-6mm² for solid cable
2x 1-4mm² for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL55/240/AL Direct Online Starter 240V 3 Cast Aluminium – H 560 W 560 D 266mm 55kW 115A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL55/240/Cl Direct Online Starter 240V 3 Cast Iron – H 560 W 560 D 266mm 55kW 115A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL55/415/AL Direct Online Starter 415V 3 Cast Aluminium – H 560 W 560 D 266mm 55kW 115A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL55/415/Cl Direct Online Starter 415V 3 Cast Iron – H 560 W 560 D 266mm 55kW 115A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL7.5/240 Direct Online Starter 240V 3 Cast Iron – H 218 W 150 D 151mm 7.5kW 15A (AC3) 2x 1-6mm² for solid cable
2x 1-4mm² for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL7.5/415 Direct Online Starter 415V 3 Cast Iron – H 218 W 150 D 151mm 7.5kW 15A (AC3) 2x 1-6mm² for solid cable
2x 1-4mm² for flexible cable with ferrule
II 2 GD
Ex d IIB T6 Gb, Ex tb IIIC T85°C Db
DOL75/240/AL Direct Online Starter 240V 3 Cast Aluminium – H 560 W 560 D 266mm 75kW 150A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL75/240/Cl Direct Online Starter 240V 3 Cast Iron – H 560 W 560 D 266mm 75kW 150A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL75/415/AL Direct Online Starter 415V 3 Cast Aluminium – H 560 W 560 D 266mm 75kW 150A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL75/415/Cl Direct Online Starter 415V 3 Cast Iron – H 560 W 560 D 266mm 75kW 150A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL55/240/SS Direct Online Starter 240V 3 Cast Stainless Steel – H 560 W 560 D 266mm 55kW 115A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL55/415/SS Direct Online Starter 415V 3 Cast Stainless Steel – H 560 W 560 D 266mm 55kW 115A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL75/240/SS Direct Online Starter 240V 3 Cast Stainless Steel – H 560 W 560 D 266mm 75kW 150A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )
DOL75/415/SS Direct Online Starter 415V 3 Cast Stainless Steel – H 560 W 560 D 266mm 75kW 150A (AC3) 8 x 1.5 – 16mm² (2 x ground terminals)
6 x 0.5 – 4mm² (2 x ground terminals)
II 2 GD
Ex d IIB T5 Gb, Ex tb IIIC T82°C Db ( ta … +55°C )

Explosion Proof & Hazardous Area Electrical Equipment

Hazardous Area Electrical Distributors

Integrity | Knowledge | Reliability | Electrical HVAC Process Instrumentation Equipment

EXPERTS IN EQUIPMENT FOR EXPLOSIVE ATMOSPHERESExplosion Protection Ex d

Thorne & Derrick are leaders in the development and distribution of ATEX & IECEx Product Innovations that deliver significant improvements to clients plant, people and operational safety in the explosive atmosphere industries.

Your proactive problem solvers experienced in succession planning for the replacement of obsolete, non-conformant and legacy equipment in hazardous areas.

Your first-choice provider of innovative and competitive solutions to ensure ATEX & IECEx Compliance for Hazardous Area Electrical, HVAC & Process Instrumentation Equipment to UK and international projects.

Panels | Plugs | IsolatorsEnclosures | Lighting | Control Stations | Motor Starters | Call Points | Heat Trace | Gas Detection | Flame DetectionProcess InstrumentationProcess Heating | Fans | Locking

Hazardous Area Electrical Equipment

Competitive Prices | Extensive Stocks | Technical Support | Express Delivery