Flameproof LED Light Fittings | Hazardous Area Lighting Zone 1 & Zone 2 (21/22) | ATX FDLED

Appleton ATX FDLED Series Hazardous Area Lighting

Flameproof LED Light Fittings | Linear

Hazardous Area Lighting

Zone 1 & Zone 2 (21 & 22)

ATEX & IECEX Certified

Product Category: Hazardous Area Lighting | LED Light Fittings

FDLED Series Flameproof Luminaires, manufactured by Appleton ATXprovide hazardous area lighting for applications in petrochemical facilities, oil refineries, warehouses, manufacturing facilities, pulp and paper mills, water treatment and sewage facilities and underground tunnels. This range of flameproof lighting fittings with Ex d explosion protection can be installed in hazardous areas designated as Zone 1 and Zone 2 (Gas) – Zone 21 and Zone 22 (Dust) and are ideal for use in hazardous area locations where a high degree of corrosion resistance is required and for indoor or outdoor use where protection against dirt, water, dust and moisture is necessary.

Flameproof Appleton ATX LED lights are composed of a white powder coated galvanized steel (400 lm version) or aluminium (2400/4725 lm versions) with grey corrosion-resistant paint and an impact resistant borosilicate glass sealed tube.

The flameproof light fittings are supplied with an energy efficient electronic driver on a removable gear tray, one M20 blanking plug, an external and internal ground/earth connection and an O-ring for improved ingress protection (IP66/68).

Other features of these LEDs include:

  • Easy access to LED array through grey painted aluminum threaded entry cap
  • Easy connection to wire and disconnect with plug-in terminal blocks
  • Provide standard and emergency lighting in hazardous areas designated as Zone 1, 2, 21 and 22
  • The lighting units are entirely self-contained in a flameproof enclosure
  • LED light fixtures ensure optimal light dispersion to maximize usable light and enable you to work safely and comfortably
  • Fixtures are relentlessly tested to ensure they meet or exceed their rated capabilities in even the most extreme of conditions

FLAMEPROOF LED SPECIFICATIONS

  • ATEX/IECEx Certifications and Compliances: Zone 1 and 2 – 21 and 22; Ex II2GD; Ex d IIB (4725 lm version); Ex d IIB+H2 (2400 lm version); Ex d IIC (400 lm version); IK09 (400 and 2400 lm version); IK08 (4725 lm version); IP66/68
  • Electrical: 48/110/220 Vdc, 230 Vac, 50 Hz; 110 V to 254 V, 50/60 Hz
  • Lumens to Watts: 400 lumens is 6 Watts fluorescent, 2400 lumens is 23 Watts fluorescent, 4725 lumens is 46 Watts fluorescent
  • Ambient Temperatures: -30 °C to 60 °C (-22 °F to +140 °F)
  • Standard Materials and Finishes: Body is a combination of tempered borosilicate glass tube and aluminum end caps and cover. White powder coated galvanized steel (400 lm version) or aluminium (2400/4725 lm versions) internal reflector with Nitrile (NBR) O-ring gasket

 

LED Luminaires Ex d With Diffused Lens – Hazardous Area Lighting Appleton ATX Order Code
400lm – 6 Watts – 230V – 50Hz – 2 x M20 Cable Entries FDLED04AD2
2400lm – 23 Watts – 110/254V – 50/60Hz – 2 x M20 Cable Entries FDLED25BU2
4725lm – 46 Watts – 110/254V – 50/60Hz – 2 x M20 Cable Entries FDLED50BU2

Zone 1 Light Fittings LED ATEX Certified | Zone 2 Light Fittings LED ATEX Certified

➡ View our complete range of ATEX Lighting products for Zone 1 & Zone 2 (Zone 21 & 22) hazardous area lighting applications.

Dimensions and Fixing Points

Flameproof LED Light Fittings

Appleton ATX Product Code Type of Flameproof Light Fitting LED Lumen Output A B
FDLED04AD2 LED 400 lm 430 mm 335 mm
FDLED25BU2 LED 2400 lm 470 mm 375 mm
FDLED50BU2 LED 4725 lm 745 mm 650 mm

 

Hazardous Area Lighting

Our expert Hazardous Area Team can work with you to provide the best lighting solution for your facility | Thorne & Derrick

➡ See our technical resource section for further detailed information about hazardous area Zones and T-Class ratings.

ATEX & IECE x Hazardous Area Certifications and Compliances

ATEX

Flameproof Lighting

• Certification Type: Appleton ATX FDLED
— Gas: Zone 1 & Zone 2 Hazardous Areas
– Conforming to ATEX 94/9/CE: II 2 G
– Type of Explosion Protection: Ex d IIB (4725 lm version), Ex d IIB+H2 (2400 lm version), Ex d IIC (400 lm version)
– Temperature Class: T6
— Dust: Zone 21 & Zone 22 Hazardous Areas
– Conforming to ATEX ATEX 94/9/CE: II 2 D
– Type of Explosion Protection: Ex tb IIIC
– Surface Temperature: +75 °C (+167 °F) (400 lm version) +80 °C (+176 °F) (2400 and 4725 lm version)
• Ambient Temperature: -30 °C to 60 °C (-22 °F to +140 °F)
• CE Declaration of Conformity: 50312
• ATEX Certificate: INERIS 15 ATEX 0042X
• IECEx Certificate: IECEx INE 15.0046X
• Index of Protection according EN/IEC 60529: IP66/68

APPLETON ATX

Flameproof and Increased Safety electrical equipment certified by ATEX and IEC for Zone 1 & 2 (Gas) and Zone 21 & 22 (Dust) – this includes hazardous area lighting, plugs and sockets, junction boxes, panel boards, control stations and electrical enclosures for explosive atmospheres.

Hazardous Area Lighting Control Station Plug Junction Box

Lighting | Control Stations | Plugs & Sockets | Junction Boxes | Hazardous Area ATEX Certified Electrical Equipment for Explosive Atmospheres | Zone 1 & Zone 2

Data Sheets