Increased Safety Junction Boxes | Hazardous Area Zones 1 2 21 22 | Appleton ATX JBEL Series

Ex e Junction Boxes | Zone 1 & Zone 2 Junction Box Polycarbonate | Appleton ATX JBEL

Increased Safety Junction Boxes | Ex e |Appleton ATX JBEL Series

increased safety Junction Boxes

appleton atx jbel

Product Category: Junction Boxes | ATEX Certified | Zone 1 & Zone 2 Hazardous Areas

ATX JBEL Series, manufactured by Appleton ATX, are small, polycarbonate terminal, Increased Safety junction boxes designed to protect electrical connections within hazardous areas. The Increased Safety junction boxes provide Explosion Protection to ATEX Ex e standards and are manufactured with static and impact resistant polycarbonate.

They are available in two sizes and suitable for either unarmoured or armoured cable. The JBEL Series are ideal for use in Zone 1 and Zone 2 hazardous area environments where Increased Safety junction boxes with pillar type terminals are required to provide Ex e explosion protection. The JBEL range is also suitable for use in hazardous area Zone 21 or 22 areas, where flammable dusts are present either continuously or intermittently such as food processing, dairy, brewing and silos.

These Increased Safety junction boxes feature a pillar type terminal block for easy connection, ideal for use in both onshore and offshore, wet or corrosive atmospheres such as petroleum refineries, chemical refineries and other industrial process facilities with hazardous area locations according to ATEX or IECEx.

Appleton ATX JBEL

increased safety junction boxes

Specifications

  • Standard Materials and Finishes: Static and impact resistant polycarbonate enclosure with 316L grade stainless steel hardware and polyurethane cover gasket
  • Impact Resistance Rating: IK10
  • Ingress Protection Rating: IP66
  • Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
  • Operating Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
  • Zone 1 and Zone 2 Temperature Class: T6
  • Zone 21 and Zone 22 Surface Temperature: BJe1 (4mm²) – T75 °C (T167 °F) | BJe2 (10mm²) – T80 °C (T176 °F)
  • ATEX Certifications and Compliances: Zone 1 and 2 – 21 and 22; Ex II 2 GD ; IP66; IK10
  • Other Certifications: EURASEC and INMETRO

increased safety JUNCTION BOXes

Selection table

Increased Safety Junction Box 2,5/4 mm² – 660 V (BJe1)

Increased Safety Junction Box 2,5/4 mm² – 660 V Junction Box Layout Appleton ATX Order Code
4 x integrated cable glands for unarmored cable – 8-16 mm Appleton ATX JBEL1N4P16G
4 x M20 entries with earth brass continuity device Appleton ATX JBEL1A4M20

Increased Safety Junction Box 6/10 mm² – 690 V (BJe2)

Increased Safety Junction Box 6/10 mm² – 690 V Junction Box Layout Appleton ATX Order Code 
3 x M20 entries for unarmored cable with 3 cable glands Appleton ATX JBEL2N3M20G
4 x M20 entries for unarmored cable with 4 cable glands Appleton ATX JBEL2N4M20G
3 x M25 entries for unarmored cable with 3 cable glands Appleton ATX JBEL2N3M25G
4 x M25 entries for unarmored cable with 4 cable glands Appleton ATX JBEL2N4M25G
4 x M20 entries with earth brass continuity, with 2 x M20 plugs Appleton ATX JBEL2A4M20
4 x M25 entries with earth brass continuity, with 2 x M25 plugs Appleton ATX JBEL2A4M25

increased safety junction boxes

dimensions

Increased Safety Junction Boxes | Hazardous Area Zones 1 2 21 22 | Appleton ATX JBEL Series

Increased Safety Junction Boxes | Appleton ATX JBEL Series | Dimensions in mm (inches)

ATEX Certifications and Compliances

The following information relates to the hazardous area certification and approvals for this range of Increased Safety junction boxes for specification purposes – should you require any further information please contact Thorne & Derrick.

  • Certification Type BJe1
    Ex e

    Ex e Junction Boxes

    — Gas, Hazardous Area Zones 1 and 2:
    – Conforming to ATEX 94/9/CE: II 2 G
    – Type of Explosion Protection: Ex e II
    – Temperature Class: T6
    — Dust, Hazardous Area Zones 21 and 22:
    – Conforming to ATEX 94/9/CE: II2 D
    – Type of Explosion Protection: Ex tD A21
    – Surface Temperature: T75 °C (T167 °F)
    — Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
    — CE Declaration of Conformity: 50226
    — ATEX Certificate: LCIE 02 ATEX 6069

  • Hazardous Area Certification Type BJe2
    — Gas, Zones 1 and 2:
    – Conforming to ATEX 94/9/CE: II 2 G
    – Type of Explosion Protection: Ex e II
    – Temperature Class: T6
    — Dust, Zones 21 and 22:
    – Conforming to ATEX 94/9/CE: II2 D
    – Type of Explosion Protection: Ex tD A21
    – Surface Temperature: T80 °C (176 °F)
    — Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
    — CE Declaration of Conformity: 50209
    — ATEX Certificate: LCIE 99 ATEX 6003
  •  Index of Protection according EN/IEC 60529: IP66