Flameproof Thermostats | ATEX Zone 1 Zone 2 | EXHEAT FXT-DR FX-DI
EXHEAT FXT-DR & FX-DI Flameproof Thermostats
ATEX Thermostats | Zone 1 & Zone 2 (IIA, IIB, IIC) & Zone 21 & Zone 22 (IIIA, IIIB, IIIC)
EXHEAT FXT-DR & FX-DI
Flameproof Thermostats
EXHEAT FXT-DR and FXT-DI flameproof thermostats have been invented to administer temperature control for heaters as large as up to 2kW with the ability to perform in ambient temperatures as high as 195°C heating and air warming in Zone 1 and Zone 2 (Gas Groups IIA, IIB, IIC) and Zone 21 and Zone 22 (Dust Groups IIIA, IIIB, IIIC) explosive atmospheres according to ATEX Directive.
Designed specifically for frost protection, anti-condensation and temperature control the FXT-DR and FXT-DI thermostats can be connected with FX hazardous area compact enclosure heaters offering a single heating and control product.
Available as either a remote (FXT-DR) or inline (FXT-DI) thermostat and suitable for marine environments due to the design – housed in a hard anodised aluminium enclosure.
Features of EXHEAT FXT-DR & FX-DI Flameproof Thermostats
- Protection Method: Flameproof
- Voltage: 110 to 277VAC
- Temperature: Flameproof thermostat with temperature range -50°C to +195°C
- Temperature Class: T3 (T200°C) to T6 (T85°C)
- Cable: 3M standard (up to 10M available on request)
- Ingress Protection:Flameproof thermostat with IP66 rating
Flameproof Thermostats
ATEX Certification
Certification: ATEX/IECEx II 2 G D
Ex db IIC T6 to T3 Gb
Ex tb IIIC T85°C to T200°C Db
CU TR (EAC)
CU-TR.012/2011 CERTIFIED 1 Ex db IIC T6…T3 Gb X
Ex tb IIIC T85°C…T200°C Db X
CSA
Class I Div 1, Groups A, B C & D T6…T1
Class III, Div 1:Class II Div 1, Groups E, F & G. Type 4
Class I, Zone 1, AEx db IIC T6…T4 Class III, Zone 21:
Class II, Zone 21, AEx tb IIIC T85°C…T135°C IP66
FXT-DR DI Electrical Bonding Arrangement
Please download EXHEAT FXT-DR DI hazardous area thermostats O&M manual for full details on installation and maintenance procedures – this includes wiring diagrams, earth connection and pre installation inspection and checks.
FXT-DI and FXT-DR Flameproof Thermostats
Flameproof Thermostats
Applications
- Acoustic enclosures
- Condensation prevention
- Control/monitoring panels
- Control valve housings
- Fire hose cabinets
- Frost protection
- Generators
- Instrumentation cabinets
- Manifolds
- Motor enclosures
EXT-DI Flameproof Inline Thermostat & FXT-DR Flameproof Remote Thermostat – Dimensions
FXT-DR and FXT-DI
Flameproof Thermostats
Specification
EXHEAT Part Number | Open/Close Temperature (+/-3°C) | Voltage | Max Current | Temp Class | Max Ambient | Weight |
FXT-DI-5 | 16°C/5°C | 0-277V | 9.0 A | T6 T5 T4 T3 |
80°C 95°C 130°C 195°C |
0.5kg |
FXT-DI-20 | 26°C/15°C | |||||
FXT-DI-30 | 37°C/26°C | |||||
FXT-DI-40 | 53°C/42°C | |||||
FXT-DI-60 | 69°C/58°C | |||||
FXT-DI-80 | 92°C/81°C | |||||
FXT-DR-5 | 16°C/5°C | 0-277V | 9.0 A | T6 T5 T4 T3 |
80°C 95°C 130°C 195°C |
0.2kg |
FXT-DR-20 | 26°C/15°C | |||||
FXT-DR-30 | 37°C/26°C | |||||
FXT-DR-40 | 53°C/42°C | |||||
FXT-DR-60 | 69-130°C/58°C | |||||
FXT-DR-80 | 92°C/81°C |
Air Heaters | Immersion Heaters | Line Heaters | Thermostats | ATEX & IECEX Certified Electrical Heaters
T&D – Experts in Equipment for Explosive Atmospheres
Trust Thorne & Derrick to specify and supply from stock safe and reliable Heat, Light & Power Products for use in hazardous area locations and explosive atmospheres certified to international standards including ATEX and IECEx – this includes Zone 1 / Zone 2 (Flammable Gas) or Zone 21 / Zone 22 (Dusts) and Class I, Division 1 and Division 2 hazardous area requirements.
Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.
Lighting | Sockets | Glands | Control Stations | Isolators | Push Buttons | Hazardous Area Equipment UK & Export Sales