Wolf Airlamp Airturbo – Zone 1 & 2 Hazardous Area

Wolf Airlamp Airturbo - Zone 1 & 2 Hazardous Area

Wolf Airlamp Airturbo – Zone 1 & 2 Hazardous Area

wOLF

Hazardous Area Airlamps

Wolf A-0444 | Wolf A-0445

Airlamps for Zone 1, Zone 2 Hazardous Area Lighting 

Wolf Airturbo are airlamps for safe use in hazardous area for safe use in hazardous area Zone 1 & 2 (Gas, Vapour & Mist Explosive Atmospheres) – T&D are Approved Distributors for the Wolf Lighting including handlamps, torches, headtorches and floodlights.

Wolf Airturbo airlamps meet strict requirements of underground explosion proof lighting for coal mines and is BASEEFA certified for use in zones 1 and 2 hazardous areas. Mostly used in oil and petrochemicals industry for tank cleaning and pipeline inspections.

Once the Airturbo airlamps are connected to a suitable air supply, a continual output of high quality general lighting is produced, even under water. The lamp has a 15mm toughened glass lens for high impact strength and pressure resistance.

Housings of the airlamps are spark free cast brass with a forged brass safety hook, all nickel-plated. The generator is a compressed air driven turbo-alternator of simple design and robust construction and a gunmetal impulse turbine wheel produces the energy to power the 12v 55w Tungsten Halogen bulb.

Airlamps For Hazardous Areas

Wolf Airturbo airlamps provides reliable and versatile hazardous area lighting – the torches utilise tungsten halogen technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas atmospheres)  (IIA, IIB & IIC Groups) with T6 temperature classification. 

An overview of the Wolf Airturbo airlamps  to provide temporary lighting in explosive atmospheres range:

  • Wolf A-0444 Airturbo airlamp Zone 1
  • Wolf A-0445 Airturbo airlamp Zone 1
  • Certification: Ex s II T6
  • Hazardous Area: Zone 1 & 2 Gas Groups IIA, IIB & IIC
  • Temperature Classification (Gas) T6 | See more information about T Class Ratings

Wolf Airturbo airlamp

  • Safe Compressed Air Power
  • Reversed Air Safety Feature
  • Pressurised and Purged System
  • 55 Watt Long-life Halogen Bulb
  • Economical 0.25m3/min Consumption
  • Full Accessory Range Available
  • More Technical Information Hazardous Area Zones

AirLAMP

Zones 1 & 2 Hazardous Areas

  • Zone 1 & Zone 2 Gas

The Wolf Airturbo range are airlamps manufactured by Wolf Safety Lamp to provide lighting in Zone 1, Zone 2 hazardous areas – the tungsten halogen airlamps are for use in potentially explosive atmospheres.

Wolf Airturbo Airlamp

Wolf Airturbo Airlamp

Wolf Airlamp Airturbo Technical Information

The following table explains the technical specification differences for the Wolf Airturbo range of airlamps – should you require support or advice on selecting the correct hazardous area airlamp please do not hesitate to contact us.

Wolf ATEX Turbolite Part Reference Wolf A-0444 Wolf A-0445
Airlamp Description Safety Bay Lamp Compressed Air Powered Safety Floodlamp Compressed Air Powered
Hazardous Area Code Ex s II T6
Apparatus Standards  SFA 3009:1972
Area of Hazardous Classification (Gas) Zones 1 and 2, Gas Groups IIA, IIB and IIC
Temperature Classification  T6
Ambient Temperature -20ºC to +40ºC
ATEX Certificate BASEEFA Ex 78209X*
Enclosure Nickel Plated Brass and Gun-metal
Lens Ball Glass/Polycarbonate Dome Toughened Glass (15mm)
Beam Type All-around 360°C Illumination Flood (Matt Reflector) (as standard) or Spot (Polished Reflector) (to order)
Light Source Part Number Wolf A-1130
Type Tungsten Halogen Filament Bulb
Volts 12v
Watts 55w
Output 1000lm (at 12v)
Life 1000hrs (at 12v)
Power Source Type Compressed Air Driven Turbo-alternator
Air Pressure 4.0-8.0 bar
Consumption 0.25m3/min
Ingress Protection Once pressurised may be used underwater
Weight 8.2kg 12.5kg
*Special Certification Conditions  A clean, dry air supply must be used. Supply hose must be anti-static.

WOLF AIRLAMP AIRTURBO

Light Output & Product Dimensions

Wolf Airlamp Airturbo - Light Output

Wolf Airlamp Airturbo – Light Output

Wolf A-0444 – Ball Glass
Peak luminous intensity at 2.5m radius 2lux

Wolf A-0445 – Polished Reflector
Spot Beam (approx 4°)
Peak luminous intensity at 5m 900lux

Wolf A-0445 – Matt Reflector
Flood Beam (approx 30°)
Peak luminous intensity at 5m 40lux

Wolf Airlamp Airturbo - Product Dimensions

Wolf Airlamp Airturbo – Product Dimensions

Wolf - Hazardous Area Zone 1 & Zone 2 Handlamps, Headlamps, Torches & Floodlights (ATEX Certified)

Wolf Safety Lamp | Handlamps | Torches | Headtorches | Tank Lights | ATEX Hazardous Areas

Explosive Atmospheres

Electrical, Mechanical, Process & Instrumentation – Your Explosive Atmosphere Experts

Data Sheets