Wolf ATEX Flameproof Leadlamp – Zone 1 & Zone 2 Hazardous Area

Wolf ATEX Flameproof Leadlamp – Zone 1 & Zone 2 Hazardous Area
Wolf
Hazardous Area Leadlamps
Wolf LL-12 | Wolf LL-24 | Wolf LL-42 Â
Leadlamps for Zone 1, 2 Hazardous Area Lighting  Â
Wolf ATEX Flameproof are ATEX certified leadlamps for safe use in hazardous area Zone 1 & 2 (Gas, Vapour & Mist Explosive Atmospheres) – T&D are Approved Distributors for the Wolf Lighting including handlamps, torches, headtorches and floodlights.
Wolf ATEX Flameproof leadlamps are suitable for use in a wide range of explosive atmosphere applications such as cleaning, grit blasting and painting operations in tanks, silos and pipelines. The aluminium alloy construction ensures the lighting product is lightweight and portable and easy to carry for extended periods of time.
The Wolf leadlamp itself is constructed as a flameproof enclosure that contains a halogen bulb and switching & connecting wires.
The handle is moulded in tough high impact plastic and fitted with a cable clamp, and provides protection for the increased safety clamped cable terminals. Cables and plugs of the correct rating must be used and in explosive atmospheres ‘Ex’ component certified plugs, sockets and suitable fusing are required.
ATEX Leadlamps For Hazardous Areas
Wolf ATEX flameproof leadlamps provides reliable and versatile hazardous area lighting according to both ATEX Directive – the leadlamps utilise halogen technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas) with T4/T3 temperature classification.
ATEX Certified For Explosive Atmospheres Â
An overview of the Wolf ATEX flameproof leadlamp range to provide temporary lighting in explosive atmospheres:
- Wolf LL-12 Flood Beam Leadlamp Zone 1
- Wolf LL-24 Flood Beam Leadlamp Zone 1
- Wolf LL-42 Flood Beam Leadlamp Zone 1
- ATEX Certification: II 2 G EEx d e IIC T3/T4
- Hazardous Area Zone 1 & 2 Gas Groups IIA, IIB & IIC
- Temperature Classification (Gas) T4 (LL-12) T3 (LL-24, LL-42)
Wolf ATEX Flameproof LEADlamp

ATEX Leadlamps
- ATEX certified leadlamp complies with Directive 94/9/EC
- High output halogen light, up to 70 watts
- Lightweight alloy construction of leadlamp allows for single handed portability
- Zone 1 & 2, Gas group IIC T3/T4 certified
- Designed for quick and easy re-lamping and maintenance
- 12, 24 or 42 Volts models available
- Integral operation switch
- Oil resistant rubber guard for drop and impact protection
- Ideal for cleaning, grit blasting and painting operations
ATEX Certified LeadLAMP
Zones 1 & 2 Hazardous Areas
- Zone 1 & Zone 2 Gas
- See below table for ATEX Certification details including T-Rating, Gas Groups and Zone locations
The Wolf ATEX flameproof leadlamps are manufactured by Wolf Safety Lamp to provide lighting in Zone 1 and Zone 2 hazardous areas – the halogen leadlamps are for use in potentially explosive atmospheres according to the ATEX Directive.

Wolf ATEX Flameproof Leadlamp
Wolf ATEX Flameproof Leadlamp Technical Information
The following table explains the technical specification differences for the Wolf ATEX flameproof range of leadlamps – should you require support or advice on selecting the correct hazardous area leadlamps please do not hesitate to contact us.
Wolf ATEX Flameproof Part Reference | Wolf LL-12 | Wolf LL-24 | Wolf LL-42 | |
Product Designation | KHLE 70 EN | |||
Leadlamp Description | High Power Halogen Floodlight Leadlamp |
|||
Hazardous Area Code (ATEX & IECEx) | II 2 G EEx d e IIC T3/T4 | |||
Equipment Category | 2G | |||
Type of Protection | “d” flameproof, “e” increased safety |
|||
Area of Hazardous Classification (Gas) | Zones 1 and 2, Gas Groups IIA, IIB, IIC |
|||
Temperature Classification (Gas) | T4 | T3 | ||
Ambient Temperature | -20°C to +40°C | |||
ATEX Certificate | BVS 03 ATEX E 279 | |||
Enclosure | Light Alloy, High Impact Plastic, Oil Resistant Rubber |
|||
Lens | Toughened Glass | |||
Light Source | Wolf ATEX Flameproof Part Reference | Wolf LL-230 | Wolf LL-232 | Wolf LL-234 |
 Type | Halogen Filled Filament Bulb |
|||
Voltage | Â 12v | 24v | 42v | |
Watts | 55w | 70w | 65w | |
Beam | 100° Wide Angle Flood | |||
 Life | Up to 1000hrs | |||
Power Source | Â Insulation | Class lll | ||
Voltage | 12 Vac/dc | 24 Vac/dc | 42 Vac/dc | |
Weight | 2.5kg (excluding cable) | |||
Ingress Protection | IP54 minimum |
WOLF ATEX Flameproof LEADLAMP

Wolf ATEX Flameproof Leadlamp – Light Output
Light Output & Product Dimensions
Wolf LL-12 – 55w with Flood Beam (approx 100°) / Peak Luminous Intensity at 5m 180 lux
Wolf LL-24 – 70w with Flood Beam (approx 100°) / Peak Luminous Intensity at 5m 180 lux
Wolf LL-42 – 65w with Flood Beam (approx 100°) / Peak Luminous Intensity at 5m 180 lux

Wolf ATEX Flameproof Leadlamp – Product Dimensions

Wolf ATEX Flameproof Leadlamp for use in potentially explosive atmospheres and is CE marked to the ATEX Directive for safe use in zone 1 and 2 potentially explosive gas atmospheres.

Wolf Safety Lamp | Handlamps | Torches | Headtorches | Tank Lights | ATEX Hazardous Areas

Electrical, Mechanical, Process & Instrumentation – Your Explosive Atmosphere Experts