Wolf ATEX Flameproof Leadlamp – Zone 1 & Zone 2 Hazardous Area

Wolf ATEX Flameproof Leadlamp - Zone 1 & Zone 2 Hazardous Area

Wolf ATEX Flameproof Leadlamp – Zone 1 & Zone 2 Hazardous Area

Wolf

Hazardous Area Leadlamps

Wolf LL-12 | Wolf LL-24 | Wolf LL-42  

Leadlamps for Zone 1, 2 Hazardous Area Lighting   

Wolf ATEX Flameproof are ATEX certified leadlamps for safe use in hazardous area Zone 1 & 2 (Gas, Vapour & Mist Explosive Atmospheres) – T&D are Approved Distributors for the Wolf Lighting including handlamps, torches, headtorches and floodlights.

Wolf ATEX Flameproof leadlamps are suitable for use in a wide range of explosive atmosphere applications such as cleaning, grit blasting and painting operations in tanks, silos and pipelines. The aluminium alloy construction ensures the lighting product is lightweight and portable and easy to carry for extended periods of time.

The Wolf leadlamp itself is constructed as a flameproof enclosure that contains a halogen bulb and switching & connecting wires.

The handle is moulded in tough high impact plastic and fitted with a cable clamp, and provides protection for the increased safety clamped cable terminals. Cables and plugs of the correct rating must be used and in explosive atmospheres ‘Ex’ component certified plugs, sockets and suitable fusing are required.

ATEX Leadlamps For Hazardous Areas

Wolf ATEX flameproof leadlamps provides reliable and versatile hazardous area lighting according to both ATEX Directive – the leadlamps utilise halogen technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas) with T4/T3 temperature classification.

ATEX Certified For Explosive Atmospheres  

An overview of the Wolf ATEX flameproof leadlamp range to provide temporary lighting in explosive atmospheres:

  • Wolf LL-12 Flood Beam Leadlamp Zone 1
  • Wolf LL-24 Flood Beam Leadlamp Zone 1
  • Wolf LL-42 Flood Beam Leadlamp Zone 1
  • ATEX Certification: II 2 G EEx d e IIC T3/T4
  • Hazardous Area Zone 1 & 2 Gas Groups IIA, IIB & IIC
  • Temperature Classification (Gas) T4 (LL-12) T3 (LL-24, LL-42)

Wolf ATEX Flameproof LEADlamp

ATEX Leadlamps

ATEX Leadlamps

  • ATEX certified leadlamp complies with Directive 94/9/EC
  • High output halogen light, up to 70 watts
  • Lightweight alloy construction of leadlamp allows for single handed portability
  • Zone 1 & 2, Gas group IIC T3/T4 certified
  • Designed for quick and easy re-lamping and maintenance
  • 12, 24 or 42 Volts models available
  • Integral operation switch
  • Oil resistant rubber guard for drop and impact protection
  • Ideal for cleaning, grit blasting and painting operations

ATEX Certified LeadLAMP

Zones 1 & 2 Hazardous Areas

  • Zone 1 & Zone 2 Gas
  • See below table for ATEX Certification details including T-Rating, Gas Groups and Zone locations

The Wolf ATEX flameproof leadlamps are manufactured by Wolf Safety Lamp to provide lighting in Zone 1 and Zone 2 hazardous areas – the halogen leadlamps are for use in potentially explosive atmospheres according to the ATEX Directive.

Wolf ATEX Flameproof Leadlamp

Wolf ATEX Flameproof Leadlamp

Wolf ATEX Flameproof Leadlamp Technical Information

The following table explains the technical specification differences for the Wolf ATEX flameproof range of leadlamps – should you require support or advice on selecting the correct hazardous area leadlamps please do not hesitate to contact us.

Wolf ATEX Flameproof Part Reference Wolf LL-12 Wolf LL-24 Wolf LL-42
Product Designation  KHLE 70 EN
Leadlamp Description High Power Halogen
Floodlight Leadlamp
Hazardous Area Code (ATEX & IECEx) II 2 G EEx d e IIC T3/T4
Equipment Category  2G
Type of Protection “d” flameproof,
“e” increased safety
Area of Hazardous Classification (Gas) Zones 1 and 2,
Gas Groups IIA, IIB, IIC
Temperature Classification (Gas) T4 T3
Ambient Temperature -20°C to +40°C
ATEX Certificate BVS 03 ATEX E 279
Enclosure Light Alloy, High Impact Plastic,
Oil Resistant Rubber
Lens Toughened Glass
Light Source Wolf ATEX Flameproof Part Reference Wolf LL-230 Wolf LL-232 Wolf LL-234
 Type Halogen Filled
Filament Bulb
Voltage  12v 24v 42v
Watts 55w 70w 65w
Beam 100° Wide Angle Flood
 Life Up to 1000hrs
Power Source  Insulation Class lll
Voltage 12 Vac/dc 24 Vac/dc 42 Vac/dc
Weight 2.5kg (excluding cable)
Ingress Protection IP54 minimum

WOLF ATEX Flameproof LEADLAMP

Wolf ATEX Flameproof Leadlamp - Light Output

Wolf ATEX Flameproof Leadlamp – Light Output

Light Output & Product Dimensions

Wolf LL-12 – 55w with Flood Beam (approx 100°) / Peak Luminous Intensity at 5m 180 lux
Wolf LL-24 – 70w with Flood Beam (approx 100°) / Peak Luminous Intensity at 5m 180 lux
Wolf LL-42 – 65w with Flood Beam (approx 100°) / Peak Luminous Intensity at 5m 180 lux

Wolf ATEX Flameproof Leadlamp - Product Dimensions

Wolf ATEX Flameproof Leadlamp – Product Dimensions

Wolf ATEX Flameproof Leadlamp

Wolf ATEX Flameproof Leadlamp for use in potentially explosive atmospheres and is CE marked to the ATEX Directive for safe use in zone 1 and 2 potentially explosive gas atmospheres.

Wolf - Hazardous Area Zone 1 & Zone 2 Handlamps, Headlamps, Torches & Floodlights (ATEX Certified)

Wolf Safety Lamp | Handlamps | Torches | Headtorches | Tank Lights | ATEX Hazardous Areas

Explosive Atmospheres

Electrical, Mechanical, Process & Instrumentation – Your Explosive Atmosphere Experts

Data Sheets