Wolf ATEX Worklite Floodlights – Zone 1, 2, 21 & 22 Hazardous Area Floodlight
wOLF
Hazardous Area Floodlights
Wolf WL70 | Wolf WL-80 | Wolf WL-85
Floodlights for Zone 1, Zone 21, Zone 2, Zone 22 Hazardous Area Lighting
Wolf ATEX Worklite are ATEX certified floodlights for safe use in hazardous area Zone 1 & 2 (Gas, Vapour & Mist Explosive Atmospheres) and Zone 21 & 22 (Dust Explosive Atmospheres) – T&D are Approved Distributors for the Wolf Lighting including handlamps, torches, headtorches and floodlights.
Wolf ATEX Worklite are available in a stainless steel construction and is specifically designed for use in corrosive and arduous environments in industrial and offshore applications plus the battery and control circuit are within a box enclosure giving IP65 protection from ingress of dust and water jets.
The floodlight lamp has an anodised aluminium pivotable head that is IP65 sealed and designed as a heatsink for the LED light source, plus has an impact resistant 6mm toughened glass lens. In shot blasting and painting applications, the lens can be protected using a disposable antistatic lens guard (3 supplied).
Following the 2018 update, the Worklite™ now has:
- 3X The Light Output – up to 3,100 lumens at source
- 2X The Light Duration – up to 40 hours
- 4X The LED Life – designed to give 100,000+ hours
- IECEx Certification
ATEX Floodlights For Hazardous Areas
Wolf ATEX Worklite provides reliable and versatile hazardous area lighting according to ATEX Directive standards – the floodlights utilise LED technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas) and Zones 21 and Zones 22 dust atmospheres with T4 temperature classification.
ATEX & IECEx Certified For Explosive Atmospheres
An overview of the Wolf ATEX Worklite floodlight range to provide temporary lighting in explosive atmospheres:
- Wolf WL-70 ATEX Worklite Floodlight Zone 1
- Wolf WL-80 ATEX Worklite Floodlight Zone 1
- Wolf WL-85 ATEX Worklite Floodlight Zone 1
- ATEX Certification: II 2 GD II T4 (Tamb = 55°C) T135°C
- Hazardous Area Zone 1 & 2 Gas Groups IIA, IIB & IIC
- Temperature Classification (Gas) T4 | See more information about T Class Ratings
- Maximum Surface Temperature (Dust) 135ºC
- More Technical Information Hazardous Area Zones
Wolf ATEX Worklite floodlights
- ATEX approved floodlights for Zone 1 explosive gas and dust atmospheres
- High power white LED beam with flood of lower level fringe light
- LED light source ‘fitted for life’, no bulb replacement required
- Long duration, up to 12 hours full power, 24 hours half power
- Robust durable stainless steel construction
- Locking pivot head to direct light
- Toughened glass lens with optional disposable lens guard
- Rechargeable high capacity battery, fully managed
- State of charge LED indication
- Floodlight supplied with a mains charger with state of charge indication, powered from 100 to 254Vac
ATEX Certified Floodlights
Zones 1, 2, 21 & 22 Hazardous Areas
- Zone 1 & Zone 2 Gas
- Zone 21 & Zone 22 Dust
- See below table for ATEX Certification details including T-Rating, Gas Groups and Zone locations
The Wolf ATEX Worklite range are floodlights manufactured by Wolf Safety Lamp to provide lighting in Zone 1, Zone 2, Zone 21 or Zone 22 hazardous areas – the LED floodlights are for use in potentially explosive atmospheres according to the ATEX Directive.
Wolf ATEX Worklite Floodlights Technical Information
The following table explains the technical specification differences for the Wolf ATEX Worklite range of floodlight – should you require support or advice on selecting the correct hazardous area floodlight please do not hesitate to contact us.
Wolf ATEX Worklite Part Reference | Wolf WL-70 | Wolf WL-80 | Wolf WL-85 | ||||
Floodlights Description | High Power Rechargeable Battery Worklite 6 LED | High Power Rechargeable Battery Worklite 12 LED | |||||
Hazardous Area Code | II 2 GD II T4 (Tamb = 55°C) T135°C | ||||||
Type of Protection | ‘e’ Increased Safety, ‘ib’ Intrinsic Safety, ‘mb’ Encapsulation, tD Enclosure Protection | ||||||
Area of Hazardous Classification (Gas) | Zones 1 and 2, Gas Groups IIA, IIB, IIC | ||||||
Temperature Classification (Gas) | T4 | ||||||
Area of Hazardous Classification (Dust) | Zones 21 and 22 | ||||||
Maximum Surface Temperature (Dust) | T135°C | ||||||
Ambient Temperature | -20ºC to +40ºC | ||||||
ATEX Certificate | Sira07ATEX3027 | ||||||
Enclosure | Stainless Steel with Aluminium LED Lamp Head | ||||||
Lens | Toughened Glass Lens Supplied with 3 Anti-static Lens Guards | ||||||
Beam Type | Spot Beam with a Flood of Low Level Fringe Light | ||||||
Power Source | Part Number | Wolf W-218 | Wolf W-235 | ||||
Battery Type | Rechargeable Battery, Sealed Gel Lead Acid | ||||||
Volts | 12V | ||||||
Life | Up to 500 Recharge Cycles | ||||||
Capacity | 18Ah | 33Ah | |||||
Light Source | Type | High Power LED | |||||
Power / Output | 6 x 3 Watt LEDs / Up to 510 lm | 12 x 3 Watt LEDs / Up to 1020 lm | |||||
Bulb Life | 25,000hrs+ (Fitted for Life) | ||||||
Ingress Protection | IP65 to EN60529: 1992r | ||||||
Weight | 16kg | 16.5kg | 23kg | ||||
Charger Input | Yes | ||||||
Recharge Time | 8hrs | 12hrs |
WOLF ATEX WORKLITE FLOODLIGHTS
Light Output & Product Dimensions
Wolf WL-70
18W LED Beam (approx 30°)
Peak luminous intensity at 5m 120lux
Wolf WL-85 & Wolf WL-80
36W LED Beam (approx 30°)
Peak luminous intensity at 5m 210lux