Wolf WF-300 

Floodlights for Zone 1,2 Zone 21, 22 Hazardous Area Lighting

Wolf LinkEx LED Floodlites are ATEX certified temporary floodlights for safe use in hazardous area Zone 1 & 2 (Gas, Vapour & Mist Explosive Atmospheres) and Zone 21 & 22 (Dust Explosive Atmospheres) – T&D are Approved Distributors for the Wolf Lighting including handlamps, torches, headtorches and floodlights.

Wolf WF-300 LinkEx LED Floodlite is supplied with 10 metres of SY cable and fitted with an ATEX plug and runs with voltages of 100 to 254V AC or 18 to 54V AC/DC. For mains voltages it can also be fitted with an ATEX socket to setup a string of lights from a single power source.

The LinkEx LED Floodlite is constructed with a robust marine grade aluminium enclosure with corrosion resisting coating is ideal for harsh environments. The lens is a replaceable impact-resistant polycarbonate transparent cover, which can be protected using a disposable anti-static lens film and is sealed dust tight and protected from water immersion with a certified IP66/67 enclosure.

Supplied with a stainless steel (316 grade) bridle for pivot angle adjustment and bolted to a stainless steel stand for protection. The floodlite is fitted to a stainless steel bridle and stand which can be pivoted and can easily be detached and bolted to magnet fixings or a tripod stand.

ATEX Floodlight For Hazardous Areas

Wolf WF-300 floodlight provides reliable and versatile hazardous area lighting according to both ATEX Directive and IECEx standards – the floodlight utilise LED technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas) and Zones 21 and Zones 22 dust atmospheres (IIIA, IIIB & IIIC Groups) with T4 temperature classification.

ATEX & IECEx Certified For Explosive Atmospheres  

An overview of the Wolf ATEX WF-300 floodlight range to provide temporary lighting in explosive atmospheres:

  • Wolf WF-300 Spot Beam Floodlight Zone 1
  • ATEX Certification: II 2 GD Ex emb IIC T4 Gb / Ex t IIIC T87ºC Db IP66/67 (Ta = -20ºC to +55ºC) (18-54V AC/DC)
  • ATEX Certification: II 2 GD Ex emb IIC T4 Gb / Ex t IIIC T103ºC Db IP66/67 (Ta = -20ºC to +50ºC) (100-254V AC)
  • Hazardous Area Zone 1 & 2 Gas Groups IIA, IIB & IIC
  • Temperature Classification (Gas) T4 | See more information about T Class Ratings
  • Maximum Surface Temperature (Dust) 87ºC (18-54V AC/DC), 103ºC (100-254V AC)
  • More Technical Information Hazardous Area Zones

Wolf WF-300 Linkex LED Floodlite ATEX

ATEX Temporary Floodlights

ATEX Temporary Floodlights

  • ATEX Directive compliant floodlite and IECEx Scheme certified
  • For use in Zones 1 gas and 21 dust atmospheres
  • Ultra bright high power LED light output
  • Medium angle 30 degree flood beam
  • Wide voltage range 18-54V and 100-254V
  • Small, lightweight floodlamp construction
  • IP66/67 dust and watertight
  • Supplied with stainless steel stand and integral bridle
  • Very low maintenance
  • Magnet mounting and tripod options available
  • Lens protecting films available for blasting and painting applications

ATEX Certified Floodlite

Zones 1, 2, 21 & 22 Hazardous Areas

  • Zone 1 & Zone 2 Gas
  • Zone 21 & Zone 22 Dust
  • See below table for ATEX Certification details including T-Rating, Gas Groups and Zone locations

The Wolf WF-300 range are floodlight manufactured by Wolf Safety Lamp to provide lighting in Zone 1, Zone 2, Zone 21 or Zone 22 hazardous areas – the LED floodlight are for use in potentially explosive atmospheres according to the ATEX Directive.

Wolf LinkEx LED Floodlite ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf WF-300 LinkEx LED Floodlite ATEX

WOLF LinkEx LED Floodlite ATEX Technical Information

The following table explains the technical specification differences for the Wolf WF-300 floodlights – should you require support or advice on selecting the correct hazardous area floodlight please do not hesitate to contact us.

Wolf Part Reference Wolf WF-300
Floodlite Description LinkEx LED Floodlite
Voltage 18-54V AC/DC 100-254V AC
Hazardous Area Code (ATEX & IECEx) II 2 GD Ex emb IIC T4 Gb / Ex t IIIC T87ºC Db IP66/67 (Ta = -20ºC to +55ºC) II 2 GD Ex emb IIC T4 Gb / Ex t IIIC T103ºC Db IP66/67 (Ta = -20ºC to +50ºC)
Equipment Category 2GD
Type of Protection ‘e’ Increased Safety, ‘mb’ encapsulation, ‘t’ enclosure protection
Area of Hazardous Classification (Gas) Zones 1 & 2, Gas Group IIA, IIB, IIC
Temperature Classification (Gas) T4
Area of Hazardous Classification (Dust) Zones 21 and 22, Dust Groups IIIA, IIIB and IIIC
Maximum Surface Temperature (Dust) T87ºC T103ºC
Ambient Temperature -20ºC to +55ºC -20ºC to +55ºC
ATEX Certificate SIRA10ATEX5117X / IECExSIR10.0016X
Enclosure Marine Grade Aluminium Alloy, Epoxy Powder Coated
Lens Polycarbonate
Beam Type Medium Spot (Wide Flood Available – Special Order)
Light Source Type 48 x White High Power LED
Power 59W 58W
Output 5200lm
Life 100,000+ Hours (Fitted for Life)
Ingress Protection IP66/67
Weight 9.0kg (excluding cable)
Accessories Supplied with bridle and lamp stand

Wolf WF-300 Linkex LED Floodlite ATEX

Light Output & Product Dimensions

Wolf LinkEx LED Floodlite ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf LinkEx LED Floodlite ATEX – Light Output

Medium Flood (30°) (as per Light Output Diagram)
Light intensity at 2m 2870 lux, 5m 459 lux

Wide Flood (50°)

Wolf LinkEx LED Floodlite ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf LinkEx LED Floodlite ATEX – Product Dimensions

Wolf LinkEx LED Floodlite ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf LinkEx LED Floodlite ATEX – High performance, lightweight fully portable floodlight for hazardous area applications

Wolf - Hazardous Area Zone 1 & Zone 2 Handlamps, Headlamps, Torches & Floodlights (ATEX Certified)

Wolf Safety Lamp | Handlamps | Torches | Headtorches | Tank Lights | ATEX Hazardous Areas

Explosive Atmospheres

Electrical, Mechanical, Process & Instrumentation – Your Explosive Atmosphere Experts

Data Sheets