Wolf LinkEx LED Temporary Luminaire ATEX – Zone 1, 2, 21 & 22 Hazardous Area Leadlamp

Wolf LinkEx LED Temporary Luminaire ATEX - Zone 1, 2, 21 & 22 Hazardous Area Leadlamp

Wolf LinkEx LED Temporary Luminaire ATEX – Zone 1, 2, 21 & 22 Hazardous Area Leadlamp

Wolf

Hazardous Area LED Lead lamps

Wolf LX-400

Leadlamps for Zone 1,2 Zone 21, 22 Hazardous Area Lighting

Wolf LinkEx LED Temporary Luminaires are ATEX certified temporary lead lamps for safe use in hazardous area Zone 0,1 & 2 (Gas, Vapour & Mist Explosive Atmospheres) and Zone 20, 21 & 22 (Dust Explosive Atmospheres) – T&D are Approved Distributors for the Wolf Lighting including handlamps, torches, headtorches, leadlamps and floodlights.

The Wolf LinkEx LED Temporary Luminaires are lightweight, compact and highly robust with chemical resistance and are ideal for demanding environments. Units can be fitted with integral ATEX sockets allowing multiple lamps to be quickly and safely connected and positioned in a chain whilst energised.

The LED luminaires are available in two voltage input ranges: high voltage 85-264V AC for general applications and low voltage 19-28V AC/DC for use in confined space applications, such as metal tanks, with a higher risk of electric shock.

The wide input voltage ranges maximise usability and safety for chains of multiple lights or for long cable runs, where supply voltage can drop and a SOVI (Safe Operation Voltage Indicator) monitor showing when voltage is safe (within) or unsafe (outside of limits) is included.

ATEX Leadlamp For Hazardous Areas

Wolf LX-400 leadlamps provide reliable and versatile hazardous area lighting according to both ATEX Directive and IECEx standards – the luminaires utilise LED technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas) and Zones 21 and Zones 22 dust atmospheres (IIA, IIB & IIC Groups) with T4/T3 temperature classification.

ATEX & IECEx Certified For Explosive Atmospheres  

An overview of the Wolf ATEX LX-400 leadlamp range to provide temporary lighting in explosive atmospheres:

  • Wolf LX-400 Luminaire Zone 1
  • ATEX Certification: II 2 GD Ex emb IIC T3 Gb (-20ºC to +40ºC), Ex t IIIC T170ºC Db IP67 (Non Linkable)
  • II 2 GD Ex embd IIC T3 Gb (-20ºC to +40ºC), Ex t IIIC T170ºC Db IP66 (Linkable)
  • Hazardous Area Zone 1 & 2 Gas Groups IIA, IIB & IIC
  • Temperature Classification (Gas) T4 (LV) / T3 (HV) | see more information about T Class Ratings
  • Maximum Surface Temperature (Dust) 135ºC (LV) / 170ºC (HV)
  • More Technical Information Hazardous Area Zones

Wolf Linkex LED Temporary Luminaire ATEX

ATEX IECEX leadlamps

ATEX Temporary Luminaire

  • ATEX and IECEx luminaire certified for use in Zones 1 and Zones 2 explosive gas and dust atmospheres
  • High power, low maintenance LED light source ‘Fitted for Life’
  • High and low input voltage versions available
  • Incorporates unique SOVI (Safe Operation Voltage Indicator), monitor
  • Available with ATEX plugs and sockets to link in series/chain
  • Compact and robust design
  • Low power consumption
  • Wide range of fixing and mounting accessories available

ATEX Certified Luminaire

Zones 1, 2, 21 & 22 Hazardous Areas

  • Zone 1 & Zone 2 Gas
  • Zone 21 & Zone 22 Dust
  • See below table for ATEX Certification details including T-Rating, Gas Groups and Zone locations

The Wolf LX-400 range are luminaire manufactured by Wolf Safety Lamp to provide lighting in Zone 1, Zone 2, Zone 21 or Zone 22 hazardous areas – the LED luminaire are for use in potentially explosive atmospheres according to the ATEX Directive.

Wolf LinkEx LED Temporary Luminaire ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf LinkEx LX-400 LED Temporary Luminaire ATEX

WOLF LinkEx LED Luminaire ATEX Technical Information

The following table explains the technical specification differences for the Wolf LX-400 range of luminaires – should you require support or advice on selecting the correct hazardous area luminaires please do not hesitate to contact us.

Wolf Part Reference Wolf LX-400
Luminaire Description Low Voltage (LV) LinkEx LED Leadlamp High Voltage (LV) LinkEx LED Leadlamp
Voltage 18-54V AC/DC 100-254V AC
Hazardous Area Code (ATEX & IECEx) Non Linkable
II 2 GD Ex emb IIC T3 Gb (-20ºC to +40ºC), Ex t IIIC T170ºC Db IP67
Linkable
II 2 GD Ex embd IIC T3 Gb (-20ºC to +40ºC), Ex t IIIC T170ºC Db IP66
Type of Protection ‘e’ Increased Safety, ‘mb’ encapsulation, ‘d’ flameproof
Area of Hazardous Classification (Gas) Zones 1 & 2, Gas Group IIA, IIB, IIC
Temperature Classification (Gas) T3
Area of Hazardous Classification (Dust) Zones 21 and 22
Maximum Surface Temperature (Dust) T170ºC
Ambient Temperature -20ºC to +40ºC
ATEX Certificate SIRA12ATEX3117X / IECExSIR12.0070X
Enclosure & Lens Polycarbonate with Anti-Static Coating
Beam Type Wide Angle, Diffused Area Light
Light Source Type LED
Power 29W 32W
Output Up to 3250lm
Life Over 60,000+ Hours
Ingress Protection IP66/67
Input Voltage 19-28V AC/DC 85-264V AC
Weight (Non-Linkable) 3.0kg (excluding cable) 3.6kg (excluding cable)
Length (Non-Linkable) 0.7m
Included Supplied with lens protecting film and hanging films

WOLF Linkex LED Luminaire ATEX

Light Output & Product Dimensions

Wolf LinkEx LED Temporary Luminaire ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf LinkEx LED Temporary Luminaire ATEX – Light Output

180°
Peak Luminous Intensity at 2.5m 109 lux, at 5m 30 lux

360°
Peak Luminous Intensity at 2.5m 73 lux, at 5m 19 lux

Wolf LinkEx LED Temporary Luminaire ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf LinkEx LED Temporary Luminaire ATEX – Product Dimensions

Wolf LinkEx LED Temporary Luminaire ATEX - Zone 1, 2, 21 & 22 Hazardous Area Floodlight

Wolf LinkEx LED Temporary Luminaire ATEX – High power LED leadlamp for hazardous areas

Wolf - Hazardous Area Zone 1 & Zone 2 Handlamps, Headlamps, Torches & Floodlights (ATEX Certified)

Wolf Safety Lamp | Handlamps | Torches | Headtorches | Tank Lights | ATEX Hazardous Areas

Explosive Atmospheres

Electrical, Mechanical, Process & Instrumentation – Your Explosive Atmosphere Experts

Data Sheets