ATEX Doors | Dynaco S-555 Zone 2 & 22 High Speed Door – All Weather
ATEX Doors
Zone 2 & Zone 22 Hazardous Areas
High Speed Roll-up Door Certified & Approved According to ATEX – DYNACO S-555
Dynaco S-555 high speed roll-up ATEX doors are all weather doors suitable for use in outdoor hazardous area applications in Zone 2 (Gas) and Zone 22 (Dust) potentially explosive atmospheres – the high performance doors are approved and certified according to the ATEX Directive by the Apragaz notified body.
All metal parts of Dynaco S-555 hazardous area doors are made from corrosion resistant stainless steel whilst the non-metallic parts are composed of antistatic or electrical conductive materials – the construction of the doors ensures they avoid build up of static electricity that could led to a spark in flammable gas/dust environments, collectively referred to as hazardous area zones, according to the explosion risk defined by ATEX.
💡 STOP & CHECK – Are you compliant? Is your current high speed door an accident waiting to happen? There are many high speed doors installed which have been accepted as compliant because they have an ATEX certified motor. This does not even begin to mitigate the spark potential from such a piece of equipment. If you are concerned, please do not hesitate to contact T&D for advice.
Tutorial | Specifying Compliant ATEX Doors for Hazardous Areas & Explosive Atmospheres
Save Energy
Ask us to calculate your temperature losses and confirm the expected annual energy savings by installing high speed doors. Should you be interested to receive a FREE ROI REPORT to assess the energy efficiency impact Dynaco doors could have on your facility please contact us.
Benefits of Dynaco Doors
Explosive Atmospheres & Hazardous Area Locations & Workspaces
- Save Energy – reduced heat losses to buildings achived by superior sealing against air escape, draughts, humidity and loss of heat
- Fastest Door Cycle – Dynaco high speed doors limit heat loss and energy costs. 80% of energy losses are due to open time of the door
- Accident Forgiving & Self Reinserting – reduce costly repairs, avoid downtime interruptions due to blocked doors + damage to vehicles
- Reliability – few moving parts, reduced maintenance, lower operating costs and long service lifetime. >1million cycles = market leader
- Ultra Safe – the only 3rd party ATEX certified high speed flexible door available – soft bottom with edge detection reduces accidents
- Explosion Proof & Non-Sparking – high strength, corrosion-resistant stainless steel door structure + anti-static synthetic parts
- Wind Load Resistance – stable and secure up to wind load class 5, according to European standards EN12424
- Plant & Personnel Safety – flexible door curtain with no rigid elements improves Health & Safety with reduced site injuries + damages
- See also: ATEX Door Locks | Magnetic Locks for Security Control In Hazardous Areas
Crash Forgiving
Self Reinserting
The curtain automatically reinserts itself when dis-lodged. No repair costs, no production downtime.
ATEX Doors Dynaco S-555
Specifications
- Conforms To EN13241-1 – BS EN 13241-1 Product Standard for Powered Doors & Gates
- Conforms To ATEX Directive 2014/34/EU – Equipment for Potentially Explosive Atmospheres
💡 Handling Drums In Hazardous Areas? ➡
ATEX DOORS – TECHNICAL FEATURES
Edge detection via intrinsic safety barrier | Standard earthing kit | ATEX motor, gearbox and encoder |
Complete structure in stainless steel | All synthetic parts in antistatic material | Side reinforcement |
Dynaco S-555 Doors
Technical Specification
Maximum Dimensions | W 5.500 mm x H 5.500 mm |
Opening Door Speed Closing Door Speed |
Maximum 1 m/s 1 m/s |
Structure | Stainless steel: 80 x 40 x 3 mm. |
Drum | Stainless steel – Ø 102 x 1.2 mm. |
Side Guides | Reinforced antistatic polyethylene (PEUHMW1000 carbon black) on springs. Side guides reinforced over the total height. |
Electric Motor | 4 poles, without brake. Ex d Power 1,5 kW – IP rating: IP 66 |
Control Box | DYNALOGIC 2 (600x600x210mm) provided with: circuit breaker, general divider, adjustable timer, push button for opening and reset, emergency stop and Ex i switching amplifier. IP rating: IP 65. Frequency inverter. Always to be installed outside the danger zone. Optional: DYNALOGIC 5 (500x500x250mm). |
Standard Detectors | Ex ia infrared barrier: 300 mm from the floor. Bottom edge detection via intrinsic safety barrier |
Power Supply Frequency |
Single phase 230V – 16 A Frequency: 50-60 Hz |
Available Colours Comparable with: | Black RAL9005 (Actual colour may deviate. Colour sample available upon request) |
Zone 22 Explosive Dust atmospheres
Zone 22 is defined as a “hazardous atmosphere formed by a dust cloud that is not likely to occur in normal operation and if so, only for a short period of time. Accumulations and layers of combustible dusts are present.” As part of explosion protection measures for, it is critical that prevention and mitigation against risk form the basis of a safe working environment. Preventing an explosive dust cloud from occurring is the primary method but this cannot always be achieved. The next step is to remove ignition sources such as electrical and non-electrical devices, hot surfaces and electrostatic discharges. Further mitigation measures may include partial inerting, isolating (making sections), venting and good housekeeping. Equipment used within such areas should be certified in line with the ATEX directive.
Potentially explosive atmospheres in the food industry include flour mills and the logistics and storage warehouses for custard powder, instant coffee, sugar, dried milk, potato powder and soup powder – including Zones 1 (21) and Zones 2 (22) we can assist with the upgrade of traditional fluorescent to modern technology brilliant white-light LED hazardous area lighting systems.
EN13241-1 STANDARDS
Reference | Standard | Test acc. | Results |
Water permeability | EN 12425 | EN 12489 | Class 3 |
Wind load | EN 12424 | EN 12444 | Class 4* |
Wind permeability | EN 12426 | EN 12427 | Class 1** |
Safe openings | EN 12453 | EN 12445 | Pass |
Mechanical resistance | EN 12604 | EN 12605 | Pass |
Unintended movements | EN 12604 | EN 12605 | Pass |
Thermal transmittance | EN 12428 | EN 12428 | 6,02 W/m²K |
Performance (cycles) | EN 12604 | EN 12605 | NPD |
The indicated class for wind resistance applies for maximum dimensions.
* For doors up to W 5.000mm x H 5.500mm: Class 5
** Valid for a door of 3500 x 3500mm
ATEX Directive 2014/34/EU
II 3 G/D
Ex h IIC T6 EPL Gb
Ex h IIIC 85°C EPL Db
Ex db mc ia e IIC T4 EPL Gc
Ex tb mc tD IIIB 135°C EPL Dc
CE 0029 APRAGAZ 16ATEX 0150X/1
T ambient -10°C to 45°C
Dynaco S-555 Dimensions & Installation Requirements
All indicated dimensions are net: the space necessary for mounting and maintenance has to be provided. Reduced dimensions: upon request. Please Note: Based on the risk analysis of the environment, extra push buttons, detectors and covers might be required.
ATEX Doors Product Overview
The Dynaco range of High Speed Roll-up Doors include options for interior and exterior applications for use in explosive gas and dust atmospheres. An overview and certification details can be found below. Refer to individual door product pages for full specification details.
ZONE 1 & 21 ATEX DOOR – ALL WEATHER |
ZONE 1 & 21 ATEX DOOR – POWER |
ZONE 1 & 21 ATEX DOOR – COMPACT |
S-559 is suitable for use in Zone 1 and Zone 21 explosive atmospheres and is specifically designed for outdoor use. The ATEX door is wind resistant up to wind load class 5. | S-549 is suitable for use in Zone 1 & Zone 21 explosive atmospheres. The ATEX door is designed for outdoor use and is wind resistant up to wind load class 4. | S-539 is suitable for use in Zone 1 & Zone 21 explosive atmospheres and is specifically designed for hazardous area indoor applications. |
|
|
|
ZONE 2 & 22 ATEX DOOR – ALL WEATHER |
ZONE 2 & 22 – ATEX DOOR – POWER |
ZONE 2 & 22 – ATEX DOOR – COMPACT |
S-555 is suitable for use in Zone 2 & 22 explosive atmospheres and is specifically designed for outdoor use. The ATEX door is wind resistant up to wind load class 5.
|
S-545 is suitable for use in Zone 2 & 22 explosive atmospheres. The ATEX door is designed for outdoor use and is wind resistant up to wind load class 4.
|
S-535 is suitable for Zone 2 & Zone 22 explosive atmospheres and is specifically designed for hazardous area indoor applications.
|
Experts in Equipment for Explosive Atmospheres
➡ All Thorne & Derrick Sales Engineers hold CompEx Certificates (Hazardous Awareness Course EX F) and undertake advanced and ongoing Explosion Protection training with all suppliers – we can be safely trusted to specify and supply Access Control, Security & Entrance Automation Products for use in hazardous areas zones and explosive atmospheres.
➡ Browse more from our ATEX Doors range manufactured by Dynaco.
EMBED FLIPBOOK