11kV Enclosure – Hv High Voltage Junction Box Zone 1 & Zone 2 Hazardous Area ATEX

View Sub Products

High Voltage Junction Box 33kV-45kV - Zone 1 Zone 2 Hazardous Area ATEX

HV Enclosures & Junction Boxes Up to 45kV

Abtech HVJB high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution for 11kV systems up to 1000sqmm cables offering flexibility over the choice of cables, entries and cable terminations – ATEX certified for Zone 1 and Zone 2 connection of HV cables in hazardous area locations.

11kV enclosure is suitable for low temperature applications and is DTS deluge tested.

Abtech HVJB high voltage (HV) cable junction boxes are manufactured from 316L stainless steel with a silicon gasket and stainless steel fasteners. The enclosure also features heavy duty machined hinges with lift off cover pad-lockable cover and has an orbital finish but painted and electro-polished options also available.

High Voltage HV Junction Box

Zone 1 & Zone 2 Hazardous Area

ATEX Certified

Abtech HVJB

Abtech HVJB High Voltage Hazardous Area Electrical Enclosures

HV Junction Boxes Manufactured From 316 Stainless Steel For 11kV High Voltage Cable Connections & Terminations

Abtech HVJB High Voltage Hazardous Area Electrical Enclosures

Abtech HVJB High Voltage Hazardous Area Electrical Enclosures

Abtech HVJB High Voltage Hazardous Area Electrical Enclosures

11kV Enclosure – Hv High Voltage Junction Box Zone 1 & Zone 2 Hazardous Area ATEX

High Voltage Junction Box 11kV - Zone 1 Zone 2 Hazardous Area ATEX

Abtech HVJB General Arrangement HV Enclosure Drawing – cable termination, enclosure and junction box suitable for jointing, connecting and terminating HV cables 11kV

Abtech HVJB High Voltage Hazardous Area Electrical Enclosures - Models

Abtech HVJB High Voltage Hazardous Area Electrical Enclosures – Models

Abtech Part RefWidth (mm) DimensionHeight (mm) DimensionDepth (mm)Power Rating (W)  @  T4 (W)**Maximum Voltage (kV) Maximum  Current  (A) Maximum  Conductor  Size  (sqmm) Hazardous Area Enclosure
HVJB73(x‐x)650950300259/129.511 kV9801000sqmm*** Zone 1 & Zone 2
HVJB83(x‐x)8001250300346/17311 kV9801000sqmm Zone 1 & Zone 2
HVJB84(x‐x)8001250300346/17311 kV9801000sqmm Zone 1 & Zone 2

* (x‐x) demotes the number of connectors per phase, 1st position = top, 2nd position = bottom.  For example: HVJB73(2‐1) = 2 x conductors per  phase top entry and 1 x conductor per phase bottom entry.  ** Power rating is determined by ambient temp range: ‐20 to +400C / ‐50 to +550C respectively. The higher power rating can also be achieved if the enclosure is marked Ex e IIC T1500C Gb.  *** For cables greater then 300mm2, it is advisable to use the HVJB8 size enclosure.

Hazardous Area Certification

High Voltage Enclosures & Junction Boxes (HV) - Hazardous Area

High Voltage Enclosures & Junction Boxes (HV) – Hazardous Area

  • ATEX EEx e (Zone 1 & Zone 2) to BS EN 60079-7
  • NEMA 4X (CSA, UL & FM) Class 1 Division 2
  • Deluge Tested To DTS-01

Zone 1 & 21, Gas and Dust / Class 1 Div 2 / EAC (TR‐CU)

Type Of Explosion Protection – Ex e (Increased Safety), Ex tb (Dust Protected)

Apparatus Hazardous Area Coding – ATEX Ex e IIC T4 Gb, Ex tb IIIC T70°C Db / Ex e IIC T150°C Gb, Ex tb IIIC T110°C Db

Temperature Rating

  • Standard: -20° to +40°C (-4° to 104°F)
  • Option: -50° to +65°C (-58° to 149°F)

High Voltage HV ENCLOSURE Specification

  • Electrical Enclosure Type – High Voltage (HV)
  • Ingress Protection – IP66/67 to EN60529, Type 4X, DTS‐01
  • Material – 2mm 316L Stainless Steel (EN 1.4404) enclosure with orbital finish, silicone gasket and  captive 316 stainless steel fasteners, 3mm 316L (EN 1.4404) Stainless Steel gland plates
  • Ambient Temperature Rating -‐20°C to +40°C or ‐50°C to +55°C (refer to certificate)
  • Maximum Number Of HV Cable Terminations – 3 conductors per phase in & 3 conductors per phase out
  • Number Of HV Cable Gland Plates – Dependant upon configuration
  • Crimp Lugs – 6sqmm to 1000sqmm
  • Connector Size – 6sqmm to 150sqmm For 4 Way 35sqmm To 240sqmm For 3 Way
  • Earthing – Via Studs On Electrical Enclosure, Door & Cable Gland Plates
  • Mounting – Via 3mm Thick External Mounting Straps, Slotted Upper Strap for Ease Of Installation

ENCLOSURE Options

  • ACH  Anti‐condensation heater (dependent upon available internal dimensions)
  • EP  Electro‐polished
  • PS  Epoxy powder coated, smooth finish (RAL colour may be specified)
  • PT  Epoxy powder coated, Hammer Grey
  • BPG  Single core terminal box mounted internally
  • CP  Internal access protection cover plate
  • MB  Mounting boss for eye bolts

Add the required suffix to the product reference.    Example: HVJB73(0‐3)BPG = HVJB 7, 3‐ way with 3 entries in bottom and internal terminal box

MV HV electrical Enclosures & Junction Boxes
3.3kV 6.6kV 11kV 33kV HIGH VOLTAGES

T&D produce customised HV Junction Boxes & Electrical Enclosures suitable for safe installation and distribution of MV-HV electrical power in hazardous area locations – enclosures and junction boxes can be specified and supplied for 3.3kV, 6.6kV, 11kV and 33kV high voltage power networks where Ex-certified HV electrical equipment is required in accordance with ATEX and IECEx hazardous area certification.

HV High Voltage Electrical Enclosures Junction Boxes

HV High Voltage Specialists – Zone 1 & Zone 2 Hazardous Area Certified By ATEX

➡ View complete range: HV Junction Boxes & Electrical Enclosures

HV Enclosures Junction Boxes

MV-HV Junction Boxes & Electrical Enclosures For 3.3kV, 11kV and 33kV Medium-High Voltage Networks – Industrial & Hazardous Area