Hazardous Area Convector Heaters | ATEX Zone 1 Zone 2 Heaters | EXHEAT FCR

EXHEAT Hazardous Area Air Warmers ATEX & IECEx
ATEX Air Warmer | Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas
Hazardous Area Air Warmers
ATEX Certified
Zone 1 & Zone 2 Convector Heaters for Hazardous Area Heating
EXHEAT FCR hazardous area convector heaters provide increased safety (Ex e), hazardous area certified heating and air warming of Zone 1 & Zone 2 (Flammable Gas) hazardous areas and explosive atmospheres according to ATEX Directive.
The EXHEAT FCR offers an exceptionally long life thanks to the finned stainless steel elements and heavy duty folded steel construction. The FCR range of convector heaters can be provided with temperature ratings of T2, T3 and T4 (T Classes) and is suitable for ambient temperatures from -60°C to +40°C.
EXHEAT FCR hazardous area convector heaters are certified to meet ATEX equipment directive and IECEx standards and are suitable for wall or floor mounting with an optional room temperature control thermostat.
Features of EXHEAT FCR Convector Heaters
- Hazardous Area Certification to ATEX, IECEx and CUTR (EAC) standards
- Lightweight – convector heater enclosure certified weatherproof to IP67
- Small footprint, occupying less floor space suitable for smaller spaces
- Sloped top, stopping objects being placed on the grill
- Installation – suitable for horizontal floor or wall mounting convector heaters in hazardous areas
- Convector heaters with integral terminal enclosure
- Suitable for ambient temperatures from -60°C to +40°C for safe heating in explosive atmospheres
- Incoloy 800 finned elements for long life
- Grey gloss, powder coated, sheet steel construction
- Options – built-in room temperature control thermostat
- Cable – 2 × M20 (temporary plugged) cable entry provided as standard
EXHEAT FCR
Hazardous Area Convector Heaters
ATEX Certification & Installation

Hazardous Area Convector Heaters For Zone 1 Zone 2 Hazardous Areas
Certification: ATEX / IECEx II 2 G
Ex e IIC T3…T2 Gb Zone 1 and 2 (IP67)
CU TR (formerly GOST)
ATEX / IECEx II 2 G
Ex e IIC T3…T2 Gb Zone 1 and 2 (IP67)
CU TR (EAC)
1Ex e II T4…T2 Gb
CSA
Approval upcoming
FCR General Arrangement
Please download EXHEAT FCR convector heaters O&M manual for full details on installation and maintenance procedures – this includes wiring diagrams, earth connection and pre installation inspection and checks.
Heater Power Rating | Standard heating ratings 1kW, 2kW and 3kW |
Enclosure | Heavy duty powder coated mild steel |
Controls | If required, the heaters can be controlled from the EXHEAT Industrial range of remote mounted thermostats available for use in hazardous areas |
Mounting | Wall or floor mounting via brackets/feet supplied |
Voltage | 1 phase: 110V to 120V and 230V to 254V 3 phase: 380V to 440V, subject to design parameters |
EXHEAT FCR
EXHEAT FCR Hazardous Area Convector Heaters – Applications
Applications for these electric heaters include:
EXHEAT Stockist – Worldwide Delivery, Competitive Quotations
- Spray booths
- Aircraft hangers
- Offshore installations
- Battery stores
- Gas installations
- Container heating
- Storage areas
- Frost protection
Please download EXHEAT FCR hazardous area air warmers O&M manual for full details on installation and maintenance procedures – this includes wiring diagrams, earth connection and pre installation inspection and checks.
EXHEAT FCR Hazardous Area Convector Heaters
Product Range
These air warmers are suitable for Zone 1 & Zone 2 (IIA, IIB, IIC) gas groups according to ATEX | IECEx Directive.
Convector Heater Model | T Class | Hazardous Area | Watts Rating | Voltage | Weight (Kg) |
EXHEAT FCR 1 | T2-T4 | Zone 1 & Zone 2 | 1.0 | 240 | 17 |
EXHEAT FCR 1/110 | T2-T4 | Zone 1 & Zone 2 | 1.0 | 110 | 17 |
EXHEAT FCR 2 | T2-T4 | Zone 1 & Zone 2 | 2.0 | 240 | 32 |
EXHEAT FCR 2/110 | T2-T4 | Zone 1 & Zone 2 | 2.0 | 110 | 32 |
EXHEAT FCR 3 | T2-T4 | Zone 1 & Zone 2 | 3.0 | 240 | 47 |
EXHEAT FCR 3/145 | T2-T4 | Zone 1 & Zone 2 | 3.0 | 415/3 | 47 |
EXHEAT FCR Hazardous Area Convector Heaters – Dimensions
EXHEAT FCR Hazardous Area Convector Heaters
EXHEAT Part Number | Load (kW) | Voltage (V) | Weight (kg) | Dim A (mm) |
Convector Heaters Ex e II T3 | ||||
FCR 1110 | 1 | 110 | 17 | 1240 |
FCR 110A | 1 | 110 | 19 | 1295 |
FCR 1240 | 1 | 240/415 | 17 | 1240 |
FCR 1240A | 1 | 240 | 19 | 1295 |
FCR 2110 | 2 | 110 | 32 | 1240 |
FCR 2110A | 2 | 110 | 34 | 1295 |
FCR 2240 | 2 | 240/415 | 32 | 1240 |
FCR 2240A | 2 | 240 | 34 | 1295 |
FCR 3240 | 3 | 240/415 | 47 | 1750 |
FCR 3240A | 3 | 240 | 49 | 1805 |
Air Heaters | Immersion Heaters | Line Heaters | Thermostats | ATEX & IECEX Certified Electrical Heaters
T&D – Experts in Equipment for Explosive Atmospheres
Trust Thorne & Derrick to specify and supply from stock safe and reliable Heat, Light & Power Products for use in hazardous area locations and explosive atmospheres certified to international standards including ATEX and IECEx – this includes Zone 1 / Zone 2 (Flammable Gas) or Zone 21 / Zone 22 (Dusts) and Class I, Division 1 and Division 2 hazardous area requirements.
Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.
Lighting | Sockets | Glands | Control Stations | Isolators | Push Buttons | Hazardous Area Equipment UK & Export Sales