Hazardous Area Convector Heaters | ATEX Zone 1 Zone 2 Heaters | EXHEAT FCR

EXHEAT Hazardous Area Air Warmers ATEX & IECEx

EXHEAT Hazardous Area Air Warmers ATEX & IECEx

ATEX Convector Heater

Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas

Hazardous Area Air Warmers

ATEX Certified

Zone 1 & Zone 2 Convector Heaters for Hazardous Area Heating

EXHEAT FCR hazardous area convector heaters provide intrinsically safe, hazardous area certified heating and air warming for Zone 1 and Zone 2 hazardous areas.

The EXHEAT FCR offers an exceptionally long life thanks to the finned stainless steel elements and heavy duty folded steel construction. The FCR range can be provided with temperature ratings of T2, T3 and T4 and is suitable for ambient temperatures from -60°C to +40°C.

EXHEAT FCR hazardous area convector heaters are certified to meet ATEX equipment directive and IECEx standards and are suitable for wall or floor mounting with an optional room temperature control thermostat.

 

EXHEAT FCR Hazardous Area Convector Heaters

ATEX Certification & Installation

Hazardous Area Convector Heaters For Zone 1 Zone 2 Hazardous Areas

Hazardous Area Convector Heaters For Zone 1 Zone 2 Hazardous Areas

Certification: ATEX / IECEx    II 2 G
Ex e IIC T2 to T4 Gb Zone 1 and 2
CU TR (formerly GOST)

Prior to installing the EXHEAT FCR hazardous area convector heaters a visual inspection must be carried out and the heater must be checked to ensure the insulation resistance reading is above 2MΩ per element at 500 volts dc.

If the heater fails this test the power and control circuits must be isolated.

To install the heater carefully remove from the packaging and check for damage. The convector heater should be fixed into place using the pre-drilled holes and all terminal connections checked for tightness prior to energising.

The appliance must be securely fitted to a wall or floor using only the brackets provided and the orientation of the heaters must be strictly adhered to with the feet facing down at all times.

EXHEAT FCR Hazardous Area Convector Heaters – Applications

EXHEAT

EXHEAT Stockist – Worldwide Delivery, Competitive Quotations

  • Aircraft hangers
  • Fuel servicing areas
  • Chemical plants
  • Offshore installations
  • Battery stores
  • Gas installations
  • Container heating
  • Storage areas
  • Frost protection

EXHEAT FCR Hazardous Area Convector Heaters Product Range

Suitable for Zone 1 & Zone 2 (IIA, IIB, IIC) gas groups.

Convector Heater ModelT ClassHazardous AreaWatts RatingVoltageWeight (Kg)
EXHEAT FCR 1T2-T4Zone 1 & Zone 21.024017
EXHEAT FCR 1/110T2-T4Zone 1 & Zone 21.011017
EXHEAT FCR 2T2-T4Zone 1 & Zone 22.024032
EXHEAT FCR 2/110T2-T4Zone 1 & Zone 22.011032
EXHEAT FCR 3T2-T4Zone 1 & Zone 23.024047
EXHEAT FCR 3/145T2-T4Zone 1 & Zone 23.0415/347

EXHEAT FCR Hazardous Area Convector Heaters - Dimensions

EXHEAT FCR Hazardous Area Convector Heaters – Dimensions

Hazardous Area ELECTRICAL, MECHANICAL, PROCESS & INSTRUMENTATION Specialists

Hazardous Area Zone 1 Zone 2 ATEX Certified - Brands

Thorne & Derrick International distribute Electrical, Mechanical, Process & Instrumentation Equipment to the global hazardous area industries and are approved vendors to most leading oil, gas and petrochemical companies and their EPC’s.

T&D supply ATEX & IECEx Certified equipment for the detection, metering, flow measurement and heat tracing of potentially explosive gases in hazardous areas Zone 1 and Zone 2.

Hazardous Area - Gas Detection, Metering, Lighting & Flow Measurement

 

➡ Did you know?  T&D have a dedicated Exports and Hazardous Area Sales Team, send an enquiry.

➡ Did you know? T&D are Thermon, The Heat Tracing Specialists, largest UK stockist.

 Did you know? T&D are Trained by Crowcon in the specification and sale of Gas Detectors.