ATEX Air Warmer | Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas

Hazardous Area Air Warmers

ATEX Certified

Zone 1 & Zone 2 Convector Heaters for Hazardous Area Heating

EXHEAT FCR hazardous area convector heaters provide intrinsically safe, hazardous area certified heating and air warming Zone 1 & Zone 2 (Flammable Gas) hazardous areas and explosive atmospheres according to ATEX Directive.

The EXHEAT FCR offers an exceptionally long life thanks to the finned stainless steel elements and heavy duty folded steel construction. The FCR range of convector heaters can be provided with temperature ratings of T2, T3 and T4 (T Classes) and is suitable for ambient temperatures from -60°C to +40°C.

EXHEAT FCR hazardous area convector heaters are certified to meet ATEX equipment directive and IECEx standards and are suitable for wall or floor mounting with an optional room temperature control thermostat.

Features of EXHEAT FCR Convector Heaters

  • Hazardous Area Certification  to ATEX, IECEx and CUTR (EAC) standards
  • Lightweight – heater enclosure is certified weatherproof to ingress protection IP67
  • Small footprint, occupying less floor space suitable for smaller spaces
  • Sloped top, stopping objects being placed on the grill
  • Installation – suitable for horizontal floor or wall mounting in hazardous areas
  • Integral terminal enclosure
  • Suitable for ambient temperatures from -60°C to +40°C
  • Incoloy 800 finned elements for long life
  • Grey gloss, powder coated, sheet steel construction
  • Options – built-in room temperature control thermostat
  • Cable – 2 × M20 (temporary plugged) cable entry provided as standard

EXHEAT FCR Hazardous Area Convector Heaters

ATEX Certification & Installation

Hazardous Area Convector Heaters For Zone 1 Zone 2 Hazardous Areas

Hazardous Area Convector Heaters For Zone 1 Zone 2 Hazardous Areas

Certification: ATEX / IECEx  II 2 G
Ex e IIC T3…T2 Gb Zone 1 and 2 (IP67)
CU TR (formerly GOST)

ATEX / IECEx   II 2 G
Ex e IIC T3…T2 Gb Zone 1 and 2 (IP67)

CU TR (EAC)
1Ex e II T4…T2 Gb

CSA
Approval upcoming

Heater Power RatingStandard heating ratings 1kW, 2kW and 3kW
EnclosureHeavy duty powder coated mild steel
ControlsIf required, the heaters can be controlled from the EXHEAT Industrial range of remote mounted thermostats available for use in hazardous areas
MountingWall or floor mounting via brackets/feet supplied
Voltage1 phase: 110V to 120V and 230V to 254V
3 phase: 380V to 440V, subject to design parameters

Prior to installing the EXHEAT FCR hazardous area convector heaters a visual inspection must be carried out and the heater must be checked to ensure the insulation resistance reading is above 2MΩ per element at 500 volts dc.

If the heater fails this test the power and control circuits must be isolated.

To install the heater carefully remove from the packaging and check for damage. The convector heater should be fixed into place using the pre-drilled holes and all terminal connections checked for tightness prior to energising.

The appliance must be securely fitted to a wall or floor using only the brackets provided and the orientation of the heaters must be strictly adhered to with the feet facing down at all times.

EXHEAT FCR Hazardous Area Convector Heaters – Applications

Applications for these electric heaters include:

EXHEAT

EXHEAT Stockist – Worldwide Delivery, Competitive Quotations

  • Spray booths
  • Aircraft hangers
  • Fuel servicing areas
  • Chemical plants
  • Offshore installations
  • Battery stores
  • Gas installations
  • Container heating
  • Storage areas
  • Frost protection

EXHEAT FCR Hazardous Area Convector Heaters Product Range

Suitable for Zone 1 & Zone 2 (IIA, IIB, IIC) gas groups.

Convector Heater ModelT ClassHazardous AreaWatts RatingVoltageWeight (Kg)
EXHEAT FCR 1T2-T4Zone 1 & Zone 21.024017
EXHEAT FCR 1/110T2-T4Zone 1 & Zone 21.011017
EXHEAT FCR 2T2-T4Zone 1 & Zone 22.024032
EXHEAT FCR 2/110T2-T4Zone 1 & Zone 22.011032
EXHEAT FCR 3T2-T4Zone 1 & Zone 23.024047
EXHEAT FCR 3/145T2-T4Zone 1 & Zone 23.0415/347

EXHEAT FCR Hazardous Area Air Warmers Product Range

These air warmers are suitable for Zone 1 & Zone 2 (IIA, IIB, IIC) gas groups according to ATEX | IECEx Directive.

EXHEAT FCR Hazardous Area Convector Heaters - Dimensions

EXHEAT FCR Hazardous Area Convector Heaters – Dimensions

EXHEAT FCR Hazardous Area Convector Heaters

EXHEAT Part NumberLoad (kW)Voltage (V)Weight (kg)Dim A (mm)
Convector Heaters Ex e II T3
FCR 11101110171240
FCR 110A1110191295
FCR 12401240/415171240
FCR 1240A1240191295
FCR 21102110321240
FCR 2110A2110341295
FCR 22402240/415321240
FCR 2240A2240341295
FCR 32403240/415471750
FCR 3240A3240491805

Air Heaters | Immersion Heaters | Line Heaters | Thermostats | ATEX & IECEX Certified Electrical Heaters

T&D – Experts in Equipment for Explosive AtmospheresExplosive Atmospheres EX

Trust Thorne & Derrick to specify and supply from stock safe and reliable Heat, Light & Power Products for use in hazardous area locations and explosive atmospheres certified to international standards including ATEX and IECEx – this includes Zone 1 / Zone 2 (Flammable Gas) or Zone 21 / Zone 22 (Dusts) and Class I, Division 1 and Division 2 hazardous area requirements.

Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.

Lighting | Sockets | Glands | Control Stations | Isolators | Push Buttons | Hazardous Area Equipment UK & Export Sales