Chromalox HSRM 5 | 5W/FT 120V 240V Trace Heating Cables

HSRM5-1CT

Trace Heating Cables

Chromalox HSRM 5 hazardous area trace heating cables are self regulating, medium temperature and provide process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 150º Celsius – with CSA and FM certification Chromalox HSRM heat trace cables ensures operating integrity in Div. 1 hazardous areas.

  • Manufacturer: Chromalox
  • Heating Cable Range: HSRM
  • Heating Cable Code: HSRM 5
  • Maximum Maintain Temperature : 150° Celsius
  • Maximum Continuous Exposure Temperature : Power Off 215° Celsius
  • Cable Type: Self Regulating Trace Heating Cables
  • Cable Ratings: 5 Watts Per Foot @ 50°F
  • Maximum Heating Cable Circuit Length: Up to 375 feet (Chromalox HSRM 5-1CT)
  • Maximum Heating Cable Circuit Length: Up to 750 feet (Chromalox HSRM 5-2CT)
  • Minimum Cable Bend Radius : 1-1/8″
  • See Also: Trace Heating
Chromalox HSRM Trace Heating Cable

Chromalox HSRM Trace Heating Cable

  1.  Twin 16 AWG Copper Buss Wires are able to provide reliable electrical current capability.
  2.  Semiconductive Polymer Core Matrix is the ‘self regulating component of the cable and it’s electrical resistance varies with temperature.
  3.  Polyolefin Jacket is flame retardant and electrically insulates the matrix and buss wires and provides resistance to water and some inorganic chemical solutions.
  4.  Tinned Copper Braid that provides additional mechanical protection in any environment, and a positive ground path.
  5.  High Temperature Fluoropolymer Overjacket  is a corrosion resistant, flame retardant overjacket is highly effective in many environments.

Cable Ordering Information

Chromalox HSRM 5

Output (W/Ft.)VoltageCable ModelChromalox Order CodeWt. /1000′ (Lbs.)
5 @ 50°F120VHSRM 5-1CT38217680
208V – 277VHSRM 5-2CT382168

Hazardous Area Approvals

FM Approved
• Class I, Division 1, Groups B, C, D
• Class II, Division 1, Groups E, F, G
• Class III, Division 1
• 5 and 8 Watt rated T3C Temperature Class
• 10 Watt rated T3A Temperature Class
• 15 and 20 Watt rated T2C Temperature Class

CSA Approved
• Class I, Division 1, Groups B, C, D
• Class II, Division 1, Groups E, F, G
• 5 and 8 Watt rated T3C Temperature Class
• 10 Watt rated T3A Temperature Class
• 15 and 20 Watt rated T2C Temperature Class

➡ See also : Electrical Heating for Hazardous Areas

Chromalox SLL Series Long Line Trace Heating Cable - Freeze Protection Of Pipes, Valves & Tanks

Trace Heating Cables & Systems – Design & Supply From Stock