Chromalox HSRM Hazardous Area Trace Heating Cable to 302°F (150°C) – Self Regulating

View Sub Products

Chromalox HSRM Hazardous Area Trace Heating Cable to 302°F (150°C)

Trace Heating Cables & Systems – Design & Supply From Stock

Chromalox HSRM Heat Trace Cables – Hazardous Area Trace Heating

Trace Heating

Chromalox HSRM hazardous area trace heating cables are self regulating and provide process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 150º Celsius – with CSA and FM certification Chromalox HSRM heat trace cables ensures operating integrity in Div. 1 hazardous environments.

Chromalox HSRM Hazardous Area Trace Heating Cable – Features

  • Energy efficient HSRM self regulating cables requires less energy as less heat is required
  • Simple to install cable and can be cut to any length (see max circuit length)
  • HSRM trace heating cables offer low installation costs and require less maintenance minimising downtime
  • Can be single overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps
  • Chromalox HL Connection Kits reduce installation time

Chromalox HsrM Hazardous area trace heating CABLE – SPECIFICATION

Chromalox HSRM heat trace cable wattages per metre at 10°C – 5, 8, 10, 15 and 20 watts.

  • Approximate Cable Size : 3/8″ W x 1/8″ H
  • Maximum Maintain Temperature : 150° Celsius
  • Maximum Continuous Exposure Temperature : Power Off 215° Celsius
  • Available Models (Voltages) : 120 and 208-277V
  • Minimum Cable Bend Radius : 1-1/8″
  • Trace Heating Cable Circuit Lengths : Up to 750 feet

Chromalox HSRM hazardous area trace heating cables are self-regulating as they increase power output as temperatures falls to provide guaranteed frost protection and temperature maintenance of industrial process and water pipework.

CHROMALOX HSRM Hazardous Area TRACE HEATING CABLE

Product Offering

Part Number Trace Heating Cable Description
382176Chromalox HSRM5-1CT 5W/FT 120V
382168Chromalox HSRM 5-2CT 5W/FT 240V
382150Chromalox HSRM8-1CT 8W/FT 120V
382141Chromalox HSRM8-2CT 8W/FT 240V
382133Chromalox HSRM10-1CT 10W/FT 120V
382125Chromalox HSRM10-2CT 10W/FT 240V
382117Chromalox HSRM15-1CT 15W/FT 120V
382109Chromalox HSRM15-2CT 15W/FT 240V
382096Chromalox HSRM20-1CT 20W/FT 120V
382088Chromalox HSRM20-2CT 20W/FT 240V

Chromalox HSRM Thermal Output Ratings on Insulated Metal Pipe

Chromalox HSRM Thermal Output Ratings on Insulated Metal Pipe

 

Chromalox HSRM Output Wattage at Alternate Voltages (W/Ft.)

Chromalox Part Number208V% Change In Output220V% Change In Output277V% Change In Output
Chromalox HSRM 53.85-234.25-156.45+23
Chromalox HSRM 86.4-206.88-1410.24+22
Chromalox HSRM 108.3-178.80-1212.50+20
Chromalox HSRM 1512.75-1513.50-1018.45+19
Chromalox HSRM 2017.6-1218.40-824.40+19

Chromalox HSRm SELF-REGULATING TRACE HEATING CABLE

Cable Construction

Chromalox HSRL Hazardous Area Trace Heating Cable - Construction

 

  • A Twin 16 AWG Copper Buss Wires are able to Provide reliable electrical current capability.
  • B Semiconductive Polymer Core Matrix is the ‘self regulating component of the cable and it’s electrical resistance varies with temperature.
  • C Polyolefin Jacket is flame retardant and electrically insulates the matric and buss wires and provides resistance to water and some inorganic chemical solutions.
  • D Tinned Copper Braid that provides additional mechanical protection in any environment, and a positive ground path.
  • E High Temperature Fluoropolymer Overjacket is a corrosion resistant, flame retardant overjacket is highly effective in many environments.

Chromalox HSRM HEAT TRACE CABLE – HAZARDOUS AREA CERTIFICATIONS

FM Approvals

  • Class I, Division 1, Groups B, C, D
  • Class II, Division 1, Groups E, F, G
  • Class III, Division 1
  • 5 and 8 Watt rated T3C Temperature Class
  • 10 Watt rated T3A Temperature Class
  • 15 and 20 Watt rated T2C Temperature Class

CSA 

  • Class I, Division 1, Groups B, C, D
  • Class II, Division 1, Groups E, F, G
  • 5 and 8 Watt rated T3C Temperature Class
  • 10 Watt rated T3A Temperature Class
  • 15 and 20 Watt rated T2C Temperature Class
Hazardous Area Heating Cables

Hazardous Area Heating Cables

Chromalox video with Chris Myers Product Manager at Chromalox explaining about their heat trace product offering including self regulating trace heating cable.

Trace Heating

Chromalox HSRM trace heating cables provide temperature maintenance and frost protection to pipework and mechanical services in all industries – typical applications include heating process pipework, instrument lines and storage tanks to maintain viscosity or prevent frost damage.

Heat Tracing Using Trace Heating Cables

Trace Heating Cables – providing process heating to pipework, vessel and bulk storage drums.

Chromalox

Chromalox technical manual covering trace heating cable selection, design, heat loss calculation, heat transfer fundamentals and radiant infrared heating theory.

Hazardous Area Gas Detection Metering Lighting Flow Measurement

➡ Did you know? T&D distribute Electrical, Mechanical, Process & Instrumentation Equipment for provide flow metering, gas detection, metering, lighting and power to hazardous areas.