Self Regulating Heat Tracing | Eltherm ELSR-SH+ ATEX Heat Tracing Cable (Up to 250 Degrees Celsius)
Thorne & Derrick | Distributed from Stock | UK & Export Sales | Customer Service Excellence | ATEX Compliant Solutions
SELF REGULATING Heat Tracing
ATEX Heat Tracing Cable | Eltherm ELSR-SH+
The Eltherm ELSR-SH+ high temperature self-regulating heat trace cables is designed for temperature maintenance in industrial processes – and is suitable for use up to 250 °C . The high chemical resistance allows the cables to be installed in environments with exposure to aggressive influences.
The self-regulating heat tracing cable provides frost protection and temperature maintenance to pipework, silos vessels ,tanks, valves and pumps. Suitable for use in the following industries:
- Chemistry and Petrochemistry
- Oil and Gas Industry
- Power plants
- Water and sanitation utilities
Our Team of Trained Sales Engineers are available to advise and support your heat trace cable enquiries – this includes design and supply of complex multi-kilometre, major-project systems to custom heat trace cable kits for the protection of winterisation against plant and factory facilities.
ELTHERM ELSR-SH+ TRACE HEATING CABLE – SPECIFICATION
Eltherm ELSR-SH+ Heater Cable wattages per metre at -60°C – 15, 30, 45, 60 and 90 watts.
- Nominal Supply Voltage :Â 230v
- Maximum Exposure Temperature : 250°C
- Minimum Installation Temperature : -60° Celsius
- Minimum Heater Cable Bend Radius :Â 25mm
- Heater Cable Outer Jacket:Â Fluoropolymer
- Bus Wire: Nickel plated copper, 1.23 mm²
- Bus wire – nickel plated copper, 1.23 mm²
- Self-regulating heating element
- InsulationÂ
- Protective braid – (Cu, tin plated)
- Outer jacket – fluoropolymer
Eltherm ELSR-SH+ self-regulating heater cables has a BOT cable design which has a high chemical resistance and is able to withstand aggressive chemicals, oil and fuel for improved service life due to the protective braid and fluoropolymer outer jacket.
ELTHERM ELSR-SH+ BENEFITS
- Temperature Classification T3*
- Seven Nominal outputs
- Moisture proof
- Resistant to chemicals
- Use in hazardous areas
*Except for 90 W/m: T2
The Eltherm ELSR-SH+ high temperature trace heating range is designed for temperature maintenance in industrial processes. The heat tracing cables high chemical resistance allows them to be installed in environments with exposure to aggressive influences.
TRACE HEATING CABLE SELECTION TABLE – ELTHERM ELSR-SH+
Contact T&D for technical guidance, heat loss calculations for pipework systems and optimum specification of the correct trace heater cable for your application.
Eltherm ELSR-SH+ Heater Cable | Nominal Output | Cable Dimensions Approx. (mm) | Cable Weight Approx. (g/m) |
ELSR-SH+-15-1-BOT | 16 W/m at 10ºC | 13.5 x 5.0 | 150 |
ELSR-SH+-30-1-BOT | 33 W/m at 10ºC | 13.5 x 5.0 | 150 |
ELSR-SH+-60-1-BOT | 66 W/m at 10ºC | 13.5 x 5.0 | 150 |
ELSR-SH+-15-2-BOT | 16 W/m at 10ºC | 13.5 x 5.0 | 150 |
ELSR-SH+-30-2-BOT | 33 W/m at 10ºC | 13.5 x 5.0 | 150 |
ELSR-SH+-60-2-BOT | 66 W/m at 10ºC | 13.5 x 5.0 | 150 |
ELSR-SH+-90-2-BOT | 98 W/m at 10ºC | 13.5 x 5.0 | 150 |
ELSR-SH+ HEATING CIRCUIT LENGTH
Switch on temperature [°C] | Nominal fuse rating [A] |
Heating circuit length*1 [m] |
 | ||||||
ELSR-SH+ -15-2-BOT |
ELSR-SH+ -30-2-BOT |
ELSR-SH+ -60-2-BOT |
ELSR-SH+ -90-2-BOT |
ELSR-SH+ -15-1-BOT |
ELSR-SH+ -30-1-BOT |
ELSR-SH+ -60-1-BOT |
 | ||
-30 | 16 | 135 | 75 | 45 | 18 | 65 | 40 | 20 | |
0 | 16 | 150 | 85 | 48 | 22 | ||||
10 | 16 | 150 | 90 | 50 | 25 |
*1Â Heating circuit lengths on the following conditions:
- 230 V nominal voltage
- Delayed action circuit breakers (C-characteristic) with 80 % max. load
- Maximum 10 % line voltage drop on heating cable bus wire
- Power connection to one heater end
Bespoke Heated Hose Designs | 40+ Years Experience from Process Heating Specialists | CONTACT US