Chromalox CWM 4-1C 4W/FT 120V Trace Heating Cables

chromalox-cwm-constant-wattage-trace-heating-cable-to-392f-200-c

Trace Heating Cables

  • Manufacturer: Chromalox
  • Heating Cable Range: CWM
  • Heating Cable Code: CWM 4-1C 4W/FT 120V
  • Cable Type: Constant Wattage, Medium Temperature
  • Circuit Load: 0.033 Amps/Ft.
  • Cable Voltage: 120V
  • Output Wattage at 120V: 4 W/Ft.
  • Maximum Heating Cable Circuit Length:  600 Ft.
  • Length Between Nodes: 36″
  • Approximate Cable Size: 0.30″W x 0.25″H
  • Minimum Cable Bend Radius: 1-1/4″
  • Heating Cable Maximum Exposure Temperature: Power Off, 392°F  (200°C)
  • See Also: Trace Heating

CWM trace heating cables manufactured by Chromalox, including CWM 4-1C, provide frost protection to pipework and valves, tanks and associated mechanical services – suitable for hazardous area zones including Div 2. The heating cables is for use on metallic pipes only.

Heating Cable Applications

  • Process Pipework Maintenance
  • Frost Protection of Pipework
  • Fluid Flow, Transfer & Viscosity Maintenance

Cable Ordering Information

Output (W/Ft.) Nominal Voltage (Vac) Model Description Wt./1000′ (Lbs.) Chromalox Order Code
4 120 CWM 4-1C Standard tinned-copper metallic braid for additional  protection and ground path 96 392040
CWM 4-1CT Fluoropolymer corrosion resistant overjacket over braid for hostile or corrosive environments 110 392075

  1. Twin 12 AWG Copper Buss Wires – Provide reliable, consistent electrical current
  2. FEP Insulation Jacket – Electrically insulates buss wires
  3. Pairing Jacket – Secures two buss wires together and provides wrapping surface for Nichrome wire
  4. Nickel Chromium Wire – Cable heating component
  5. FEP Insulation – Rugged outer sheath protects heating cable, assures longer service life, and provides protection against environmental application hazards
  6. Tinned Copper Braid – Plated copper braid increases robust construction, provides ground path and provides additional protection in any location (suffix “C” in model number)
  7. FEP – Fluoropolymer overjacket, over the braid, provides protection from most aqueous and chemically corrosive solutions (suffix “T” in model number) – ideal for trace heating systems installed in hazardous areas with explosive atmospheres

Hazardous Area Approvals

UL Listed for ordinary areas.

CSA Certified for ordinary and:

  • Class I, Div. 2, Groups A, B, C, D
  • Class II, Div. 2, Groups F, G. Rated T3 Temperature Class (Exception: Cable surface temperature shall not exceed 190°C in Class II, Div. 2, Group F; 165°C in Class II, Div. 2, Group G)

➡ See also : Electrical Heating for Hazardous Areas

Chromalox SLL Series Long Line Trace Heating Cable - Freeze Protection Of Pipes, Valves & Tanks

Trace Heating Cables & Systems – Design & Supply From Stock

 

Data Sheets