Chromalox SRL 5-1C 5W/FT 120V Trace Heating Cables

Chromalox SRL Self Regulating Cable

Trace Heating Cables

  • Manufacturer: Chromalox
  • Heating Cable Range: SRL
  • Heating Cable Code: SRL 5-1C 5W/FT 120V
  • Heating Cable Maximum Temperature Maintenance: 150°F (65°C)
  • Cable Type: Self Regulating Trace Heating Cables
  • Cable Ratings: 5 Watts Per Foot @ 50°F
  • Cable Voltage: 120V
  • Maximum Heating Cable Circuit Length: 270 Foot
  • See Also: Trace Heating

SRL trace heating cables manufactured by Chromalox, including SRL 5-1C, provide frost protection to pipework and valves, tanks and associated mechanical services – suitable for hazardous area zones including ATEX Zone 1 (Gas).

Hazardous Area Approvals

ATEX Directive

ATEX CE 0359 IIG Ex e IIC T* Gb Ta -60ËšC to 195ËšC

Hazardous Area Heating Cables

Heating Cables

IECEx

ITS 07.0018X Ex e IIC T5 Gb Ta -60ËšC to 95ËšC

FM Factory Mutual Approved Heating Cables for ordinary areas

UL Listed CSA Certified for Ordinary Areas
UL Listed for Fire Protection System Piping

FM approved heating cables for hazardous (classified) areas when used with Chromalox cable accessories
• Class I, Div. 2, Groups B, C, D (gases, vapours)
• Class II, Div. 2, Groups F, G (combustible dust)
• Class III, Div. 2 (easily ignitable fibres and filings)
• 3 Watt rated T6 temperature class
• 5 and 8 Watt rated T5 temperature class
• 10 Watt rated T4A temperature class – more information T Class Ratings

CSA Certified for hazardous (classified) areas when used with Chromalox accessories
• Class I, Div. 2, Groups A, B, C, D;
• Class II, Div. 2, Groups F, G

Maximum Cable Circuit Length (Ft.) by Start-Up Temperature (°F) and Breaker Size (Amps)
Heating Cable Rating SRL5-1C Trace Heating 
50°F Start-Up (Ft.)
Circuit Breaker
10 A 125
15 A 185
20 A 250
25 A 270
30 A NR
40 A NR
0°F Start-Up (Ft.)
Circuit Breaker
10 A 90
15 A 135
20 A 180
25 A 225
30 A 270
40 A NR
-20°F Start-Up (Ft.)
Circuit Breaker
10 A 80
15 A 120
20 A 160
25 A 205
30 A 245
40 A 270

 

Heating Cable Applications

  • Process Pipework Maintenance
  • Frost Protection of Pipework
  • Fluid Flow, Transfer & Viscosity Maintenance

Cable Ordering Information

  • Chromalox SRL 5-1C (PCN 382694) Heat Trace Cable Standard Tinned Copper Metallic Earth Braid for Ground Path
  • Chromalox SRL 5-1CR (PCN 382758) Heat Trace Cable TRP Overjacket for Protection Against Inorganic Chemical Solutions
  • Chromalox SRL 5-1CT (PCN 383443) Heat Trace Cable TPR Overjacket Fluoropolymer Corrosion Resistant Hazardous Areas
Heating Cables

Heating Cables

Chromalox SLL Series Long Line Trace Heating Cable - Freeze Protection Of Pipes, Valves & Tanks

Trace Heating Cables & Systems – Design & Supply From Stock

 

Data Sheets