Zone 1 Fluorescent Hazardous Area Lighting ATEX Ex db – Petrel 7 Series
Zone 1 Fluorescent Hazardous Area Lighting ATEX – Ex db Linear Light Fittings
Zone 1 Fluorescent Hazardous Area Lighting
ATEX Classification – Ex d II 2 G IIB or IIC T* Protection IP 66
Petrel 7 Series are high output fluorescent lighting suitable for Zone 1 hazardous area lighting applications with a wide range of lamps to be fitted from 8W to 70W. Available in both standard and emergency formats the Zone 1 ATEX light fittings have a range of sizes 1-6ft with a light output up to 12,400 lumens (subject to lamp choice).
Zone 1 fluorescent light fittings are manufactured from impact resistant polycarbonate and high specification marine grade aluminium – the hazardous area Zone 1 fluorescent light fitting is supplied anodised and painted.
Fluorescent emergency models are fitted with integral batteries (minimum 3 hour duration) and charging units for ease of fitting and maintenance – Zone 2 fluorescent version also available.
➡ See Zone 2 Hazardous Area Lighting for fluorescent, LED, floodlight and bulkhead type light fittings for potentially explosive atmospheres with ATEX certification.
➡ View full range of hazardous area lighting.
Zone 1 Fluorescent Hazardous Area Lighting
Zone 1 Hazardous Area Lighting For Potentially Explosive Atmospheres In Both Onshore & Offshore Locations
ZONE 1 FLUORESCENT
Hazardous Area & atex Approved
- Certification and Hazardous Area Approval Certification Code: II 2 G Ex db IIB/IIC Gb T*Ex tb IIIC T* Db
- Certification Number: CML14ATEX 1028X IECEx CML140012X
- Certification Standard: EN 60079, IEC 600791
- Protection: IP 66
Zone 1 Fluorescent Lighting ATEX
Benefits & Options
- Easily compatible – 24V to 254V fluorescent light fittings available
- 50/60Hz compatible
- Can be used in Zone 1 high ambient temperatures (up to 55°C)
- Through wiring (loop in, loop out) installation option. Use /TW suffix on reference code
- Single lamp fluorescent versions: Petrel 7108/S1/240/50 (1x8W), 7118/S2/240/50 (1x18W), 7136/S4/240/50 (1x36W), 7158/S5/240/50 (1x 58W), 7170/S6/240/50 (1x70W)
- Twin lamp fluorescent versions: Petrel 7208/S1/240/50 (2x8W), 7218/S2/240/50 (2x18W), 7236/S4/240/50 (2x36W), 7258/S5/240/50 (2x58W), 7270/S6/240/50 (2x70W)
- Sizes: S1 1x8W, 2x8W (448mm, 1ft). S2 1x18W, 2x18W (752mm, 2ft). S4 1x36W, 2x36W (1362mm, 4ft). S5 1x58W, 2x58W (1662mm, 5ft). S6 1x70W, 2x70W (1926mm, 6ft)
- 230v 50/60Hz Check for alternative voltages
- -20°C to +55°C standard supply subject to lamp and ambient temperature combinations (ask for details)
- 8w (T5), 18w, 36w, 58w, 70w (T8) (Lamps not provided)
where S = single lamp fitting and T = twin light fitting.
hazardous area zone 1 Single & Twin Light Fittings
Petrel Zone 1 fluorescent lighting fittings are available as single or twin lamps in 8 watts, 18 watts, 36 watts and 58 watts, 70 watts – contact T&D to discuss your hazardous area lighting requirements, we can provide lighting design layouts from the very simple to the extremely complex.
Zone 1
T&D distribute an extensive range of Zone 1 Hazardous Area Equipment including plugs/sockets, junction boxes/enclosures, isolators and control panels with ATEX certification for both Zone 1 and Zone 2 potentially explosive atmospheres.
Zone 1 Fluorescent Luminaire Sizes – Petrel 7 Series |
ATEX Certified Lighting |
Standard Fluorescent Range | |
1 (Single) or 2 (Twin) x 8 Watts | Zone 1 Ex d |
1 (Single) or 2 (Twin) x 18 Watts | Zone 1 Ex d |
1 (Single) or 2 (Twin) x 36 Watts | Zone 1 Ex d |
1 (Single) or 2 (Twin) x 58 Watts | Zone 1 Ex d |
1 (Single) or 2 (Twin) x 70 Watts | Zone 1 Ex d |
Emergency Fluorescent Range | |
1 (Single) or 2 (Twin) x 8 Watts | Zone 1 Ex d |
1 (Single) or 2 (Twin) x 18 Watts | Zone 1 Ex d |
1 (Single) or 2 (Twin) x 36 Watts | Zone 1 Ex d |
1 (Single) or 2 (Twin) x 58 Watts | Zone 1 Ex d |
Zone 1 Fluorescent Luminaire ATEX – Petrel 7 Series
ZONE 1 FLUORESCENT Lighting ATEX
PETREL 7 SERIES Technical Data
Standard Fluorescent Range | Emergency Fluorescent Range | |
Supply Voltage | 230V 50/60Hz standard. Check for alternative voltages | 230V 50/60Hz standard. Check for alternative voltages, Suitable for central battery operation |
Operating Temperature | -20ºC to +55ºC standard supply subject to lamp ambient temperature requirements | |
Control Gear | Electronic ballast | Electronic ballast. One lamp lit in emergency mode. |
Lamp Options | 8W (T5), 18W, 36W, 58W, 70W (T8) (Lamps not provided) | 8W (T5), 18W, 36W, 58W (Lamps not provided) |
Cable Entries | 4 x M20 – 2 each end (3 plugged) as standard other threads available | |
Terminals | 3 wire and earth. Cable size 4mm² max. Through wiring option available on 18W to 70W sizes |
3 wire and earth. Cable size 4mm² max. Through wiring option available on 18W to 58W sizes |
Mounting Facility | 2 x M8 tapped holes vertical and horizontal at both ends Size 1 335mm, Size 2 632mm, Size 4 1,242mm, Size 5 1,542mm, Size 6 1,806mm | |
Access | Terminals accessed via threaded end cover as is the gear tray which slides out | |
Material | Corrosion resistant marine grade anodised Aluminium body and high impact polycarbonate tube | |
Weight |
Size 1 – 3.0kgs Size 2 – 5.0kgs Size 4 – 4.7kgs Size 5 – 8.0kgs Size 6 – 9.0kgs |
Zone 1 Fluorescent Luminaire ATEX – Ex db Linear Light Fittings – Petrel 7 Series – Dimensions
Size | A/mm | B/mm |
1 | 335 | 448 |
2 | 632 | 752 |
4 | 1,242 | 1,362 |
5 | 1,542 | 1,662 |
6 | 1,806 | 1,962 |
Ordering Information
Part Number | Order Ref | Fluorescent Light Description | Light Source | Power Consumption | Size (mm) |
1H60701199 | 7108/S1/HF | 8w Ex d Zone 1 Luminaire | Single Tube Fluorescent | 1 x 8 watt | 448 |
1H60702199 | 7118/S2/HF | 18w Ex d Zone 1 Luminaire | Single Tube Fluorescent | 1 x 18 watt | 752 |
1H60704199 | 7136/S4/HF | 36w Ex d Zone 1 Luminaire | Single Tube Fluorescent | 1 x 36 watt | 1,362 |
1H60705199 | 7158/S5/HF | 58w Ex d Zone 1 Luminaire | Single Tube Fluorescent | 1 x 58 watt | 1,662 |
1H60706199 | 7170/S6/HF | 70w Ex d Zone 1 Luminaire | Single Tube Fluorescent | 1 x 70 watt | 1,926 |
1H60701299 | 7208/S1/HF | 2x8w Ex d Zone 1 Luminaire | Twin Tube Fluorescent | 2 x 8 watt | 448 |
1H60702299 | 7218/S2/HF | 2x8w Ex d Zone 1 Luminaire | Twin Tube Fluorescent | 2 x 18 watt | 752 |
1H60704299 | 7236/S4/HF | 2x36w Ex d Zone 1 Luminaire | Twin Tube Fluorescent | 2 x 36 watt | 1,362 |
1H60705299 | 7258/S5/HF | 2x58w Ex d Zone 1 Luminaire | Twin Tube Fluorescent | 2 x 58 watt | 1,662 |
1H60706299 | 7270/S6/HF | 2x70w Ex d Zone 1 Luminaire | Twin Tube Fluorescent | 2 x 70 watt | 1,926 |
Note: Lumen output dependent on lamp specification
To order Emergency variant add “/EM” to part number.
8w version available in non maintained, add “NM”
Zone 1: Petrel Bulkhead, Fluorescent Fitting, Well Glass, Floodlights & LED Luminaires – all ATEX Certified for hazardous area Zone 1 lighting.
Electrical, Mechanical, Process & Instrumentation – Your Explosive Atmosphere Experts
T&D supply Hazardous Area Plugs for safe electrical power distribution in Zone 1 / Zone 2 (10A to 680A) – Marechal DXN socket plugs and inlets are ATEX certified.