Zone 1 Wellglass Hazardous Area Lighting ATEX Ex de – Petrel 610

Zone 1 Wellglass Hazardous Area Light Fitting ATEX Ex de - Petrel 610

Zone 1 Wellglass Hazardous Area Light Fitting ATEX Ex de – Petrel 610

Zone 1 Wellglass Hazardous Area Lighting 

ATEX Classification – Ex ed II 2GD IIC T3 – T4 Protection IP 66

Petrel 610 light fittings are heavy duty wellglasses suitable for Zone 1 hazardous area lighting applications and can be supplied for use as a wellglass or indicator beacon.

Zone 1 wellglass hazardous area light fittings are available with a wide variety of lamp options and high temperature options can be supplied on request. Rotating beacon and flashing xenon options are available for use as an indicator beacon.

➡ See Zone 2 Hazardous Area Lighting for fluorescent, LED, floodlight and bulkhead type light fittings for potentially explosive atmospheres with ATEX certification.

➡ View full range of hazardous area lighting.

Hazardous Area Zone 1 Lighting - Wellglass

Zone 1 Hazardous Area Lighting For Potentially Explosive Atmospheres In Both Onshore & Offshore Locations

ZONE 1 WellGlass

ATEX - Zone 1 Wellglass

ATEX – Zone 1 Wellglass

hazardous area & atex Approved

  • Certification and Hazardous Area Approval Certification Code: Ex ed II 2GD IIC T3 – T4
  • Certification Number: SIRA 00 ATEX 1048. IECEx SIR 09.0027
  • Certification Standard: EN 60079, EN 61241, IEC 60079, IEC 61241
  • Protection: IP 66

Zone 1 WellGlass Light Fitting ATEX

Benefits & Options

  • Highly robust marine grade construction wellglass fitting

    Zone 1 Hazardous Area Lighting - Wellglass

    Hazardous Area Zone 1 Lighting Stockists & Suppliers Shipping Worldwide

  • Integral terminal chamber for low installation costs
  • External earthing
  • Group IIC – wellglass suitable for nearly all Zone 1 gas environments as standard
  • High ambient temperature versions up to 70°C
  • Coloured body and glass options
  • Internal or external reflectors
  • Wire guard available
  • Range of lamp sources available suitable for Zone 1 wellglass
  • Range of fresnel colours / glass options
Zone 1

T&D distribute an extensive range of Zone 1 Hazardous Area Equipment including plugs/sockets, junction boxes/enclosures, isolators and control panels with ATEX certification for both Zone 1 and Zone 2 potentially explosive atmospheres.

Zone 1 Wellglass - Hazardous Area Light Fitting - Petrel 610

Zone 1 Wellglass – Hazardous Area Light Fitting – Petrel 610

ZONE 1 WellGlass

Light Fitting ATEX certified

PETREL 610 Technical Data

Supply Voltage Beacons 230V, Warning lights 24V, 110-120V Check for alternative voltages
Operating Temperature -20ºC to +70ºC (Lamp dependant)
Control Gear (When Fitted) Ballast, ignitor and capacitor can be fitted within the luminaire
Wellglass Lamp Options Zone 1 certified with elliptical lamps (lamps not provided)
50W, 70W, 110W SON-E and 70W SON-R
50W, 80W, 125W HPMV/MBF
25W SL or 20W PLCE
150W GLS with ES (E27) lamp holder. BC holder also available
Cable Entries 2 x M20 – ISO (1 plugged as standard). Other threads available
Terminals 4 (4mm) wire and earth with looping facility. Cable crimping required at installation when looping
Mounting Facility Back mounted fixing strap
Access Terminals accessed via terminal cover retained by cap screws. Lamp and gear accessed via removable glass dome
Material Corrosion resistant marine grade aluminium body and bezel. Toughened Borosilicate glass dome
Finish 2 Pack epoxy paint on primed surface. Standard colour – Aqua. Additional costs for non standard colours
Wellglass Accessories Internal or external reflector
Pivot bracket for directional control
Pendant mount
Wire guard
Weight 9kg to 12kg lamp dependant
Dimensions 249mm x 328mm
Features 70ºC ambient option available.
Group IIC hazardous area as standard
Heavy duty construction

 

Zone 1 Hazardous Area Well Glass Light Fitting ATEX Ex de - Petrel 610 - Dimensions

Zone 1 Hazardous Area Well Glass Light Fitting ATEX Ex de – Petrel 610 – Dimensions

Ordering Information
Part Number Description Light Source Powe Consumption
610C/70WSON-E/240/50 610C/70WSON-E/240/50 SON – Elliptical 70 Watt SON-E
610C/110WSON-E/240/50 610C/110WSON-E/240/50 SON – Elliptical 110 Watt SON-E
610C/105W/HAL/240/50 610C/105W/HAL/240/50 105W Halogen Elliptical 105W (Max)
610C/20W/PLCE/240/50 610C/20W/PLCE/240/50 PLCE 20W (Max)
610C/XEN/VOLTAGE/COLOUR 610C/XEN/VOLTAGE/COLOUR Xenon Flash Various

 

Zone 1 Wellglass - Hazardous Area Light Fitting ATEX Ex de - Petrel 610 - Blue Lens

Zone 1 Wellglass – Hazardous Area Light Fitting ATEX Ex de – Petrel 610 – Blue Lens

 

Hazardous Area Zone 1 Zone 2 - Wellglass

Zone 1: Petrel Bulkhead, Fluorescent Fitting, Wellglass, Floodlights & LED Luminaires – all ATEX Certified for hazardous area Zone 1 lighting.

Explosive Atmospheres

Electrical, Mechanical, Process & Instrumentation – Your Explosive Atmosphere Experts

Hazardous Area Plugs

T&D supply Hazardous Area Plugs for safe electrical power distribution in Zone 1 / Zone 2 (10A to 680A) – Marechal DXN socket plugs and inlets are ATEX certified.

Data Sheets