3.3kV High Voltage Enclosure – HV High Voltage Junction Box Zone 1 & Zone 2 Hazardous Area ATEX

HV Enclosures & Junctions Up to 3.3kV
Abtech LR box high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution for 3.3kV systems up to 240sqmm cables – ATEX certified for Zone 1 and Zone 2 connection of HV cables in hazardous area locations.
3.3kV high voltage enclosure is suitable for extreme low temperature applications and can be configured to suit installation orientation on site.
Abtech LR box high voltage (HV) cable junction boxes are manufactured from 316L stainless steel and used primarily for jointing cables or as a connection box, the LR is supplied complete with three glands plates and the unique design can be modified by the installer to allow either left hand or right hand cable connections.
HIGH VOLTAGE HV JUNCTION BOX
ZONE 1 & ZONE 2 HAZARDOUS AREA
ATEX CERTIFIED
ABTECH LR Box

HV Junction Boxes Manufactured From 316 Stainless Steel For Offshore 3.3kV High Voltage Cable Connections & Terminations

Abtech LR Box General Arrangement HV Enclosure Drawing – cable termination, enclosure and junction box suitable for jointing, connecting and terminating HV cables 3.3kV.
Abtech Part Ref | Width (mm) Dimension X | Height (mm) Dimension Y | Depth (mm) Dimension Z | Maximum Voltage (kV) | Maximum Current (A) | Maximum Conductor Size (mm²) | Phase | Weight (kg) | Hazardous Area Enclosure |
LR52 LH | 510 | 510 | 220 | 3.3 | 1250 | 240 | 1 | 30 | Zone 1 & Zone 2 |
LR52 RH | 510 | 510 | 220 | 3.3 | 1250 | 240 | 1 | 30 | Zone 1 & Zone 2 |
LR73 LH | 650 | 950 | 220 | 3.3 | 1250 | 240 | 3 | 50 | Zone 1 & Zone 2 |
LR73 RH | 650 | 950 | 220 | 3.3 | 1250 | 240 | 3 | 50 | Zone 1 & Zone 2 |
HAZARDOUS AREA CERTIFICATION

High Voltage Enclosures & Junction Boxes (HV) – Hazardous Area
- ATEX EEx e (Zone 1 & Zone 2)
- NEMA 4X (CSA, UL & FM) Class 1 Division 2
- Deluge Tested To DTS-01
Zone 1 & 21, Gas and Dust / Class 1 Division 2
Type Of Explosion Protection – Ex e, Ex tb
Apparatus Hazardous Area Coding – Ex e IIC T4, Ex tb IIIC IP66 T650 C Db / Ex e IIC T3, Ex tb IIIC IP66 T80ºC Db
TEMPERATURE RATING
- Standard: -50° to +40°C (-58° to 104°F)
- Option: -50° to +55°C (-58° to 131°F)
HIGH VOLTAGE HV ENCLOSURE SPECIFICATION
- Electrical Enclosure Type – High Voltage (HV)
- Ingress Protection – IP66/67 to EN60529, Type 4X, DTS-01
- Material – 316L Stainless Steel (EN 1.4404) enclosure, silicone gasket and A4 stainless steel fixings
- Ambient Temperature Rating – 50°C to +40°C or -50°C to +55°C
- Maximum Number Of Busbars – 3
- Number Of HV Cable Gland Plates – 3
- Suitable for 3.3kV
- Crimp Lugs – 16mm² to 240mm²
- Earthing – Via Studs On Electrical Enclosure, Door & Cable Gland Plates
- Mounting – Via 3mm Thick External Mounting Straps, Slotted Upper Strap for Ease Of Installation
ENCLOSURE OPTIONS
- Abtech LR EP HV Junction Box Enclosure – Electro-polished
MV HV ELECTRICAL ENCLOSURES & JUNCTION BOXES
3.3KV 6.6KV 11KV 33KV HIGH VOLTAGES
T&D produce customised HV Junction Boxes & Electrical Enclosures suitable for safe installation and distribution of MV-HV electrical power in hazardous area locations – enclosures and junction boxes can be specified and supplied for 3.3kV, 6.6kV, 11kV and 33kV high voltage power networks where Ex-certified HV electrical equipment is required in accordance with ATEX and IECEx hazardous area certification.

HV High Voltage Specialists – Zone 1 & Zone 2 Hazardous Area Certified By ATEX
➡ View complete range: HV Junction Boxes & Electrical Enclosures

MV-HV Junction Boxes & Electrical Enclosures For 3.3kV, 11kV and 33kV Medium-High Voltage Networks – Industrial & Hazardous Area