Flameproof Ex d Control Stations Cast Iron – Pepperl Fuchs ASM

Hazardous Area Control Units & Stations – Pepperl Fuchs ASM
Flameproof Enclosures & Control Stations
Zones 1 & Zone 2 (21/22) Hazardous Areas
Pepperl Fuchs ASM control stations with Ex d Increased Safety explosion protection are comprised of three flameproof enclosures manufactured from cast iron and suitable for use in hazardous area locations, including Zone 1/Zone 2 (gas) and Zone 21/Zone 22 (dust).
Pepperl Fuchs ASM Ex d control stations are designed to meet the users exact specifications. Typical applications include terminal junction boxes, control junction boxes and engineered solutions.
Many safe area components of the ASM control stations can be installed inside the enclosures.
Increased Safety Ex d Control stations Cast iron
Pepperl Fuchs ASM
Features
- Cast iron enclosure
- Certified to Ex de and Ex tb explosion protection
- 3 enclosure size options
- Customizable configuration as per specification
- Control stations suitable for installation in Zone 1, Zone 2, Zone 21 and Zone 22
- Degree of protection IP66
- Thermo-resistant tempered glass window
INCREASED SAFETY EX D CONTROL stationS cast iron
PEPPERL FUCHS ASM
TechnIcal Data
Control Station Material | |
Body and cover | Cast iron |
Screws | Stainless steel |
Threads | Metric threaded |
Inhibiting treatments | Zinc rich epoxy powder primer plus epoxy powder top coat black |
Control Station Certification Characteristics | |
Marking to 94/9/EC | II 2GD |
Hazardous Area Zones | 1 – 21 – 2 – 22. |
Features | |
Enclosure cover | Hinged non-detachable |
Mounting | 2 x fabricated stainless steel mounting straps |

Flameproof Ex d Control Stations Cast Iron – Pepperl Fuchs ASM – Dimensions
Pepperl Fuchs ASM Part Number | Dimensions external (mm) | Dimensions internal (mm) | Fixation (mm) | Enclosure material | Weight | Drawing reference | ||||||
A | B | C | D | E | F | G | H | Diam. J | (kg) | |||
ASM130/CI | 210 | 185 | 156 | 150 | 125 | 85 | 240 | 120 | 9.1 | cast iron | 20 | B |
ASM150/CI | 335 | 310 | 205 | 275 | 250 | 133 | 360 | 240 | 10.3 | cast iron | 50 | C |
ASM170/CI | 560 | 560 | 266 | 460 | 460 | 174 | 650 | 400 | 10.3 | cast iron | 172 | D |
INCREASED SAFETY EX D CONTROL UNITS
hazardous area ATEX Certification

ATEX Control Units
II 2GD
Ex D Increased Safety Control units
A flameproof Ex d control unit is explosion protected by an enclosure which prevents the ignition of potentially explosive gases in hazardous area Zones 1 and Zone 2. The explosion protection concept of Ex d is to prevent the propagation of an internal explosion to the surrounding explosive atmosphere, and protecting the internal components from the environment, humidity, dirt, dust or water.

Explosion Proof Electrical Equipment – Motor Starters, Junction Boxes, Control Stations, Distribution Panels, Plugs & Sockets