Zone 2 (21/22) Hazardous Area LED Luminaire Lighting ATEX – Appleton LLEDA Viamaster
Zone 2 (21/22) Hazardous Area LED Luminaire Lighting ATEX – Appleton LLEDA Viamaster
Appleton LLEDA Viamaster is part of the Zone 2 (21/22) hazardous area LED luminaire ATEX lighting range that are specifically designed for simple installation and maintenance.
The Appleton LLEDA Viamaster can be manufactured for a new construction or retrofitted offering a more accurate and effective option for fluorescent fixtures.
Available in numerous options the LLEDA Viamaster range offers different voltages, lumen outputs and mounting styles suitable for almost any hazardous and industrial environments – providing hazardous area lighting with savings on installation, maintenance and energy costs due to the compact and efficient design.
The ATEX certified LED luminaires are suitable for use indoor or outdoors where protection against dirt, water and moisture is essential. Typical applications include oil refineries, petrochemical facilities, pulp and paper mills, food processing plants, oil refineries, warehouses, underground tunnels and general manufacturing facilities.
Appleton LLEDA Viamaster is also suitable for areas where there is a high degree of corrosion resistance required and where flammable gases, vapors and dusts are present.
Zone 2 (21/22) Hazardous Area LED Luminaire Lighting ATEX
Features & Benefits
- 60,000+ hour LED life for years of maintenance free hazardous area lighting
- Lightweight design, hinged cover with captive screws, and terminal block wiring for easy installation and maintenance
- Contemporary, low profile lighting design suitable for tight spaces
- Field replaceable components are available
- Industry-leading thermal management for safe, reliable operation over wide temperature range
- Optional safety cables prevent luminaire from falling
- Terminal blocks provided for field wiring
- ATEX/IECEx version:
- Full range of lumen outputs, with light distribution equivalent to Appleton’s FN Series
- Easy to retrofit the luminaire in same mounting footprint as Appleton’s FN Series fluorescent fixtures
- (1) M20 plug or (1) M25 plug provided
Appleton LLEDA Viamaster for use in hazardous locations defined by ATEX/IECEx
Appleton LLEDA Viamaster
Technical Data
Lamp | Ambient Temperature°C (°F) | Supply Wire Temperature°C (°F) | NEC/CEC Hazardous Area Classification | Gas/Dust Simultaneous *Class I, Division 2/Class II, Division 1 | ATEX/IECEx | ||||||
Gas | Dust | Gas | Dust | ||||||||
Lumen Output | Type | Class I, Division 2* |
Groups | Class I, Zone AEx nA IIC, Ex nA IIC |
Class II, Division 1 and 2 ** |
Groups | Ex nA IIC* | Ex tb IIIC Ex tc IIIC*** |
|||
2,400 | LED | 40 (104) | 60 (140) | T5 | A, B, C, D | T6 | — | — | — | T6 (69 °C) | 63 °C |
55 (131) | 65 (149) | T4A | A, B, C, D | T6 | — | — | — | T5 (89 °C) | 78 °C | ||
65 (149) | 75 (167) | T4A | A, B, C, D | T6 | — | — | — | T5 (94 °C) | 83 °C | ||
4,725 | LED | 40 (104) | 65 (149) | T4A | A, B, C, D | T6 | — | — | — | T4 (129 °C) | 64 °C |
55 (131) | 65 (149) | T4 | A, B, C, D | T6 | — | — | — | T3 (144 °C) | 79 °C | ||
65 (149) | 75 (167) | T4 | A, B, C, D | T6 | — | — | — | T3 (148 °C) | 84 °C | ||
7,800 | LED | 40 (104) | 65 (149) | T4A | A, B, C, D | T6 | — | — | — | T4 (130 °C) | 64 °C |
55 (131) | 65 (149) | T4A | A, B, C, D | T6 | — | — | — | T3 (145 °C) | 79 °C | ||
65 (149) | 75 (167) | T4 | A, B, C, D | T6 | — | — | — | T3 (149 °C) | 84 °C |
* T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC.
**T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and 2 as designated by the NEC or Zone 2 (Gas) and 22
(Dust) locations as designated by the IEC.
***T numbers represent the maximum external surface temperature for use in Zones 21 and 22.
Appleton LLEDA Viamaster Range
Appleton Part Reference | LLEDAA2L2BUZ2 | LLEDAA2L5BUZ2 | LLEDAA2L7BUZ2 | |
Voltage Range | BU | 120 – 277 Vac, 50/60 Hz | 120 – 277 Vac, 50/60 Hz | 120 – 277 Vac, 50/60 Hz |
LED Lumens | 2,200 | 4,400 | 7,800 | |
Input Power (W) | 22 | 45 | 81 | |
Efficacy (LPW) | 104 | 103 | 95 | |
Ambient Temperature | -40 °C up to +65 °C (-40 °F up to +149 °F) |
-40 °C up to +60 °C (-40°F up to +140 °F) |
-40 °C up to +60 °C (-40 °F up to +140 °F) |
|
T-Rating | T5 @ +65 °C (+149 °F) | T3 @ +60 °C (+140 °F) | T3 @ +60 °C (+140 °F) | |
Correlated Color Temperature (CCT) | 5650 | 5650 | 5650 | |
Color Rendering Index (CRI) | 70 | 70 | 70 | |
Fixture Length | 0.6 m (2 ft) | 0.6 m (2 ft) | 1.2 m (4 ft) | |
Fixture Weight | 6.1 kg (13.7 lbs) | 6.4 kg (14 lbs) | 9 kg (19.15 lbs) | |
Standard Materials | Housing: copperfree aluminum Finish: gray polyesterLens: thermal shock- and impact-resistant polycarbonate lens |
|||
Lifetime | 60,000+ hours |
Appleton LLEDA Viamaster
ATEX/IECEx Certifications for hazardous areas
ATEX LED Luminaires
- Zone 2 and 22
–II 3 GD
– EPL Gc and Dc
– Ex nA IIC; Ex tc IIIC
– IP66/KO08 - Zone 21
–II 2 D
– EPL Db
– Ex tb IIIC
– KO08
NEC/CEC
Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx nA IIC Ex nA IIC Simultaneous Exposure (Class I, Division 2/Class II, Division 1)
NEC/CEC
Type 3R, 4X Wet Locations IP66
ATEX/IECEx
Zones 2 and Zones 22 II 3 GD EPL Gc and Dc Ex nA IIC; Ex tc IIIC IP66; IK08
ATEX/IECEx
Zone 21 II 2 D EPL Db Ex tb IIIC IK08
Appleton LLEDA Viamaster
T&D, The Hazardous Area Experts | ATEX Plugs Sockets | ATEX Isolators | ATEX Heaters | ATEX Enclosures