Flameproof Junction Box Ex d – Zone 1 & Zone 2 Hazardous Area Junction Boxes

Flameproof Junction Box Ex d

Flameproof Junction Box Ex d – Stainless Steel Zone 1 & Zone 2 Hazardous Area

Flameproof Junction Box Ex d

Abtech SSD flameproof junction boxes (Ex d) are ATEX certified and suitable for Zone 1 and Zone 2 hazardous areas. The Ex d flameproof junction box is designed to house electrical and electronic apparatus within Zone 1 and Zone 21 hazardous areas.

Abtech SSD stainless steel junction boxes have an Ex d flameproof design allowing potentially sparking equipment to be safely installed in areas where explosive gases or dust may be present. The use of 316L marine grade stainless steel ensures maximum environmental protection for harsh onshore and offshore operating conditions.

Flameproof Ex d Junction Boxes

Zone 1 & Zone 2 Hazardous Area

Abtech SSD Features

Zone 1 Zone 2 Hazardous Area Junction Box Enclosures

Junction Boxes & Enclosures

  • Ambient temperature range of – 20°C to + 40°C
  • Zone 1 & Zone 2 Hazardous Area Certified By ATEX
  • Flameproof Enclosure
  • IP66 to EN60529 rating
  • Up to 24kV ac or 1500V dc voltage rating

Zone 1 Hazardous Area

A hazardous area location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.

Zone 2 Hazardous Area

A hazardous area location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, persists for a short  period only.

ATEX Explained

The ATEX Directive consists of two EU directives describing the type of equipment and hazardous area location within a potentially explosive atmosphere. ATEX originates its name from the French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles.

Cable entries can be drilled in the enclosure or junction box door, sides or via the cable gland plates – cable entries can also be drilled through the rear face of the stainless steel enclosure (EEx’e’ hazardous area versions).

The hazardous area enclosures include a hinged, lift-off door secured to the junction box using 4 captive stainless steel screws which also maintain the correct compression on the gasket.

Abtech SSD Enclosures – Product Specification

Abtech Product Type  Flameproof Ex d Enclosure Range
Ingress Protection IP66 to EN60529
Material 316 Stainless Steel enclosure, cover & hinges complete with 316 Stainless Steel fasteners
Mounting Plate 316 Stainless Steel
Components Switches, Breakers, RCD units, Indicator lamps, motor controllers, etc
Voltage Rating Up to 24kV ac or 1500V dc
Cable Entry Variable Metric or NPT entry combinations on any of the 4 sides
Mounting Via rear mounting lugs

Abtech SSD

Abtech SSD Model External
Dimensions (mm)
Internal
Dimensions (mm)
Fixing Dimensions (mm) Mounting Plate (mm) Weight
(kg)
A B C D E F X V Z G H
SSD113 150 180 106 100 130 80 140 130 7 90 120 11
SSD234 230 290 178 170 230 150 225 225 9 150 210 23
SSD434-A 230 400 180 170 340 150 225 335 9 150 320 30
SSD434-B 280 400 180 220 340 150 275 335 9 200 320 34
SSD435 270 460 220 210 400 190 265 395 9 190 380 42
SSD445-A 310 410 220 250 350 190 315 345 9 230 330 42
SSD445 370 450 224 310 390 190 365 385 9 290 370 61
SSD546 340 600 244 270 530 210 325 525 11 250 510 70
SSD556-A 440 500 250 370 430 210 425 425 11 350 410 83
SSD556-B 470 560 250 400 490 210 455 485 11 380 470 88
SSD646 330 710 290 250 630 250 305 625 11 230 610 104
SSD656 420 770 297 340 690 250 395 685 13 320 670 146
SSD667 530 780 305 450 700 250 510 675 15 430 680 207
SSD768 670 1120 450 570 1020 390 650/550 1000/1100 15 550 1000 436

 

Abtech SSD Stainless Steel - Dimensions

Abtech SSD Stainless Steel – Dimensions

Enclosure Options
MS Mild Steel
H2 Group IIB+ H2 version
RALxxxx Paint Finish (Any RAL colour)Note: Maximum paint thickness limited to 2mm for IIB and 0.2mm for IIB+H2 areas
INT Internal Flange
W Window options available for window fitted to cover or sides
BD Breather Drain (Stainless Steel M20 or 1/2″ NPT)
Abtech SSD Stainless Steel Electrical Enclosures & Junction Boxes - Zone 1 & Zone 2

Abtech SSD Stainless Steel Electrical Enclosures & Junction Boxes – Zone 1 & Zone 2

Hazardous Area Certification

Abtech SSD Stainless Steel

Abtech SSD Stainless Steel

Abtech SSD stainless steel enclosures are certified according to leading hazardous area classifications including:

  • Area Classification – Group IIB Category 2 GD (Zone 1/21 and 2/22), Option: Group IIB+ H2 Category 2 GD (Zone 1/21 and 2/22)
  • Type of Protection – Ex db (Flameproof), Ex tb (Dust), Ex db [ia/ib] (Intrinsically Safe)*
  • Apparatus Coding – Ex db IIB or IIB+H2 T* Gb, Ex tb* IIIC T* °C Db
    Ex db [ia Ga] IIB or IIB+H2 T6 Gb, Ex tb [ia Da] IIIC T85 °C Db
    Ex db [ib Gb] IIB or IIB+H2 T6 Gb, Ex tb [ib Db] IIIC T85 °C Db
  • Certificate Number – INERIS 13ATEX0019X / IECEx INE14.0061X

T&D, The Explosive Atmosphere Experts, provide a single-source capability for the most extensive range of Electrical, Mechanical, Process & Instrumentation Equipment suitable for hazardous area locations.

Hazardous Area Electrical Enclosures & Junction Boxes

Hazardous Area Electrical Enclosures & Junction Boxes

Hazardous Area Zone 1 Zone 2 Enclosure Junction Box

With international hazardous area classifications, including ATEX, Abtech SSD stainless steel junction boxes and enclosures are suitable for onshore and offshore installation in both Zone 1 & Zone 2 hazardous area locations. T&D provide pre-assembled terminal enclosures for use as hazardous area lighting, power, heat tracing and instrument junction boxes with increased safety, intrinsically safe and flameproof explosion protection methods – we can custom supply high voltage enclosures for 3.3kV, 6.6kV, 11kV and 33kV networks.

Data Sheets