Ex d Enclosures & Junction Boxes – Zone 1 & Zone 2 Aluminium Hazardous Area Enclosures

Ex d Enclosures & Junction Boxes – Aluminium Zone 1 & Zone 2 Hazardous Area Enclosures

Ex d Enclosures & Junction Boxes – Aluminium Zone 1 & Zone 2 Hazardous Area Enclosures

Abtech SSD aluminium electrical enclosures and junction boxes are ATEX certified and suitable for Zone 1 and Zone 2 hazardous areas. The Ex d enclosure designed to house electrical and electronic apparatus within Zone 1 and 21 hazardous areas.

Abtech SSD aluminium has a flameproof design that allows potentially sparking equipment to be safely installed in areas where explosive gases or dust may be present. The SSD-AL comes painted externally to RAL7001 grey providing significant levels of environmental protection.

Ex d Enclosures

Zone 1 & Zone 2 Hazardous Area

Abtech SSD Features

Zone 1 Zone 2 Hazardous Area Junction Box Enclosures

Junction Boxes & Enclosures

  • Ambient temperature range of – 20°C to + 40°C
  • Zone 1 & Zone 2 Hazardous Area Certified By ATEX
  • Flameproof Enclosure
  • IP66 to EN60529 rating
  • Up to 24kV ac or 1500V dc voltage rating

Zone 1

A hazardous area location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.

Zone 2

A hazardous area location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, persists for a short  period only.

ATEX Explained

The ATEX Directive consists of two EU directives describing the type of equipment and hazardous area location within a potentially explosive atmosphere. ATEX originates its name from the French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles.

Cable entries can be drilled in the enclosure or junction box door, sides or via the cable gland plates – cable entries can also be drilled through the rear face of the stainless steel enclosure (EEx’e’ hazardous area versions).

The hazardous area enclosures include a hinged, lift-off door secured to the junction box using 4 captive stainless steel screws which also maintain the correct compression on the gasket.

Abtech SSD Aluminium – Product Specification

Abtech Product Type  Flameproof Enclosure Range
Ingress Protection IP66 to EN60529
Material Aluminium enclosure, cover & hinges complete with 316 Stainless Steel fasteners
Mounting Plate Galvanized Steel
Components Switches, Breakers, RCD units, Indicator lamps, motor controllers, etc
Voltage Rating Up to 24kV ac or 1500V dc
Cable Entry Variable Metric or NPT entry combinations on any of the 4 sides
Mounting Via adjustable rear mounting feet

Abtech SSD

Abtech SSD Model EXTERNAL
Dimensions (mm)
INTERNAL
Dimensions (mm)
FIXING Dimensions (mm) Mounting Plate (mm) Weight
(kg)
A B C D E F X1/X2 Y1/Y2 Z G H
SSD-AL224 250 314 197 163 227 140 230/
120
180/
290
8 150 215 10
SSD-AL425 247 425 252 163 340 191 238/
128
290/
400
8 150 321 15
SSD-AL446 412 489 281 306 383 209 392/
255
335/
472
10 290 360 34
SSD-AL456 493 532 278 384 422 208 457/
320
360/
497
10 358 394 40
SSD-AL566 540 594 337 425 479 238 535/
360
400/
575
12 391 446 78
SSD-AL656 445 833 340 333 718 241 425/
250
630/
805
12 294 670 87
SSD-AL666 610 832 340 497 714 240 580/
405
630/
805
12 450 670 119
SSD-AL667 612 832 436 495 713 337 580/
405
630/
805
12 450 670 130

 

Abtech SSD Aluminium - Dimensions

Abtech SSD Aluminium – Dimensions

Enclosure Options
H2 Group IIB+ H2 version
RALxxxx Paint Finish (Any RAL colour)Note: Maximum paint thickness limited to 2mm for IIB and 0.2mm for IIB+H2 areas
W Window options available for window fitted to cover or sides
BD Breather Drain (Stainless Steel M20 or 1/2″ NPT)
Abtech SSD Aluminium Electrical Enclosures & Junction Boxes - Zone 1 & Zone 2

Abtech SSD Aluminium Electrical Enclosures & Junction Boxes – Zone 1 & Zone 2

Hazardous Area Certification

Abtech SSD Aluminium

Abtech SSD Aluminium

Abtech SSD aluminium enclosures are certified according to leading hazardous area classifications including:

  • Area Classification – Group IIB Category 2 GD (Zone 1/21 and 2/22), Option: Group IIB+ H2 Category 2 GD (Zone 1/21 and 2/22)
  • Type of Protection – Ex db (Flameproof), Ex tb (Dust), Ex db [ia/ib] (Intrinsically Safe)*
  • Apparatus Coding – Ex db IIB or IIB+H2 T* Gb, Ex tb* IIIC T* °C Db
    Ex db [ia Ga] IIB or IIB+H2 T6 Gb, Ex tb [ia Da] IIIC T85 °C Db
    Ex db [ib Gb] IIB or IIB+H2 T6 Gb, Ex tb [ib Db] IIIC T85 °C Db
  • Certificate Number – INERIS 13ATEX0019X / IECEx INE14.0061X

T&D, The Explosive Atmosphere Experts, provide a single-source capability for the most extensive range of Electrical, Mechanical, Process & Instrumentation Equipment suitable for hazardous area locations.

Hazardous Area Electrical Enclosures & Junction Boxes

Hazardous Area Electrical Enclosures & Junction Boxes

Hazardous Area Zone 1 Zone 2 Enclosure Junction Box

With international hazardous area classifications, including ATEX, Abtech SSD aluminium junction boxes and enclosures are suitable for onshore and offshore installation in both Zone 1 & Zone 2 hazardous area locations. T&D provide pre-assembled terminal enclosures for use as hazardous area lighting, power, heat tracing and instrument junction boxes with increased safety, intrinsically safe and flameproof explosion protection methods – we can custom supply high voltage enclosures for 3.3kV, 6.6kV, 11kV and 33kV networks.

Data Sheets