ATEX Loudspeakers Zone 1 & Zone 2 Weatherproof Ex d(e) – Eaton DB4B Hazardous Area Loudspeakers Up To 25 Watts

ATEX Loudspeakers Zone 1 & Zone 2 Weatherproof Ex d(e) – Eaton DB4B Hazardous Area Loudspeakers Up To 25 Watts
ATEX Loudspeakers Zone 1 & Zone 2
Eaton DB4B are ATEX loudspeakers with a high power explosion proof speaker, introduced as a replacement for the DB4 with improved intelligibility and acoustic performance.
Certified for use in a wide range of temperatures (from -55ºC to +70ºC) the Ex enclosure is manufactured from GRP with a rugged thermoplastic flare providing a corrosion free and aesthetically pleasing product suitable for use in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.
The frequency response of the hazardous area loudspeakers ensures that critical voice messages and general alarm tones are highly intelligible. The specific SPL figure for sensitivity is 1W @ 1m is 110dB whilst at 1m the 25W unit produces 124dB, the 15W unit 122dB and the 8W unit 119dB.
Options include DC blocking capacitors for monitored systems, resettable fuses for compliance with marine regulations and a swivel bracket that gives the installer greater flexibility when positioning the unit. The short flare option is a worthy addition to the range offering a high SPL and wide dispersion angle in a compact unit.

Eaton DB4B
ATEX Loudspeakers Zone 1 & Zone 2
ATEXFeatures
- Ex d / Ex de IIC / IIIC T4/T5/T6.
- ATEX certified.
- IECEx certified.
- cULus certified
- INMETRO certified
- TR CU certified
- SIL2 certified
- DNV certified
- CCOE certified
- Certified temperature -55ºC to +70ºC.*
- IP66 & IP67.
- Optional Ex e terminal chamber.
- 124dB at 25W, 1m.*
- 8W, 15W & 25W versions.
- Power tappings, via integral transformer.
- Frequency response 350Hz – 8kHz.
- Ex enclosure – Glass reinforced polyester.
- Flare – High impact thermoplastic polyester.
- Stainless steel mounting bracket and cover screws.
- Mounting bracket has ratchet facility as standard.
- Optional swivel bracket available

Eaton MEDC DB4B – Dimensions

DB4N IIc Long Flare, 25W, 1m SPL vs Frequency Swept Sine-Wave, Unsmoothed ±3db
Transformer: Used by combining the rated power tappings below:
Tappings | Power | ||
8W | 15W | 25W | |
1:2 | 8.0 | 15.0 | 25.0 |
2:3 | 4.0 | 7.5 | 12.5 |
3:4 | 2.0 | 5.0 | 6.0 |
1:3 | 1.5 | 4.0 | 4.0 |
2:4 | 0.7 | 2.0 | 2.0 |
1:4 | 0.4 | 0.8 | 1.0 |
Eaton MEDC DB4B
Sound pressure level at 1m (dB)
Values in dB @ 1m (Unsmoothed, peak values) |
8W | 15W | 25W | ||||
Long | Short | Long | Short | Long | Short | ||
IIC Gas | 1.0kHz | 115 | 112 | 117 | 114 | 120 | 117 |
IIC Gas | 1.4kHz | 119 | 116 | 122 | 119 | 124 | 122 |
IIC & IIIC Gas & Dust | 1.0kHz | 110 | 107 | 112 | 109 | 115 | 112 |
IIC & IIIC Gas & Dust | 1.4kHz | 114 | 111 | 117 | 114 | 119 | 116 |
MEDC SM87JB Hazardous Area Loudspeakers
Technical Specification
Hazardous Area Certification | |||||||||||||||||
ATEX Ex d Gas | Cert. no. Baseefa13ATEX0229X. Certified to: EN60079-0,1 Ex II 2G, Ex d IIC T4/T5/T6 Gb |
||||||||||||||||
ATEX Ex d Gas & Dust | Cert. no. Baseefa13ATEX0231X. Certified to: EN60079-0,1,31 Ex II 2GD, Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66 |
||||||||||||||||
ATEX Ex de Gas | Cert. no. Baseefa13ATEX0232X. Certified to: EN60079-0,1,7 Ex II 2G, Ex de IIC T4/T5/T6 Gb |
||||||||||||||||
ATEX Ex de Gas & Dust | Cert. no. Baseefa13ATEX0233X. Certified to: EN60079-0,1,7,31 Ex II 2GD, Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66 |
||||||||||||||||
IECEx Ex d G | Cert. no. IECEx BAS 13.0112X. Certified to: IEC60079-0,1 Ex d IIC T4/T5/T6 Gb |
||||||||||||||||
IECEx Ex d Gas & Dust | Cert. no. IECEx BAS 13.0113X. Certified to: IEC60079-0,1,31 Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66 |
||||||||||||||||
IECEx Ex de Gas | Cert. no. IECEx BAS 13.0114X. Certified to: IEC60079-0,1,7 Ex de IIC T4/T5/T6 Gb |
||||||||||||||||
IECEx Ex de Gas & Dust | Cert. no. IECEx BAS 13.0115X. Certified to: EN60079-0,1,7,31 Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66 |
||||||||||||||||
UL Haz Locs | UL certified for USA and Canada, listing no. E203310 Class I, Div 2. T4/T5/T6, Groups A-D. Class I, Zone 1, Ex d IIC / AEx d IIC Gb Class II, Div 1. T135°C/T100°C/T85°C, Groups E,F&G (Canada only*) Class II, Div 2. T135°C/T100°C/T85°C, Groups F&G. Zone 21 AEx tb IIIC Class III Div 1 *Contact T&D for ordering details |
||||||||||||||||
UL Ord Locs | UL certified for USA and Canada, listing no. S8847 | ||||||||||||||||
TR CU Ex d Gas | 1Ex d IIC T4/T5/T6 Gb | ||||||||||||||||
TR CU Ex d Gas & Dust | 1Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db | ||||||||||||||||
TR CU Ex de Gas | 1Ex de IIC T4/T5/T6 Gb | ||||||||||||||||
TR CU Ex de Gas & Dust | 1Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db | ||||||||||||||||
Russian Fire Approval | All TR CU certified units are Russian Fire Approved | ||||||||||||||||
CQST Ex d Gas | Ex d IIC T4/T5/T6 Gb | ||||||||||||||||
CQST Ex d Gas & Dust | Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db | ||||||||||||||||
INMETRO Ex d Gas | Ex d IIC T4/T5/T6 Gb | ||||||||||||||||
INMETRO Ex d Gas & Dust | Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66 | ||||||||||||||||
INMETRO Ex de Gas | Ex de IIC T4/T5/T6 Gb | ||||||||||||||||
INMETRO Ex de Gas & Dust | Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66 | ||||||||||||||||
SIL | SIL 2 certification to IEC61508. Cert number 20151119-4786827453 | ||||||||||||||||
Type approval | DNV (IEC60945) | ||||||||||||||||
Specifications | |||||||||||||||||
Material | Ex enclosure – flame retardant, UV stable, glass reinforced polyester Flare – flame retardant, high impact, UV stable, thermoplastic polyester (UV stability tested to ISO 4892 part 3) Hardware – bracket, fixings and captive cover screws in 316 stainless steel |
||||||||||||||||
Fire retardancy | Body – glass reinforced polyester. V0 flammability rating Outer flare – thermoplastic polyester. V0 flammability rating |
||||||||||||||||
Finish | Body – natural black. Flare – natural black, natural red or painted as specified (Black short flare painted black) |
||||||||||||||||
Rated power | 8W, 15W or 25W (other ratings available, contact T&D) | ||||||||||||||||
Frequency range | Frequency response 350Hz to 8kHz 8W and 15W units are available for use @ 200Hz |
||||||||||||||||
Weight | Ex d/UL – 5.0kg, Ex de – 5.8kg. Based on long flare with transformer | ||||||||||||||||
Ingress protection | IP66 & IP67, NEMA 4X & 6. (IPx7 & NEMA 6 on terminal chamber only) | ||||||||||||||||
Earth continuity | Optional for Ex de version. Not available on Ex d unit | ||||||||||||||||
Entries | Up to 2 x M20 or 1/2” NPT. Blanking plug available | ||||||||||||||||
Terminals | Ex d – 8 x 2.5sqmm (4sqmm solid conductor)/ 12AWG. Ex de – 8 x 4.0sqmm | ||||||||||||||||
Mounting arrangement | Stainless steel bracket with ratchet facility, optional swivel bracket available | ||||||||||||||||
Labels | Optional duty and tag labels available | ||||||||||||||||
Dispersion angle | Long flare (short in brackets), -6dB, 1kHz = 140º (240º), 4kHz = 40º (50º) | ||||||||||||||||
Driver impedance | 8Ω | ||||||||||||||||
SPL 1W/1m (sensitivity) | IIC long flare, 1kHz – 106dB, 1.4kHz – 110dB | ||||||||||||||||
Certified temperature |
|
EATON DB4B – ORDERING REQUIREMENTS
The following code is designed to help in selection of the correct Eaton hazardous area loudspeakers with ATEX approval and certification. Build up the part number by inserting the code for each component into the appropriate box.

Eaton DB4B – Ordering Requirements

ATEX Loudspeakers
Eaton MEDC
Eaton MEDC have developed ATEX products designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment. T&D distribute the extensive range of Eaton MEDC ATEX Certified manual call points, visual, audible alarms, loudspeakers and telephones for hazardous area workplaces, including Zone 1 & Zone 2 explosive atmospheres.
Thorne & Derrick, are the Explosive Atmosphere Experts, distributing an extensive range of ATEX Certified Equipment including heat tracing cables and systems, electrical heating products, electrical enclosures and plug/sockets outlets.
Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.
➡ Cable Cleats | Cable Lugs | Cable Transits | Cable Joints
Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical