ATEX Loudspeakers Zone 1 & Zone 2 Weatherproof Ex d(e) – Eaton DB4B Hazardous Area Loudspeakers Up To 25 Watts

ATEX Loudspeakers Zone 1 & Zone 2 Weatherproof Ex d(e) – Eaton DB4B Hazardous Area Loudspeakers Up To 25 Watts

ATEX Loudspeakers Zone 1 & Zone 2 Weatherproof Ex d(e) – Eaton DB4B Hazardous Area Loudspeakers Up To 25 Watts

ATEX Loudspeakers Zone 1 & Zone 2

Eaton DB4B are ATEX loudspeakers with a high power explosion proof speaker, introduced as a replacement for the DB4 with improved intelligibility and acoustic performance.

Certified for use in a wide range of temperatures (from -55ºC to +70ºC) the Ex enclosure is manufactured from GRP with a rugged thermoplastic flare providing a corrosion free and aesthetically pleasing product suitable for use in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

The frequency response of the hazardous area loudspeakers ensures that critical voice messages and general alarm tones are highly intelligible. The specific SPL figure for sensitivity is 1W @ 1m is 110dB whilst at 1m the 25W unit produces 124dB, the 15W unit 122dB and the 8W unit 119dB.

Options include DC blocking capacitors for monitored systems, resettable fuses for compliance with marine regulations and a swivel bracket that gives the installer greater flexibility when positioning the unit. The short flare option is a worthy addition to the range offering a high SPL and wide dispersion angle in a compact unit.

Eaton DB4B

Eaton DB4B

ATEX Loudspeakers Zone 1 & Zone 2

ATEX

Features

  • Ex d / Ex de IIC / IIIC T4/T5/T6.
  • ATEX certified.
  • IECEx certified.
  • cULus certified
  • INMETRO certified
  • TR CU certified
  • SIL2 certified
  • DNV certified
  • CCOE certified
  • Certified temperature -55ºC to +70ºC.*
  • IP66 & IP67.
  • Optional Ex e terminal chamber.
  • 124dB at 25W, 1m.*
  • 8W, 15W & 25W versions.
  • Power tappings, via integral transformer.
  • Frequency response 350Hz – 8kHz.
  • Ex enclosure – Glass reinforced polyester.
  • Flare – High impact thermoplastic polyester.
  • Stainless steel mounting bracket and cover screws.
  • Mounting bracket has ratchet facility as standard.
  • Optional swivel bracket available
Eaton MEDC DB4B - Dimensions

Eaton MEDC DB4B – Dimensions

DB4N IIc Long Flare, 25W, 1m SPL vs Frequency Swept Sine-Wave, Unsmoothed ±3db

DB4N IIc Long Flare, 25W, 1m SPL vs Frequency Swept Sine-Wave, Unsmoothed ±3db

Transformer: Used by combining the rated power tappings below:

Tappings Power
8W 15W 25W
1:2 8.0 15.0 25.0
2:3 4.0 7.5 12.5
3:4 2.0 5.0 6.0
1:3 1.5 4.0 4.0
2:4 0.7 2.0 2.0
1:4 0.4 0.8 1.0

Eaton MEDC DB4B

Sound pressure level at 1m (dB)

Values in dB @ 1m
(Unsmoothed, peak values)
8W 15W 25W
Long Short Long Short Long Short
IIC Gas 1.0kHz 115 112 117 114 120 117
IIC Gas 1.4kHz 119 116 122 119 124 122
IIC & IIIC Gas & Dust 1.0kHz 110 107 112 109 115 112
IIC & IIIC Gas & Dust 1.4kHz 114 111 117 114 119 116

MEDC SM87JB Hazardous Area Loudspeakers

Technical Specification

Hazardous Area Certification
ATEX Ex d Gas Cert. no. Baseefa13ATEX0229X. Certified to: EN60079-0,1
Ex II 2G, Ex d IIC T4/T5/T6 Gb
ATEX Ex d Gas & Dust Cert. no. Baseefa13ATEX0231X. Certified to: EN60079-0,1,31
Ex II 2GD, Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
ATEX Ex de Gas Cert. no. Baseefa13ATEX0232X. Certified to: EN60079-0,1,7
Ex II 2G, Ex de IIC T4/T5/T6 Gb
ATEX Ex de Gas & Dust Cert. no. Baseefa13ATEX0233X. Certified to: EN60079-0,1,7,31
Ex II 2GD, Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
IECEx Ex d G Cert. no. IECEx BAS 13.0112X. Certified to: IEC60079-0,1
Ex d IIC T4/T5/T6 Gb
IECEx Ex d Gas & Dust Cert. no. IECEx BAS 13.0113X. Certified to: IEC60079-0,1,31
Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
IECEx Ex de Gas Cert. no. IECEx BAS 13.0114X. Certified to: IEC60079-0,1,7
Ex de IIC T4/T5/T6 Gb
IECEx Ex de Gas & Dust Cert. no. IECEx BAS 13.0115X. Certified to: EN60079-0,1,7,31
Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
UL Haz Locs UL certified for USA and Canada, listing no. E203310
Class I, Div 2. T4/T5/T6, Groups A-D. Class I, Zone 1, Ex d IIC / AEx d IIC Gb
Class II, Div 1. T135°C/T100°C/T85°C, Groups E,F&G (Canada only*)
Class II, Div 2. T135°C/T100°C/T85°C, Groups F&G. Zone 21 AEx tb IIIC
Class III Div 1 *Contact T&D  for ordering details
UL Ord Locs UL certified for USA and Canada, listing no. S8847
TR CU Ex d Gas 1Ex d IIC T4/T5/T6 Gb
TR CU Ex d Gas & Dust 1Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db
TR CU Ex de Gas 1Ex de IIC T4/T5/T6 Gb
TR CU Ex de Gas & Dust 1Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db
Russian Fire Approval All TR CU certified units are Russian Fire Approved
CQST Ex d Gas Ex d IIC T4/T5/T6 Gb
CQST Ex d Gas & Dust Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db
INMETRO Ex d Gas Ex d IIC T4/T5/T6 Gb
INMETRO Ex d Gas & Dust Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
INMETRO Ex de Gas Ex de IIC T4/T5/T6 Gb
INMETRO Ex de Gas & Dust Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
SIL SIL 2 certification to IEC61508. Cert number 20151119-4786827453
Type approval DNV (IEC60945)
Specifications
Material Ex enclosure – flame retardant, UV stable, glass reinforced polyester
Flare – flame retardant, high impact, UV stable, thermoplastic polyester
(UV stability tested to ISO 4892 part 3)
Hardware – bracket, fixings and captive cover screws in 316 stainless steel
Fire retardancy Body – glass reinforced polyester. V0 flammability rating
Outer flare – thermoplastic polyester. V0 flammability rating
Finish Body – natural black. Flare – natural black, natural red or painted as specified
(Black short flare painted black)
Rated power 8W, 15W or 25W (other ratings available, contact T&D)
Frequency range Frequency response 350Hz to 8kHz
8W and 15W units are available for use @ 200Hz
Weight Ex d/UL – 5.0kg, Ex de – 5.8kg. Based on long flare with transformer
Ingress protection IP66 & IP67, NEMA 4X & 6. (IPx7 & NEMA 6 on terminal chamber only)
Earth continuity Optional for Ex de version. Not available on Ex d unit
Entries Up to 2 x M20 or 1/2” NPT. Blanking plug available
Terminals Ex d – 8 x 2.5sqmm (4sqmm solid conductor)/ 12AWG. Ex de – 8 x 4.0sqmm
Mounting arrangement Stainless steel bracket with ratchet facility, optional swivel bracket available
Labels Optional duty and tag labels available
Dispersion angle Long flare (short in brackets), -6dB, 1kHz = 140º (240º), 4kHz = 40º (50º)
Driver impedance
SPL 1W/1m (sensitivity) IIC long flare, 1kHz – 106dB, 1.4kHz – 110dB
Certified temperature
Protection type Minimum Temp  Maximum Temperature
All units 8W unit 15W unit 25W unit
Ex d/UL -55°C +70°C +65°C +55°C
Ex de -50°C

EATON DB4B – ORDERING REQUIREMENTS

The following code is designed to help in selection of the correct Eaton hazardous area loudspeakers with ATEX approval and certification. Build up the part number by inserting the code for each component into the appropriate box.

Eaton DB4B - Ordering Requirements

Eaton DB4B – Ordering Requirements

ATEX Loudspeakers

ATEX Loudspeakers

Eaton MEDC

Eaton MEDC have developed ATEX products designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment. T&D distribute the extensive range of Eaton MEDC ATEX Certified manual call points, visual, audible alarms, loudspeakers and telephones for hazardous area workplaces, including Zone 1 & Zone 2 explosive atmospheres.

Thorne & Derrick, are the Explosive Atmosphere Experts, distributing an extensive range of ATEX Certified Equipment including heat tracing cables and systems, electrical heating products, electrical enclosures and plug/sockets outlets.

Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.

Cable Cleats | Cable Lugs | Cable Transits | Cable Joints

 

Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical

Data Sheets