ATEX Detectors, Control & Distribution Units Zone 1 & Zone 2 Control Station Weatherproof Ex ed – Eaton GHG 411 82

ATEX Detectors, Control & Distribution Units Zone 1 & Zone 2 Control Station Weatherproof Ex ed – Eaton GHG 411 82

ATEX Detectors, Control & Distribution Units Zone 1 & Zone 2 Control Station Weatherproof Ex ed – Eaton GHG 411 82

Eaton MEDC GHG 411 82 are ATEX control & distribution junction boxes intended for use in potentially explosive atmospheres in ATEX & IECEx Zone 1 and Zone 2 hazardous areas – suitable for use in all gas groups including hydrogen. (Except Acetylene Class I, Zone 1)

These control & distribution stations are manufactured from a UV stable, impact resistant polyamide; cover fixing screws are stainless steel thus ensuring a corrosion-free product.

The GHG 411 82 range comprises a 1,2 and 3 way unit offering a compact footprint.

The high ingress protection rating makes this range of control stations suitable for use in harsh environmental conditions.

Eaton GHG 411 82

Eaton GHG 411 82

ATEX Detectors, Control & Distribution Units

Zone 1 & Zone 2

ATEX Detectors, Control & Distribution Units

ATEX

Features

  • Zones 1,2 and safe area.
  • Exed IIC T6.
  • ATEX approved Ex II 2GD.
  • PTB Certified.
  • UL Listed for USA and Canada.
    • Class I, Div 2, Groups A-D
    • Class I, Zone 1, AExde IIB+H2 T6
    • Class II, Div 1, Groups E,F&G(cUL)
  • IP65 & IP66*.
  • Certified temperature: –55°C to +50°C*.
  • Impact resistant thermoplastic.
  • Retained stainless steel cover screws.
  • Variety of components.
  • Variety of enclosures.

*Depending on version.

Eaton MEDC GHG 411 82 - Dimensions

Eaton MEDC GHG 411 82 – Dimensions

Eaton MEDC GHG 411 82

Typical Configurations

Built-in components Weight Approx Order No.*
2 x pushbutton, 1NO + 1NC each, label: O, I, START, STOP 0.54kg MEDC GHG 411 8295 R0001
1 x signal lamp, 20-254V AC/DC, lens cover; white, red, green, yellow
1 x double pushbutton, 1NO + 1NC, label: O, I, START, STOP
0.65kg MEDC GHG 411 8295 R0003
1 x double pushbutton, 1NO + 1NC, label: O, I, START, STOP
1 x mushroom head latching, 1NO + 1NC, ”Emergency stop”
0.57kg MEDC GHG 411 8295 R0016
1 x control switch, 1 x change-over, label: O – I
1 x mushroom head latching, 1NO + 1NC, “Emergency stop”
0.57kg MEDC GHG 411 8295 R0017
1 x signal lamp, 20-254V AC/DC, lens cover: white, red, green, yellow
1 x key operated switch, 2 NO, label: I – O – II
0.65kg MEDC GHG 411 8295 R0008

*Note: Ordering codes are for ATEX compliant units only – for CSA listed units contact sales office.

MEDC GHG 411 82 Hazardous Area Control & Distribution Units

Technical Specification

Hazardous Area Certification CENELEC EN60079
Exed IIC T6.
(Tamb 48ºC). Zones 1 & 2.
CSA Listed for USA and Canada.†
Material Impact resistant thermoplastic, anti-static enclosure with stainless
steel cover screws
Finish Self coloured black
Signal Lamps Available in two voltage ranges:
Universal Voltage 20-254V AC/DC (current consumption 4-15mA).
Low Voltage 12-24V DC (maximum current consumption 24mA).
Lamp colours available: white, yellow, red, blue, green.
Certified temp -55ºC to +50ºC. Versions with switch -55ºC to +45ºC
(ATEX version).
See separate US data sheet for CSA operating temperatures.
Weight From 0.5kg to 1.3kg (411 Range).
From 0.8kg to 1.6kg (432 & 434 Range).
Ingress protection IP66 (IP65 for double pushbutton).
Entries 411 Range.
1 x M20 entry bottom as standard.
2 x M20 entries on bottom face available via brass gland continuity
plate.
432 & 434 Range.
2 x M20 entries in bottom as standard
(one blanking plug as standard).
Multi-way units Enclosures can be coupled together.
Actuator Types Spring return pushbutton, mushroom head emergency stop, mush
room head momentary, double pushbutton, key operated switches,
mini control switch and rotary switches.
Termination 2.5sqmm max. direct to components.
Alternatively pre-wired to a 6 way terminal block accepting up to
4sqmm conductors.
Max voltage rating 400V
Relay initiate Available on all versions – operates with 24V d.c. initiate supplies
only.
Function Labelling Each cover component can have a function label as extra
Labels Duty or tag labels are self adhesive
Options/accessories Lift flap, function label, terminal block, potentiometer, duty/tag
labels.
ATEX Detectors, Control & Distribution Units

ATEX Detectors, Control & Distribution Units

High Voltage Electrical Equipment

To support the safe and reliable distribution of Medium & High Voltage Electricity in industrial non-hazardous and hazardous area locations, Thorne & Derrick distribute a complete range of MV HV Electrical Connectors, Joints & Terminations including ATEX Certified variants for installation in Zone 1 & Zone 2 explosive atmospheres.

Data Sheets