Flameproof Plugs | Ex d Plugs & Sockets for Hazardous Areas | ATX PRD

Flameproof Plugs | Ex d Plugs & Sockets for Hazardous Areas | ATX PRD
Flameproof Plugs & Sockets
Product Category: Flameproof Plugs & Sockets | ATEX Certified | Zone 1 & Zone 2 Hazardous Areas
PRD Series 16, 32, 80 and 125 Amp Flameproof Plugs and Sockets manufactured by Appleton ATX are designed for hazardous areas where weatherproof and robust equipment is required. These flameproof plugs and sockets are certified for hazardous areas Zones 1, 2, 21 and 22. The PRD series of plug and socket assemblies provides safe, reliable power for portable or stationary electrical equipment such as lighting and heating systems, conveyors, motor starters, air-conditioning appliances, compressors and pumps.
The 16 Amp plug has a flameproof seal with cylindrical spigot joint, automatic disconnection of the poles once the plug is removed from the socket outlet by the patented dual safety device and the cover can be padlocked.
PRD 32 Amp flameproof seal also features a cylindrical spigot joint, with a mechanical interlocking device ensures disconnection within the flameproof chamber before the plug is removed. The plug cannot be removed when energized.
80 Amp and 125 Amp plugs feature an interlocking mechanical device which prevents the switch from closing until the plug is fully inserted into the wall socket or being removed until the switch is off. Socket outlet supplied with a load break isolating switch. The switch handle can be padlocked.
Flameproof Sockets Selection
- Wall Sockets — 16 A: 2 x M20 threaded cable entries (1 at the top, 1 at bottom). Supplied with one M20 plug. Connection on 2 x 4 mm² (0.003 x 0.006 in²) terminals. Earth terminals: internal and external, with 4 mm (0.16 in) diameter screws
- Wall Sockets — 32 A: 2 x M25 threaded cable entries (1 at the top, 1 at bottom). Supplied with one M25 plug. Connection on 10 mm² (0.016 in²) terminals. Earth terminals: internal and external with 6 mm (0.24 in) diameter screws
- Wall Sockets — 80 A: 1 x M32 threaded cable entry (on the top side). Connection via 8 mm (0.32 in) diameter lug terminals (not supplied). Internal earth through 35 mm² (0.054 in²) connection and external earth through 6 mm (0.24 in) diameter screws
- Wall Sockets — 125 A: 1 x M50 threaded entry (on the top side). Connection via 8 mm (0.32 in) diameter lug terminals (not supplied). Internal earth through 35 mm² (0.054 in²) connection and external earth through 6 mm (0.24 in) diameter screws
Flameproof Plug Selection
- Flameproof Plugs — 16 A: 1 cable entry through integrated M25 cable gland. 9 to 12 mm (9 to 12 in) diameter for the 2P+E plug. 12 to 15 mm (0.47 to 15 in) diameter for the 3P+E plug. 15 to 17 mm (0.59 to 0.70 in) diameter for the 3P+N+E plug. Connection on 2.5 mm ² (0.004 in ²) maximum terminals
- Flameproof Plugs — 32 A: 1 cable entry via integrated cable gland diameter 17 to 22 mm (0.70 to 0.87 in). Connection on 6 mm² (0.009 in²) maximum terminals
- Flameproof Plugs — 80 A: 1 cable entry via supplied cable gland diameter 18 to 28 mm (0.71 to 1.1 in). Connection on 16 mm² (0.025 in²) maximum terminals
- Flameproof Plugs — 125 A: 1 cable entry via supplied cable gland diameter 30 to 36 mm (1.18 to 1.42 in). Connection on 35 mm² (0.054 in²) maximum terminals
♦ See our complete range of ATEX Plugs for hazardous area electrical power distribution at low voltage – this includes flameproof plugs according to the Ex d Explosion Protection concept.
Ex d IIC | Â Appleton ATX Order Code | |
Flameproof Wall Socket | Flameproof Plug | |
2P + E – 16A – 20/25 Vac 50/60 Hz – Purple | PRD316RP | PRD316PP |
2P + E – 16A – 100/130 Vac 50/60Hz – Yellow | PRD316RY | PRD316PY |
2P + E – 16A – 200/250 Vac 50/60Hz – Blue | PRD316RB | PRD316PB |
3P + E – 16A – 380/415 Vac 50/60Hz – Red | PRD416RR | PRD416PR |
3P + N + E –Â 16A – 380/415 Vac 50/60Hz – Red | PRD516RR | PRD516PR |
3P + E – 32A – 380/415 Vac 50/60Hz – Red | PRD432RR | PRD432PR |
3P + E – 80A – 380/415 Vac 50/60Hz – Red | PRD480RR | PRD480PR |
3P + E – 125A – 380/415 Vac 50/60Hz – Red | PRD412RR | PRD412PR |
Flush Sockets for Mounting on Ex d IIb & IIC Enclosures | Ex d IIC | Ex d IIB |
2P + E – 16A – 20/25 Vac 50/60 Hz – Purple | Â PRD316FPC | Â PRD316FPB |
2P + E – 16A – 100/130 Vac 50/60Hz – Yellow | Â PRD316FYC | Â PRD316FYB |
2P + E – 16A – 200/250 Vac 50/60Hz – Blue | Â PRD316FBC | Â PRD316FBB |
3P + E – 16A – 380/415 Vac 50/60Hz – Red | PRD416FRC | PRD416FRB |
3P + N + E –Â 16A – 380/415 Vac 50/60Hz – Red | PRD516FRC | PRD516FRB |
3P + E – 32A – 380/415 Vac 50/60Hz – Red | PRD432FRC | PRD432FRB |
Plugs & Sockets
Specifications
- Hazardous Area Classification: Zone 1 and 2 – 21 and 22; Ex II 2 GD or II 2 G; IP66 or IP55; IK10
- Voltage: 20/25 Vac, 100/130 Vac, 200/250 Vac or 380/415 Vac
- Number of Poles: 2, 3
- Number of Wires: 3, 4, 5
- Hertz: 50/60 Hz
- Materials and Finishes:Â Enclosure and receptacle 16 and 32 A wall sockets are grey painted marine grade aluminum alloy. 32 A flush socket is cast iron. 80 and 125 A wall sockets are painted cast iron with marine anti-corrosion treatment. All plugs are grey painted marine grade for onshore and offshore distribution of LV power and electricity.

Lighting | Control Stations | Plugs & Sockets | Junction Boxes | Hazardous Area ATEX Certified Electrical Equipment for Explosive Atmospheres | Zone 1 & Zone 2