Increased Safety Junction Boxes | Hazardous Area Zones 1 2 21 22 | Appleton ATX JBEP Series

Appleton ATX JBEP

Appleton ATX JBEP Series FRP Terminal Increased Safety Junction Boxes for Electrical and Power Applications

increased safety Junction Boxes

appleton atx jbep

Product Category: Junction Boxes | ATEX Certified | Zone 1 & Zone 2 Hazardous Areas

Appleton ATX JBEP Series are fibreglass reinforced polyester terminal Increased Safety junction boxes for electrical and power applications, manufactured by Appleton ATX, are factory drilled and equipped. They are ideal for lighting and distribution applications in Zone 1 and 2, 21 and 22 hazardous areas.

The enclosures feature pillar (live mantle clamping), miniature or screw terminals for use with both armored and unarmored cable. Cable glands are supplied as standard with unarmoured cable versions, and are available as an option with armoured cable versions.

The JBEP Series of Increased Safety junction boxes are designed for motor and power distribution applications in Zone 1 and 2 (Gas)  and Zone 21 and 22 (Dust). These enclosures can be supplied with 16 mm² to 240 mm² terminals in multiple configurations, ideal for use in onshore and offshore wet or corrosive atmospheres such as petroleum refineries, chemical refineries and other industrial process facilities with hazardous area locations according to ATEX or IECEx.

The JBEP Series by Appleton ATX is also suitable for use in hazardous area Zone 21 or 22 areas, where flammable dusts are present either continuously or intermittently such as food processing, dairy, brewing and silos.

increased safety junction boxes

Specifications

  • NEC/CEC Certifications and Compliances: Class I, Zone 1, AEx e IIC, T5 or T6; Ex e IIC, T5 or T6; IP66
  • ATEX/IECEx Certifications and Compliances: Zone 1 and 2 – 21 and 22; Ex II 2 GD; IP66; IK10
  • Standard Materials: Static resistant carbon filled fiberglass reinforced polyester (FRP) enclosure with stainless steel hardware. Silicone gasket for sizes 85 x 85, 120 x 120 and EPDM (ethylene propylene diene monomer rubber) gasket for other sizes
  • Zones 1 and 2 Temperature Class: T6 for Ta ? +40 °C (+104 °F) and T5 for Ta ? +60 °C (+140 °F)
  • Zones 21 and 22 Surface Temperature: T60 °C (T140 °F) for Ta ? +40 °C (+104 °F), T90 °C (+194 °F) for Ta ? +60 °C (+140 °F)
  • Ambient Temperatures: : -55 °C ≤ Ta ≤ +60 °C ( -67 °F ≤ Ta ≤ +140 °F)
  • Ambient Temperatures: Glands: Type 757: -60 °C to +100 °C (-40 °F to +212 °F). Type EEXe: -20 °C to +55 °C (-4 °F to +131 °F). Type E1FX, E2FX, E1FW, E2FW, T3, A2F: -60 °C to +130 °C (-76 °F to +266 °F). Type PX, PX2K: -60 °C to +10
  • Ambient Temperatures: Terminals: Type WDU, WFF: -50 °C to +120 °C (-58 °F to +248 °F). Type SAK, AKZ: -50 °C to +100 °C (-58 °F to +212 °F)
  • Ambient Temperatures: Drain/Breather: Type DBE: -50 °C to +85 °C (-58 °F to +185 °F)

increased safety JUNCTION BOXes

Selection

Junction Box – 4 terminals & 2 earth terminals 4mm² – Configuration: P + N (1PE + 2L + 2N + 1PE)

Increased Safety Junction Boxes Junction Box Layout Appleton ATX Order Code
3 x M20 with earth continuity sheet Appleton ATX JBEP080806AE03
3 x M20 with cable glands for unarmored cable (diameter 6.5 to 14.5mm) Appleton ATX JBEP080806NE03
4 x M20 with earth continuity sheet Appleton ATX JBEP080806AE05
4 x M20 with cable glands for unarmored cable (diameter 6.5 to 14.5mm) Appleton ATX JBEP080806NE05

Junction Box – 4 terminals & 2 earth terminals 4mm² –  Configuration: P + N (1PE + 1 + 2 + 3 + 4 + 1PE)

Increased Safety Junction Box Junction Box Layout Appleton ATX Order Code 
2 x M20 with earth continuity sheet Appleton ATX JBEP080806AE22

Junction Box – 6 screw terminals & 2 earth terminals 4mm² –  Configuration: P + N (1PE + 1 + 2 + 3 + 4 + 5 + 6 + 1PE)

Increased Safety Junction Box Junction Box Layout Appleton ATX Order Code
4 x M20 with earth continuity sheet Appleton ATX JBEP080806AE24

Junction Box – 6 screw terminals & 2 earth terminals 4mm² –  Configuration: TP (1PE + 2L1 + 2L2 + 2L3 + 1PE)

Increased Safety Junction Box Junction Box Layout Appleton ATX Order Code
4 x M20 with earth continuity sheet Appleton ATX JBEP121209AE25
4 x M25 with cable glands for unarmored cable (diameter 8 to 17mm) Appleton ATX JBEP121209NE26
4 x M20 with earth continuity sheet Appleton ATX JBEP121209AE27
4 x M25 with cable glands for unarmored cable (diameter 8 to 17mm) Appleton ATX JBEP121209NE28

Junction Box – 4 screw terminals & 2 earth terminals 6mm² –  Configuration: P + N (1PE + 2L + 2N + 1PE)

Increased Safety Junction Box Junction Box Layout Appleton ATX Order Code
4 x M20 with earth continuity sheet Appleton ATX JBEP121209AE45
4 x M25 with cable glands for unarmored cable (diameter 8 to 17mm) Appleton ATX JBEP121209NE46
4 x M20 with earth continuity sheet Appleton ATX JBEP121209AE47
4 x M25 with cable glands for unarmored cable (diameter 8 to 17mm) Appleton ATX JBEP121209NE48

Junction Box – 8 terminals & 3 earth terminals 6mm² – Configuration: TP + N (2PE + 2L1 + 2L2 + 2L3 + 2N + 1PE)

Junction Box Junction Box Layout Appleton ATX Order Code
4 x M20 with earth continuity sheet Appleton ATX JBEP171709AE10
4 x M25 with cable glands for unarmored cable (diameter8 TO 17mm) Appleton ATX JBEP171709NE10
4 x M20 with earth continuity sheet Appleton ATX JBEP171709AE11
4 x M25 with cable glands for unarmored cable (diameter 8 to 17mm) Appleton ATX JBEP171709NE11

Junction Box – 12 terminals & 3 earth terminals 6mm² – Configuration: TP + N (2PE + 3L1 + 3L2 + 3L3 + 3N + 1PE)

Junction Box Junction Box Layout Appleton ATX Order Code 
6 x M20 with earth continuity sheet Appleton ATX JBEP202110AE12
6 x M25 with cable glands for unarmored cable (diameter 8 to 17mm) Appleton ATX JBEP202110NE12

ATEX Certifications and Compliances

The following information relates to the hazardous area certification and approvals for this range of junction boxes for specification purposes – should you require any further information please contact Thorne & Derrick.

Ex e

Ex e Junction Boxes

Certfication Type JBEP
— Gas, Zone 1 and Zone 2: Conforming to ATEX 94/9/EC: II 2G
– Conforming to IECEx : EPL Gb
– Type of Explosion Protection: Ex eb IIC
– Temperature Class: T6 for Ta ≤ +40 °C (+104 °F) and T5 for Ta ≤ +60 °C (+140 °F)
— Dusts, Zone 21 and Zone 22:
– Conforming to ATEX: II 2D
– Conforming to IECEx: EPL Db
– Type of Explosion Protection: Ex tb IIIC
– Surface Temperature : T60 °C (T140 °F) for Ta ≤ +40 °C (+104 °F), T90 °C (+194 °F) for Ta ≤ +60 °C (+140 °F)
• Ambient Temperatures: -55 °C ≤ Ta ≤ +60 °C ( -67 °F ≤ Ta ≤ +140 °F)
• ATEX Certificate : LCIE 12 ATEX 3037X
• EC Declaration of Conformity : 50291
• IECEx Certificate : IECEx LCIE 13.0003X
• Index of Protection according EN/IEC 60529: IP66

Ex d Flameproof Enclosures

Thorne & Derrick, The Explosive Atmosphere Experts, stock and distribute a complete range of Ex d Enclosures and Plugs & Sockets from leading manufacturers including Marechal and Technor. For Flameproof Ex d applications please see flameproof plugs and also Ex d junction boxes.

Hazardous Area Lighting Control Station Plug Junction Box

Lighting | Control Stations | Plugs & Sockets | Junction Boxes | Hazardous Area ATEX Certified Electrical Equipment for Explosive Atmospheres | Zone 1 & Zone 2

Data Sheets