Flexible Heating Cable | Eltherm ELK-H-4.0 | Trace Heating Cable High Temperature Heating up to 450°C

Eltherm ELK-H Heater Cable – Resistance Heating Process Temperature Maintenance

Flexible Heating Cable | Eltherm ELK-H Heater Cable – Resistance Heating Process Temperature Maintenance

Eltherm ELK-H resistance heating cables and tapes provide process temperature maintenance and frost protection to vessels, pipes, valves and small components up to 450° Celsius.

Please Note: This product has been discontinued. Please Contact Thorne & Derrick for an alternative!

Flexible Heating Cable – ELTHERM ELK-H

SPECIFICATION

  • Nominal Supply Voltage : 230V
  • Maximum Output : 125 w/m
  • Maximum Operating Temperature : 450ºC
  • Minimum Installation Temperature : Not restricted
  • Diameter: 3.5-4.5mm
  • Minimum Heater Cable Bend Radius (Flat): 8mm
  • Insulation : E-Glass Textile
  • Cold Lead Length (Both Ends) : 1.2m without plug
  • Moisture Proof : No
  • Protection Class: Depending on installation
  • Manufactured According To : DIN VDE 0721 T2
  • Final Inspection According To: DIN VDE 0721 T2, 1.5kV AC – 1 min
  • Heating Cable Type : Resistance flexible heating cable

flexible Heating Cable  – Eltherm ELK-H

SELECTION TABLE

Contact T&D for technical guidance, heat loss calculations for pipework systems and optimum specification of the correct trace heater cable for your application.

Flexible heating cable application : frost protection and process heating.

Eltherm ELK-H Designation Heated Length (m) Nominal Output (W) Eltherm Order Code
ELK-H-4.0 4.0 490 0140019

Other lengths of ELK-H resistance flexible heating cables are available upon request.
Resistance Tolerance: +/- 5%
Lengths tolerance ± 2%, max ± 0.25m

flexible heating cable – Eltherm ELK-H

Applications

  • Heat tracing on apparatus, appliances and systems
  • Glass devices and systems with high output needs
  • Laboratory applications

Eltherm ELK-H flexible heating cables provide temperature maintenance and frost protection to pipework and mechanical services in all industries – typical applications include industrial and hazardous area heating of process pipework, instrument lines and storage tanks to maintain viscosity or prevent frost damage as an integral work-task of plant Winterisation.

Eltherm ELK-H Heater Cable

T&D provide value-added design services for process heating using trace heating cables and systems. Heating cables using constant wattage, self-regulating, mineral insulated and resistance heating technology provide frost protection and temperature maintenance to pipework, drums, tanks, IBC’s and valves.

RESISTANCE HEATING CABLES

Eltherm resistance heating cables are manufactured from a high-resistance heating conductor, PTFE insulated with protective braid and fluoropolymer outer jacket. Powered at specific voltage the resistance heat generated by the conductors provides electrical trace heating to pipes and vessels. Resistance heating cables will “burn-out” if overlapped unlike self-regulating trace heating cables.

High temperature resistance heating cables insulated with glass fibre provide electrical heating up to 800° Celsius.

Eltherm

Eltherm – Heating Cables, Heated Hoses, Surface Heating Mats & Drum Heaters

Eltherm ELK-H Heater Cable

T&D – Eltherm Heating Cables Distributor

Data Sheets