EXHEAT MTH Mini Tank Immersion Heaters – ATEX Certified Zone 1 & Zone 2, Zone 21 & Zone 22
EXHEAT Hazardous Area Immersion Heaters ATEX, IECEx & UKEx
ATEX Immersion Heater | Zone 1 & 2 (IIA, IIB, IIC), Zone 21 & 22 (IIIA, IIIB, IIIC)
Hazardous Area Immersion Heater
ATEX Certified
EXHEAT MTH mini tank hazardous area immersion heater provide certified heating for Zone 1 & Zone 2 (Flammable Gas) and Zone 21 & Zone 22 (Dust) hazardous areas and explosive atmospheres according to ATEX Directive. For hazardous area applications is part of the smaller range of immersion heaters which provide an ideal solution when space is minimal.
Typical applications for the EXHEAT MTH mini tank immersion heater include tank heating for oil and water, frost protection and boiler equipment.
The immersion heater is suitable for applications with ambient temperatures as low as -60°C. The heater also has different sized withdrawable cartridge elements available, and optional built in thermocouple for over-temperature protection.
The MTH immersion heater range is fully certified for use in hazardous areas where the atmosphere is classified as a Zone 1 or 2 (IIA, IIB, IIC) gas group, or a Zone 21 or 22 (IIIA, IIIB, IIIC) dust group.
Features of EXHEAT MTH Immersion Heaters
- ‘Plug and play’ style immersion heater, screws directly to tank or boss as required
- Mounting Installation – horizontal or vertical installation
- Fully integrated PCB to control the over temperature, thermometer chip as well as the thermocouple for process control
- Suitable for ambient temperatures as low as ≤40°C to ≤60°C
- Long term stability
- Variable length elements and duties
- 1/2″ BSP or NPT fixing as standard – Suitable to work with most adaptors
- Fully 321 stainless steel elements and fixing. Optional materials including NACE requirements available on request
- Suitable for working pressures up to 18.3 bar g
EXHEAT MTH Mini Tank Immersion Heaters
EXHEAT MTH Hazardous Area ATEX Certification & Installation
Certification:
ATEX / IECEx / UKEx
II 2 G/D
ATEX Certified Immersion Heaters (Hazardous Area Zone 1 & Zone 2)
Ex d IIC T6 Gb
Ex tb IIIC T85°C….T450°C Db (IP66/68)
The EXHEAT MTH hazardous area immersion heater can be installed horizontally and vertically.
The ‘plug and play’ style Mini Tank Immersion Heater screws directly to tank or boss as required.
EXHEAT Miniature Tank Heater (MTH) – Dimensions & Features
EXHEAT MTH Hazardous Area Immersion Heater – Applications
Applications for these electric heaters include:
EXHEAT Stockist – Worldwide Delivery, Competitive Quotations
- Boiler equipment
- Cleaning and rinsing tanks
- Crank casings
- Frost protection
- Gear boxes
- Hot water storage tanks
- Motor enclosures
- Pump casings
- Sumps
- Tank bases
EXHEAT MTH Mini tank ATEX Immersion Heater Specifications
- Cable – 3m standard – longer available on request
- Element Options – Available in 10mm, 16mm and 20mm sheathed variants
- Materials – Body: Anodised aluminium 6082 T6Boss: Stainless steel 316Element: Stainless steel 316
- Mounting – Threaded SS316 boss suited to client requirements. Available in a range of sizes in BSP, NTP and Metric fittings
Suitable for Oil & Water Applications
Model | Rating (W) | Immersed Length (mm) | Inactive Length (mm) | Surface load (W/cm²) | Fixing | Element | ||||||
220V | 230V | 240V | 254V | 220V | 230V | 240V | 254V | |||||
MTH-0.1-6-RNS | 91 | 100 | 109 | 122 | 160 | 30 | 1.61 | 1.77 | 1.93 | 2.16 | 1/2″ NPT/BSP | 15mm |
MTH-0.2-11-RNS | 183 | 200 | 218 | 244 | 270 | 30 | 1.69 | 1.85 | 2.01 | 2.25 | 1/2″ NPT/BSP | 15mm |
MTH-0.3-15-RNS | 274 | 300 | 326 | 366 | 380 | 30 | 1.71 | 1.87 | 2.03 | 2.28 | 1/2″ NPT/BSP | 15mm |
MTH-0.4-20-RNS | 366 | 400 | 435 | 489 | 500 | 30 | 1.69 | 1.85 | 2.01 | 2.26 | 1/2″ NPT/BSP | 15mm |
MTH-0.5-24-RNS | 457 | 500 | 544 | 610 | 620 | 30 | 1.67 | 1.83 | 1.99 | 2.23 | 1/2″ NPT/BSP | 15mm |
* 30mm inactive from fixing 10mm inactive at tip where thermocouple is placed
Please contact our Sales Team to discuss the full range of options available.
Air Heaters | Immersion Heaters | Line Heaters | Thermostats | ATEX & IECEX Certified Electrical Heaters
T&D – Experts in Equipment for Explosive Atmospheres
Trust Thorne & Derrick to specify and supply from stock safe and reliable Heat, Light & Power Products for use in hazardous area locations and explosive atmospheres certified to international standards including ATEX and IECEx – this includes Zone 1 / Zone 2 (Flammable Gas) or Zone 21 / Zone 22 (Dusts) and Class I, Division 1 and Division 2 hazardous area requirements.
Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.
Lighting | Sockets | Glands | Control Stations | Isolators | Push Buttons | Hazardous Area Equipment UK & Export Sales