ASCO 630 Solenoid Valves (Direct Acting) 3/2 NC-NO, Pad Mounting Valve – Hazardous Area Class II 1G Ex ia IIC T6, II 1D Ex iaD 20

ASCO 630 Solenoid Valves (Direct Acting) 3-2 NC-NO, Pad Mounting Valve – Hazardous Area Class II 1G Ex ia IIC T6, II 1D Ex iaD 20

ASCO 630 – Direct Acting/Operating Solenoid Valves For Hazardous Areas & Potentially Explosive Atmospheres

 

ASCO 630 hazardous area solenoid valves are direct acting/operating type valves suitable for hazardous areas installation with international classifications including ATEX, UL, CSA and other local approvals on request.

3/2 – Way Solenoid Valve

NC – Normally Closed Valve

NO – Normally Open Valve

Via ASCO Numatics FASTSHIP and SAMEDAY Express Delivery Service we are able to deliver 2,000+ ASCO valves from stock direct to you.

T&D are an Authorised UK Distributor for ASCO Numatics, part of Emerson Industrial Automation.

 

ASCO 630 SOLENOID VALVES

  • Miniature, ultra-low power valves for use in potentially explosive atmospheres according to ATEX Directive 94/9/EC
  • EC type examination certificate (IBExU01ATEX1060 X) and IECEx certificate (IECEx IBE 13.0011X) are in compliance with the International and European Standards IEC and EN: 60079-0, 60079-11 and 60079-26
  • Intrinsically safe design (class Ex ia) approved for use in potentially explosive atmospheres of group IIC and temperature class T6. It can be suitable for oil, gas, paint manufacturing and application industries
  • Specially designed for applications where there is a requirement for low power consumption, low weight and low bulk combined with excellent flow/pressure characteristics. They can be used in zone 0, and are also perfectly suitable for other zones. Electrical connection can be made with cable or connector according to DIN 43650, form C, 9,4 mm pin spacing

Differential Pressure : 2 – 8 bar [1 bar = 100 kPa]

Response Time : NC 6V 780, 8V 650, 12V 320, 24V 130

NO 12V 320, 24V 130

Fluids Temperature Range (TS) Valve Seal Materials
air or inert gas dry, filtered (5 µm, 6V, 8V and 12 V versions, or 25 µm, 24V version), without condensate, dew point: -20°C -25°C to +50°C NBR Nitrile

ASCO 630 – VALVE FLUID CONTACT COMPATIBILITY

ASCO 630 Solenoid Valve
Body PPS
Internal parts Piezo ceramicsl
Seals NBR
Subbase Brass, PA or zinc diecast

ASCO 630 – VALVE ELECTRICAL CHARACTERISTICS

Electrical Safety : IEC 335

Standard Valve Voltages : DC (=) : 6V, 8V, 12V, 24V

ASCO 630 –  VALVE SPECIFICATIONS

Pipe size Flow coefficient Operating pressure differential (bar) Voltage Power ratings M ASCO Catalogue number
(m3 /h) (l/min) Min Max (V) = spade plug connection with connector with 2-lead outlet
= = =
NC – Normally closed (PISCIS prefix)
Pad Mounting 0.015 0.026 2 8 6 0.003 X ASCO 63000061 ASCO 63000062
ASCO 63000059 ASCO 63000060
0.002 0.033 2 8 8 0.022 X ASCO 63000091 ASCO 63000092
ASCO 63000093 ASCO 63000094
12 0.012 X ASCO 63000051 ASCO 63000055
ASCO 63000053 ASCO 63000057
0.032 X ASCO 63000095 ASCO 63000096
ASCO 63000097 ASCO 63000098
24 0.046 X ASCO 63000043 ASCO 63000047
ASCO 63000045 ASCO 63000049
0.125 X ASCO 63000099 ASCO 63000100
ASCO 63000101 ASCO 63000102
NO – Normally open
Pad Mounting 0.002 0.033 2 8 12 0.012 X ASCO 63000052 ASCO 63000056
ASCO 63000054 ASCO 63000058
24 0.46 X ASCO 63000044 ASCO 63000048
ASCO 63000046 ASCO 63000050

(M) : Type of manual operator: ✕ : without ▼ : impulse

ASCO 630 – VALVE OPTIONS

The solenoid valves can be mounted in any position without affecting operation

ASCO 630 solenoid valves are supplied with mounting screws

Pipe connections G 1/8 have standard thread according to ISO 228/1

Electrical connection between solenoid valve and barrier/interface with cable or connector

Installation/maintenance instructions are included with each valve

 

ASCO SOLENOID VALVES – ATEX, IEC EX & NEMA HAZARDOUS AREA CERTIFIED

ASCO Valves

ASCO Solenoid Valves For Hazardous Area Oil, Gas & Petrochem Industries (ATEX & IECEx) – call T&D for sales, technical and specification support on all ASCO valves.

Hazardous Area Equipment Certification - ATEX (Zone 1 Zone 2), IEC Ex, NEMA (Div 1 Div 2) & Explosion Protection

Image : Energy Reality - A Project of Post Carbon Institute. 

 

HAZARDOUS AREA CERTIFICATION

ATEX (ZONE 1 ZONE 2), IEC EX, NEMA (DIV 1 DIV 2) & EXPLOSION PROTECTION

➡ Did you know?  T&D supply ATEX hazardous area certified Analytic Gas Heated Hoses.

➡ Did you know? T&D distribute Hazardous Area Instrumentation Equipment as Approved Vendors to global oil and gas operators and their EPC’s.

 

Data Sheets