Xenoflash Lighting EV XN-MXN | ATEX Hazardous Area Lighting | TECHNOR

Xenoflash Lighting EV XN-MXN ATEX Hazardous Area
Xenoflash Lighting EV XN-MXN ATEX Hazardous Area
The TECHNOR (part of the Marechal Electrical Group) range of copper-free aluminium Xenoflash Lighting EV XN-MXN fixtures, approved with an IP rating of IP66, as well as being ATEX and IECEx certified as Hazardous Area Lighting, allowing for use in potentially explosive atmospheres, providing signals of high visibility in Zone 1 & Zone 2 (gas) and Zone 21 & Zone 22 (dust). Available in three visual signals lighting fixture variants EV XN-MXN, EVCC-XN-MXNÂ & EVA-XN-MXN, which are equipped with excellent corrosion resistance and Fresnel lens, available in varied luminous intensities up to 20J, providing flexible visibility to suit a wide range of hazardous areas.
The EVde XN-MXN version, paired with an integrated Ex e Junction Box, allows end users and contractors the possibility to save one junction box, two cable glands and a minimum of 30 minutes of labour during installation process. This version is supplied complete with adjustable AISI304 stainless steel mounting bracket suitable for ceiling, wall and suspension installation.
- Copper-free aluminium body and tempered glass lamp compartment ensure an excellent corrosion resistance
- EVCC version, without integrated Ex e junction box, allows standard ceiling installation (available upon request)
- EVA version, without integrated Ex e junction box, allows standard suspension installation by conduit system and pastoral pole (available upon request)
Xenoflash Lighting EV XN-MXN Technical Specifications
The following table provides a further insight on TECHNOR‘s Xenoflash Lighting EV XN-MXN ATEX Hazardous Area product specifications:
TECHNOR EV XN-MXN Technical Specifications | |
Material | Copper-free aluminium body and tempered glass |
IP Rating | IP66 |
Ambient Temperature Range | -60°C to +60°C |
Approvals | ATEX: INERIS 01ATEX0019X – IECEx: INE 15.0031X EAC: RU C-IT.BH02.B.OO616/2O |
Zones | Gas Zone: 1,2 Dust Zone: 21,22 |
Rated Operation Voltage (UE) | 240Vac, 12/24Vac/dc other voltages upon request |
Frequency (AC version) | 50/60Hz |
Colour Light | Other colours available upon request |
Hardware and Screw | w AISI316L stainless steel |
Coating | Painted by polyuretane painting: RAL5014 painting cycle C4suitable for On-Shore The reference standard is UNI EN ISO 12944 – 1: 2018 Upon request other colours and painting cycles |
Entries | N° 2 entries M25x1,5 (EVde and EVCC version) N° 1 entry M25x1,5 (EVA version plugs and cable glands excluded) Upon request M20, 3/4” and 1/2″ NPT |
Through Wiring | Loop-in / Loop-out (EVde and EVCC version) |
Plug | 1 x M25 plastic plug 1 x M25 brass nikel chrome plated plug c/w gasket (mounted) |
Accessories Upon Request | Mounting kit in AISI316L stainless steel: Pole mounting kit, from 1″ 1/2 up to 2″ Cable gland kit in brass nichel chrome or AISI316L stainless steel Protection guard in AISI316L stainless steel |
EV XN-MXN Hazardous Area Lighting Selection Guide
Xenoflash Lighting EV XN-MXN Product Range | Visual Signals
- Luminosity up to 8.500 cd
- In case of maximum ambient temperature reaches +40°C, temperature class changes into T5 (ordering code to be required)
- Other voltages and colors on request

Xenoflash Lighting EV XN-MXN Dimensions & Mounting Bracket
EV XN-MXN Code | Product Type | Power [W] | Luminous Intensity | Dimension [mm] | Voltage Rating | Colour Light | Weight [kg] | |||
A | B | C | D | |||||||
A040384500001 | TECHNOR EVDE-XN-3 | 6 | 6J | 194 | 370 | 214 | 584 | 240VAC 50/60HZ | RED | 4.50 |
A040384500003 | TECHNOR EVDE-MXN-3 | 16 | 16J | 194 | 370 | 214 | 584 | 240VAC 50/60HZ | RED | 4.50 |
A040584500002 | TECHNOR EVDE-MXN-5 | 20 | 20J | 281 | 501 | 214 | 715 | 240VAC 50/60HZ | RED | 6.00 |
A040384C00006 | TECHNOR EVDE-XN-3 | 6 | 6J | 194 | 370 | 214 | 584 | 12/24V AC/DC | RED | 4.50 |
A040384C00002 | TECHNOR EVDE-MXN-3 | 16 | 16J | 194 | 370 | 214 | 584 | 12/24V AC/DC | RED | 4.50 |
A040584C00002 | TECHNOR EVDE-MXN-5 | 20 | 20J | 281 | 501 | 214 | 715 | 12/24V AC/DC | RED | 6.00 |
Xenoflash Lighting EVA XN-MXN 5 Product Range
The following table provides a further insight on the EVA XN-MXN 5Â product range, accompanied with a product dimension example, which demonstrates the unique fixing capabilities:

Xenoflash Lighting EVA XN-MXN Dimensions
EVA XN-MXN Product Type | Dimensions [mm] | |
A | B | |
TECHNOR EVA-XN-3 | 194 | 302 |
TECHNOR EVA-MXN-3 | 194 | 302 |
TECHNOR EVA-MXN-5 | 281 | 433 |
Xenoflash Lighting EVCC XN-MXN 5 Product Range
The following table provides a further insight on the EVCC XN-MXN 5Â product range, accompanied with a product dimension example, which demonstrates the unique fixing capabilities:

Xenoflash Lighting EVCC XN-MXN Dimensions
EVCC XN-MXN Product Type | Dimensions [mm] | |
A | B | |
TECHNOR EVCC-XN-3 | 194 | 309 |
TECHNOR EVCC-MXN-3 | 194 | 309 |
TECHNOR EVCC-MXN-5 | 281 | 440 |
TECHNOR | Ex Lighting Specialist
TECHNOR, part of the MARECHAL group, are world specialists in Hazardous Area Lighting equipment, engineered solutions for industrial and Ex environments. TECHNOR offer a wide variety of Ex Lighting products alongside the Xenoflash Lighting EV XN-MXNÂ range, including, Linear LED Lighting, Linear Fluorescent Lighting, EV Wellglass Lighting, LED Spotlight, Floodlight Lighting, LED Lanterns, Lamps, Lanterns and more.
âž¡ Thorne & Derrick distribute from stock the most extensive range of ATEX Lights & Hazardous Area Lighting certified according to ATEX and IECEx for Zone 1 and Zone 2 lighting applications.