Rotronic CO2 Gas Measurement Display – Indoor Air Quality (IAQ) Monitor
Rotronic CO2 gas measurement display – Indoor air quality
Rotronic CO2 gas measurement display is a carbon dioxide measurement instrument suitable for wall mounting or bench top monitoring providing simultaneous monitoring and recording of CO2 levels.
The Rotronic CO2 gas measurement display is fitted with the Rotronic Hygromer IN-1 humidity sensor and can be configured directly with buttons and stored data can be exported with a USB stick for analysis.
Typical applications of indoor air quality monitoring include classrooms, meeting rooms, open-plan offices and shopping centers.
Rotronic CO2 Gas Measurement Display – Indoor Air Quality (IAQ) Monitor – Product Benefits
Features
- Display for mounting on walls or bench-top use
- Data recording function
Display
- Large, easy-to-read display of measured values
- CO2 indicator for quick recognition of air quality (GOOD/NORMAL/POOR)
- REC LED to indicate data recording is in progress
- Display of date and time
Use And Connections
- Readily accessible buttons for easy use
- USB access for data downloads
- 12 VDC power supply
Humidity Sensor And Calibration
- HYGROMER® IN-1 humidity sensor
- NDIR sensor with automatic calibration
- Calibration of CO2 at 0/400 ppm or any value between 0 and 990 ppm
- Calibration of humidity possible at 35/80 %RH
Rotronic CO2 Gas Measurement Display – Technical Specifications
Type | Wall or bench-top display |
Parameters | CO2, relative humidity and temperature |
Range of application | 0…50 °C / 0…95 %RH, non-condensing |
Power supply | AC adapter 12 VDC |
Clock | Real time clock |
Alarm/indicator | Adjustable for CO2 measurement |
Current consumption | 700 mA (max) |
Warm-up time | <1 min |
Memory capacity | 18,000 values with time stamp, automatic recording (%RH / °C / ppm) |
CO2 GAS MEASUREMENT & DETECTION INFORMATION
Measurement principle | Infrared (NDIR) with automatic calibration (ABC) |
Measurement range | 0…5000 ppm |
Accuracy at 23 °C ±5 K | ±30 ppm ±5 % of the measured value |
Response time | <3 min. diffusion time |
Adjustment points | 0, 400 ppm or any value between 0 and 990 ppm |
Pressure dependence | +1.6 % reading per kPa |
Null drift | <10 ppm/year |
Maintenance | No maintenance (standard indoor application) |
ROTRONIC – CARBON DIOXIDE GAS MEASUREMENT FOR VENTILATION MONITORING
Rotronic devices including transmitters, data loggers and hand held instruments are used for regulating ventilation in living areas, offices, classrooms, cinemas, hospitals and also for measuring CO2 pollution in garages, tunnels and logistics facilities. Rotronic carbon dioxide gas measurement instruments monitor indoor air quality (IAQ) safeguarding the health, productivity and comfort of occupants.
Image : Wired
ROTRONIC MEASUREMENT
View the current Rotronic catalogue :
HUMIDITY, DEW POINT, FLOW, PROCESS PRESSURE, CARBON DIOXIDE & TEMPERATURE MEASUREMENT
T&D distribute Rotronic probes, instruments, transmitters, data loggers, indicators and sensors for the measurement of dew point, flow, air velocity, process pressure, carbon dioxide and temperature. Click an icon for further information…..