Fisher V250 Full Bore Pipeline Ball Valve – Rotary Valves

Fisher V250 Full Bore Pipeline Ball Valve - Rotary Valves

Fisher V250 Full Bore Pipeline Ball Valve – Rotary Valves

Fisher V250 Valve is a full bore pipeline ball valve designed for heavy-duty throttling and on-off applications. The V250 valve is available with a single ball seal, flow ring, or dual-seal construction and depending on the size of the application the valve can be installed between CL600 or CL900 pipeline flanges.

The single seal construction of the V250 valve is used for tight shutoff applications and the double seal construction is used in bidirectional flow-shutoff applications.

The design of the Fisher V250 is typically used for applications in gas transmission lines, gas distribution, or liquid pipelines.

Fisher V250 Full Bore Pipeline Ball Valve – Product Features

  • High Pressure Drop Capabilities – depending on the construction, a Design V250 valve is capable of a maximum static pressure differential of 103 bar (1500 psi) at 82°C (180°F) for CL600, and 155 bar (2250 psi) for CL900 constructions at 38°C (100°F) for LCC steel and CF8M (316 stainless steel)
  • Efficient Operation – tapered-polygon ball-to-shaft connection and clamped splined actuator connection remove lost motion or deadband from the drive train for throttling control applications
  • Excellent Flow Control– reduced ball port design provides a modified equal percentage flow characteristic and an excellent response characteristic
  • Tight Shutoff – shutoff with the Design V250 ball seal is 0.0001 percent of maximum capacity.
  • Greater Capacities – design V250 ball valve construction offers greater capacities than conventional globe valves for both compressible and incompressible fluids
  • Sour Service Capability – materials are available for applications handling sour service. These materials comply with the requirements of NACE MR0175-2002
  • Long Service Life – pressure-balanced drive shaft design with PTFE-lined bearings and pressure-assisted shaft sealing arrangement provides for a long life of reliable service
  • Minimum Maintenance – two-piece ball and shaft assembly allows for complete trim overhaul; parts replacement is kept to a minimum
  • Excellent Environmental Capabilities – the optional live loaded packing system is designed with very smooth shaft surfaces and live loading to provide excellent sealing

FISHER V250 FULL BORE PIPELINE BALL VALVE

PRODUCT Specification

Available Valve Configurations Flangeless ball valve assembly with single ball seal, flow ring, or dual ball seal
Valve Body Sizes NPS 4 through 12 flangeless valves retained by line flange bolts and designed to fit between CL600 or CL900 raised-face or ring-type joint flanges (ASME B16.5) NPS 16 through 24 flangeless valves retained by line flange bolts and designed to fit between CL600 raised-face or ring-type joint flanges (ASME B16.5)
Maximum Inlet Pressure(1) NPS 4 through 12 consistent with CL600 or CL900 (ASME B16.34) NPS 16 through 24 consistent with CL600 (ASME B16.34)
Maximum Allowable Shutoff Pressure Drop(1,2) Flow Ring Construction: Limited by the pressure-temperature rating of the valve body
Shutoff Classification Single-Seal and Dual-Seal Constructions: 0.0001% of maximum valve capacity (less than 1% of Class IV, ANSI/FCI 70-2 and IEC 60534-4) Flow Ring Construction: 1% of maximum valve capacity
Seal Material Temperature Capability(1) Single-Seal and Dual-Seal Construction: –46 to 82°C (–50 to 180°F) for LCC steel and CF8M [316 stainless steel (SST)] valve bodies Flow Ring with Nitrile O-Rings: –46 to 93°C (–50 to 200°F) for LCC steel and CF8M valve bodies Flow Ring with Fluorocarbon O-Rings: –46 to 204°C (–50 to 400°F) for LCC steel and CF8M valve bodies F
Flow Direction Single Seal Construction: Forward-flow only,  Flow Ring Construction: Forward- or reverse-flow, Dual Seal Construction: Required to provide shutoff for bi-directional flow
Flow Characteristic Modified equal percentage
Maximum Ball Rotation 90 degrees
Actuator Mounting  Right-hand or left-hand mounted as viewed from the valve inlet for forward-flow
Valve Body/Actuator Action With diaphragm or piston rotary actuator, field-reversible between push-down-to-close (extending actuator rod closes valve body) and push-down-to-open (extending actuator rod opens valve body)
Options  Line flange bolts, Sour service trim, Buried service actuator adaptation, and Dual seal configuration for bi-directional shutoff (this configuration incorporates a tapped and plugged connection which can be used in a double block and bleed system to test seal integrity), Live Loaded PTFE Packing 1.

1. The pressure or temperature limits in this bulletin and any applicable standard or code limitations should not be exceeded. 2. The maximum allowable shutoff pressure drops are further limited for the following constructions. The NPS 12 with S20910 drive shaft is limited to 128 bar (1862 psi) from –46 to 59°C (–50 to 139°F) and to 103 bar (1490 psi) at 93°C (200°F). The NPS 16 with 17-4PH steel, with 2-1/2 inch splined driveshaft is limited to 1000 psi (69 bar), and with the S20910, 2-1/2 inch splined drive shaft is limited to 55 bar (795 psi) at all service temperatures. The NPS 24 with S20910 drive shaft is limited to 92 bar (1336 psi) at all service temperatures.

Valve Size, NPS A D G K L (bore diameter) R S T U W
Shaft Diameter Spline Diameter(1)
mm
4 194 206 197 162 76.2 279 31.8 31.8 235 46 5/8-UNC
6 229 356 238 194 101.6 327 50.8 50.8 273 51 3/4-UNC
8 243 356 327 270 152.4 413 63.5 63.5 337 76 7/8-UNC
10 297 356 343 287 187.5 445 69.9 63.5 337 76 7/8-UNC
12 338 356 381 324 22.86 483 76.2 63.5 337 76 7/8-UNC
16 400 470 460 392 292.1 613 101.6 63.5 553 127 1-1/4—8UN
508 88.9
20 533 508 546 480 371.3 864 127.0 88.9 553 127 1-1/4—8UN
24 679 508 629 546 438.2 991 152.4 88.9 553 127 1-1/4—8UN
Fisher V250 Full Bore Pipeline Ball Valve - Rotary Valves - Dimensions

Fisher V250 Full Bore Pipeline Ball Valve – Rotary Valves – Dimensions

See how Fisher Control Valves provide safe, efficient and intuitive flow control.

Installing Fisher V250 Full Bore Pipeline Ball Valve

Fisher V250 full bore pipeline ball valve may be installed in any position. However, the recommended orientation is in a horizontal pipeline with the shaft positioned horizontally and the ball closing in the downward direction.

Fisher Valves Typical Industries Include Power, Petrochem, Oil & Gas

Fisher Valves Typical Industries Include Power, Petrochem, Oil & Gas

âž¡ Did you know? Fisher was founded  in 1880 by William Fisher. Today Fisher valves are used throughout oil and gas, petrochemical, refining, power and paper industries – the company is now a subsidiary of the Emerson process industrial group. 