Trace Heating Cables | Nelson HLT | Medium Process Temperature Maintenance Cable

Nelson Heat Trace Type HLT Self-Regulating Heater Cable

Nelson Heat Trace Type HLT Self-Regulating Heater Cable

Trace Heating

Nelson Heat Trace HLT self-regulating trace heating cables provide process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 121ºC. The Nelson Heat Trace HLT heater cable is ATEX certified for use within Zone 1 & Zone 2 hazardous area applications.

Nelson Heat Trace HLT Trace HEATing CABLE – Features & Benefits

  • Available for both 120 Vac and 240 Vac applications in a wide range of power densities from 3 to 20 watts per foot at 10°C/50°F
  • Parallel-resistance design allows cables to be Cut-to-Length in the field with no danger of creating cold or dead zones
  • Metal braid with a fluoropolymer overjacket resists moisture, corrosion and solvents
  • HLT cables are UL Listed, CSA Certified and FM Approved
  • Freeze protection for metallic pipes that are periodically steam cleaned at temperatures up to 191°C/375°F
  • Maintaining the temperature and viscosity of piped liquids in applications that require a temperature of 121°C/250°F or lower
  • Piping systems for hydrocarbons and chemical products
  • Classified hazardous locations

Nelson Heat Trace HLT Trace Heating CABLE – SPECIFICATION

Nelson Heat Trace Cable Part Number Supply Voltage Maximum Segment Length Description Maximum Maintenance Temperature Maximum Intermittent Exposure Temperature Watts / M (Watts / ft)
HLT5-CB 120 85m (280ft) Tinned Copper Braid 120ºC / 250ºF 215ºC / 420ºF 16 (5)
HLT5-J Tinned Copper Braid & Fluoropolymer
D1-HLT5 Class 1, Division 1, Groups B, C and D
HLT25-CB 240 170m (560ft) Tinned Copper Braid
HLT25-J Tinned Copper Braid & Fluoropolymer
D1-HLT25 Class 1, Division 1, Groups B, C and D
HLT10-CB 120 60m (195ft) Tinned Copper Braid 33 (10)
HLT10-J Tinned Copper Braid & Fluoropolymer
D1-HLT10 Class 1, Division 1, Groups B, C and D
HLT210-CB 240 120m (390ft) Tinned Copper Braid
HLT210-J Tinned Copper Braid & Fluoropolymer
D1-HLT210 Class 1, Division 1, Groups B, C and D
HLT15-CB 120 40m (135ft) Tinned Copper Braid 49 (15)
HLT15-J Tinned Copper Braid & Fluoropolymer
D1-HLT15 Class 1, Division 1, Groups B, C and D
HLT215-CB 240 80m (270ft) Tinned Copper Braid
HLT215-J Tinned Copper Braid & Fluoropolymer
D1-HLT215 Class 1, Division 1, Groups B, C and D
HLT20-CB 120 30m (105ft) Tinned Copper Braid 66 (20)
HLT20-J Tinned Copper Braid & Fluoropolymer
D1-HLT20 Class 1, Division 1, Groups B, C and D
HLT220-CB 240 65m (210ft) Tinned Copper Braid
HLT220-J Tinned Copper Braid & Fluoropolymer
D1-HLT220 Class 1, Division 1, Groups B, C and D

Certifications and Compliances

  • UL Listed: E33597, E53501, E49805
  • CSA Standard: C22.2 No. 130-16
  • CSA Certified: LR42103, LR42104
  • FM Approved: JI 5D0A4.AX, JI 3B3A6.A6, JI 3B6A4.AX
  • Other Standards: IEEE 515-2011, IEEE 515.1-2012