EXHEAT HFT40 Hazardous Area Thermostats | Flameproof Air Sensing Thermostat Zone 1 Zone 2

EXHEAT HFT40 Hazardous Area Thermostats - Flameproof Air Sensing Thermostat (Zone 1 & Zone 2)


EXHEAT HFT40

Hazardous Area Thermostats

EXHEAT HFT40 hazardous area thermostats provide temperature control for hazardous area heating and air warming for Zone 1 & Zone 2 (Flammable Gas) explosive atmospheres according to ATEX Directive.

The EXHEAT HFT40 thermostat is supplied in a weatherproof or explosion proof enclosure to compliment the range of hazardous area air warmers and is designed for the temperature control of work or storage areas – suitable for ambient temperatures from -60°C to +60°C.

EXHEAT HFT40 Hazardous Area Thermostats


HFT40 Hazardous Area Thermostats Key Features

  • Temperature range: 0–40°C

  • Rated current: 20A at 250V AC

  • Flameproof Ex d certified for Zone 1 & 2

  • ATEX and IECEx approved

  • Ingress protection: IP6X

  • Aluminium flameproof enclosure

  • Internal or external adjustment options

  • Installation – wall mounted thermostats for hazardous area locations

  • Ambient temperatures from -60°C to +60°C

Specification Details
Model HFT40
Temperature Range 0°C to 40°C
Current Rating 20A (250V AC)
Enclosure Aluminium, flameproof Ex d
Ingress Protection IP6X
Mounting Wall / surface mount
Adjustment Internal or external option
Certification ATEX, IECEx compliant

EXHEAT HFT40 Hazardous Area Thermostats

ATEX CERTIFICATION

Certification: ATEX / IECEx    II 2G Ex db IIC T6 Gb
CSA (CEC / NEC) Class I, Division 2, Groups A, B, C, D; T6, Type 4X (USA / CAN)
CSA (CEC) Ex db IIC; T6 Gb; IP66 (CAN)
CSA (NEC) Class I, Zone 1, AEx db IIC; T6 Gb; IP66 (USA)
CU TR (EAC)

ATEX / IECEx    II 2G Ex db IIC T6 Gb

CSA (CEC / NEC) Class I, Division 2, Groups A, B, C, D; T6, Type 4X (USA / CAN)
CSA (CEC) Ex db IIC; T6 Gb; IP66 (CAN)
CSA (NEC) Class I, Zone 1, AEx db IIC; T6 Gb; IP66 (USA)

CU TR (EAC)

Wiring Diagram HFT

This sample Wiring Drawing is for the EXHEAT HFT model of thermostats – for all other heater wiring drawings refer to the O&M download opposite.

Please download EXHEAT HFT hazardous area thermostats O&M manual for full details on installation and maintenance procedures – this includes wiring diagrams, earth connection and pre installation inspection and checks.

Specification Details
Enclosure Cast 316 stainless steel with 2 × M20 cable entries, external and internal earths and internal neutral link, ingress protection IP66
Controls Choice of control range: 0°C to 40°C or 0°C to 60°C
Mounting 2 × 6mm dia shrouded mounting holes are provided. Wall mounted
Voltage SPDT, 20A on 250VAC in a choice of switching configuration
Ambient Temperature -60ºC to +60ºC

EXHEAT HFT40 HAZARDOUS AREA thermostats – APPLICATIONS

Applications for these hazardous area thermostats include:

  • Accumulator System Cabinet
  • Acoustic Enclosure
  • Air Heating for Instrumentation
  • Anti Condensation Heater
  • Anti-Freeze
  • Battery Cabinet Heater
  • Cabinet
  • Chemical Injection Cabinet
  • Compressor Enclosure
  • Compressor Frame Enclosure
  • Condensation Prevention
  • Control / Monitoring Panels
  • Control Housing
  • Diesel Generator Enclosure
  • Electrical Panel
  • Enclosures
  • Fire Equipment Cabinet
  • Frost Protection
  • Gas Seal Panel
  • GRP Enclosure
  • Hazardous Area Process Temperature Measurement
  • Heating Cabinet
  • Instrumentation Cabinet
  • Instrumentation for Compressor Package
  • Junction Boxes
  • Machine Enclosure
  • Motor Cases/Enclosures
  • Motor Enclosure
  • Offshore Cabinet
  • Offshore Panel Heater
  • Outdoor Telecommunications Cabinet
  • Panel for Compressors
  • Panel Heaters
  • Power Distribution Panels
  • Process Temperature Measurement
  • Pump Enclosure Safety Stat
  • Silo Base Enclosure warming
  • Skid Enclosure
  • Switchgear Panel/Cubicles
  • Temperature Measurement
  • Thermowell Assemblies
  • Thermowells
  • Transformer Enclosures
  • Transmitter Enclosures
  • Wardrobe

EXHEAT HFT40 Hazardous Area Thermostats

These HFT40 hazardous area thermostats are suitable for Zone 1 & Zone 2 (IIA, IIB, IIC) gas groups according to ATEX.

EXHEAT HFT Hazardous Area Thermostats - Dimensions

EXHEAT HFT Hazardous Area Thermostats – Dimensions

EXHEAT HFT40 Thermostat FAQs


What is the temperature range of the EXHEAT HFT40?

The EXHEAT HFT40 operates within a specific temperature range ideal for industrial applications. Discover the exact range and its use cases.


Is the HFT40 suitable for hazardous areas?

The HFT40 meets key certifications for hazardous locations. Find out where it can be safely installed.


What is the current rating of the HFT40 thermostat?

This thermostat is designed for industrial power loads. Learn more about its current and voltage ratings.


Related Products

Need Help Choosing the Right Model?

Speak to our hazardous area heating specialists for expert advice on product selection, certification support, or installation queries.

  • Over 40 years’ experience in industrial heating

  • Authorised EXHEAT distributor

  • Fast UK & international delivery

Contact Our Experts

Air Heaters | Immersion Heaters | Line Heaters | Thermostats | ATEX & IECEX Certified Electrical Heaters

Air Heaters | Immersion Heaters | Line Heaters | Thermostats | ATEX & IECEX Certified Electrical Heaters

T&D – EXPERTS IN EQUIPMENT FOR EXPLOSIVE ATMOSPHERESExplosive Atmospheres EX

Trust Thorne & Derrick to specify and supply from stock safe and reliable Heat, Light & Power Products for use in hazardous area locations and explosive atmospheres certified to international standards including ATEX and IECEx – this includes Zone 1 / Zone 2 (Flammable Gas) or Zone 21 / Zone 22 (Dusts) and Class I, Division 1 and Division 2 hazardous area requirements.

Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.

 

Lighting | Sockets | Glands | Control Stations | Isolators | Push Buttons | Hazardous Area Equipment UK & Export Sales

Lighting | Sockets | Glands | Control Stations | Isolators | Push Buttons | Hazardous Area Equipment UK & Export Sales

Download Technical Data Sheet

Data Sheets