45kV Enclosure – HV High Voltage Junction Box Zone 1 Hazardous Area

45kV Enclosure - HV High Voltage Junction Box Zone 1 Hazardous Area

HV Enclosures & Junctions Up to 45kV

Abtech 4TJB high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution up to 45kV systems up to 1000sqmm cables – ATEX certified for Zone 1 and Zone 2 connection of HV cables in hazardous area locations.

The Abtech 4TJB can accept three phase connections either straight through or bottom entry only. The 45kV enclosure has heavy duty machined hinges with lift off cover pad-lockable cover and is DTS-01 deluge tested.

Abtech 4TJB high voltage (HV) cable junction boxes are manufactured from 316L stainless steel and used primarily for jointing cables or as a connection box, the 4TJB is capable of connecting three phases straight through or bottom entry only and one conductor per phase in and out.

HIGH VOLTAGE HV JUNCTION BOX

ZONE 1 & ZONE 2 HAZARDOUS AREA

ATEX CERTIFIED

ABTECH 4TJB

Abtech 4TJB High Voltage Hazardous Area Electrical Enclosures

HV Junction Boxes Manufactured From 316 Stainless Steel For Offshore 45kV High Voltage Cable Connections & Terminations

High Voltage Junction Box 45kV - Zone 1 Zone 2 Hazardous Area ATEX

Abtech TFJB General Arrangement HV Enclosure Drawing – cable termination, enclosure and junction box suitable for jointing, connecting and terminating HV cables 45kV.

Abtech Part Ref Width (mm) Height (mm) Depth (mm) Maximum Voltage (kV) Maximum Current (A) Power Rating at T4 (W) Ambient Range Weight (kg) Hazardous Area Enclosure  
4TJB (x-x) 1300 1500 to 2000 500 45 980 346 -20ºC to +40ºC 290  Zone 1 & Zone 2
4TJB (x-x) 1300 1500 to 2000 500 45 980 288 -20ºC to +55ºC 290 Zone 1 & Zone 2

* (x-x) demotes the number of connectors per phase, 1st position = top, 2nd position = bottom. For example: 4TJB(1-1) = 1 x conductors per phase top entry and 1 x conductor per phase bottom entry.

HAZARDOUS AREA CERTIFICATION

High Voltage Enclosures & Junction Boxes (HV) - Hazardous Area

High Voltage Enclosures & Junction Boxes (HV) – Hazardous Area

  • ATEX EEx e (Zone 1 & Zone 2)
  • NEMA 4X (CSA, UL & FM) Class 1 Division 2
  • Deluge Tested To DTS-01

Zone 1 & 21, Gas and Dust / Class 1 Division 2

Type Of Explosion Protection – Ex tb

Apparatus Hazardous Area Coding – II 2 GD T4 Gb, Ex tb IIIC T135ºC Db

TEMPERATURE RATING

  • -20° to +40°C (-40° to 104°F) or -20ºC to +55ºC (-40° to 131°F)

HIGH VOLTAGE HV ENCLOSURE SPECIFICATION

  • Electrical Enclosure Type – High Voltage (HV)
  • Ingress Protection – IP66 to EN60529, Type 4X, DTS-01
  • Impact Resistance – >7Nm (tested above 10Nm)
  • Material – 2mm 316L Stainless Steel (EN 1.4404) enclosure with orbital finish, silicone gasket and captive 316 stainless steel fasteners, 3mm 316L (EN 1.4404) Stainless Steel gland plates
  • Ambient Temperature Rating – 20°C to +40°C, – 20°C to +55°C
  • Suitable for 45kV
  • Maximum Terminations – 1 conductor per phase in & 1 conductor per phase out
  • Number of Gland Plates – Dependant upon configuration
  • Crimp Lugs – 6mm² to 1000mm²
  • Earthing – Via Studs On Electrical Enclosure, Door & Cable Gland Plates
  • Mounting – Via heavy duty 3mm thick external angle frames

ENCLOSURE OPTIONS

  • Abtech 4TJB ACH HV Junction Box Enclosure – Anti-condensation heater
  • Abtech 4TJB EP HV Junction Box Enclosure – Electro-polished
  • Abtech 4TJB PS HV Junction Box Enclosure – Epoxy powder coated, smooth finish (RAL colour may be specified)
  • Abtech 4TJB PT HV Junction Box Enclosure – Epoxy powder coated, Hammer Grey
  • Abtech 4TJB MB HV Junction Box Enclosure – Mounting boss for eye bolts

Add the required suffix to the product reference. Example:  Abtech 4TJB(1-1)PT = 4TJB with 1 x conductors per phase top entry and 1 x conductor per phase bottom entry with Hammer Grey paint finish

MV HV ELECTRICAL ENCLOSURES & JUNCTION BOXES
3.3KV 6.6KV 11KV 33KV HIGH VOLTAGES

T&D produce customised HV Junction Boxes & Electrical Enclosures suitable for safe installation and distribution of MV-HV electrical power in hazardous area locations – enclosures and junction boxes can be specified and supplied for 3.3kV, 6.6kV, 11kV and 33kV high voltage power networks where Ex-certified HV electrical equipment is required in accordance with ATEX and IECEx hazardous area certification.

HV High Voltage Electrical Enclosures Junction Boxes

HV High Voltage Specialists – Zone 1 & Zone 2 Hazardous Area Certified By ATEX

➡ View complete range: HV Junction Boxes & Electrical Enclosures

HV Enclosures Junction Boxes

MV-HV Junction Boxes & Electrical Enclosures For 3.3kV, 11kV and 33kV Medium-High Voltage Networks – Industrial & Hazardous Area

Data Sheets