Constant Wattage Heat Tracing | Eltherm ELKM-AG-N ATEX Heat Tracing Cable up to 260°C
Constant Wattage heat tracing cables
ATEX Heat Tracing Cable | Eltherm ELKM-AG-N
Eltherm ELKM-AG-N constant wattage heat tracing cables provide process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 260° Celsius.
These heat tracing cables manufactured by Eltherm offer flexibility in use as they can easily be cut to the required length off the roll, with the assurance of constant power output. There is no need for connecting cable and input can be unilateral. The constant wattage heat tracing cable is quick and easy to assemble, saving time and reducing operating costs.
Since the heat tracing cable output of up to 30 W/m is possible for lengths laid to piping, Eltherm ELKM-AG-N heat tracing cables are particularly suited for piping with high output requirements such as in industrial process technology. The following are applications are below:
- Pipelines
- Valves, pumps
- Tank container
- Silos, vessels, tanks
- Automotive
- Industrial Applications
- Varnishes
- IBCs
HEAT TRACING CABLES
ELTHERM ELKM-AG-N SPECIFICATION
Eltherm ELKM-AG-N Heater Cable wattages per metre – 30 watts
- Nominal Supply Voltage : 550V
- Maximum Output : 30 w/m
- Maximum Operating Temperature : 260ºC
- Minimum Installation Temperature : -60° Celsius
- Minimum Heater Cable Bend Radius : 2.5mm x outer diameter
- Insulation : Fluoropolymer
- Protective Braid: Nickel-plated Copper
- Outer Jacket: Fluoropolymer
- Heat Conductor : Stranded, spirally wound for nominal resistance > 8000 Ω/km
- Impact Resistance: 4 Joule
* The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application.
- Heating conductor: Heating conductor stranded or spirally wound
- Insulation: Fluoropolymer
- Protective braid: Nickel-plated copper
- Outer jacket: Fluoropolymer
Hazardous Area Classifications
System Classification:
- II 2G Ex 60079-30-1 IIC Gb
- II 2D Ex 60079-30-1 IIIC Db
Hazardous Area Certification:
- EPS 12 ATEX 1466 U
- IECEx EPS 12.0023 U
- CML 21 UKEX 3804 U
Eltherm ELKM-AG-N Heating cable Benefits
- High chemical and mechanical resistance trace heating cable
- High operating temperature
- Can be used in liquids
- Easy to install, even on complex shapes
- Highly flexible
- Resistant to steam purging
resistance Heating Cables – Eltherm ELKM-AG-N
SELECTION TABLE
Contact T&D for technical guidance, heat loss calculations for pipework systems and optimum specification of the correct trace heater cable for your hazardous area heating application.
Resistance heating cables application : frost protection and process heating.
Nominal Resistance Ω/km | Cable Outer Diameter Approx (mm) | Weight Approx (g/m) | Temperature Coefficient (x 10-3/K) |
1.95 (Cu 10mm²) | 8.1 | 166 | 4.30 |
2.90 (Cu 6mm²) | 6.8 | 119 | 4.30 |
4.40 (Cu 4mm²) | 6.1 | 96 | 4.30 |
7.20 (Cu 2.5mm²) | 5.1 | 64 | 4.30 |
10.00 | 4.8 | 59 | 4.30 |
11.70 (Cu 1.5mm²) | 4.7 | 57 | 4.30 |
15.00 | 4.5 | 50 | 4.30 |
25.00 | 4.4 | 48 | 3.00 |
31.50 | 4.7 | 56 | 1.60 |
50.00 | 4.4 | 49 | 1.60 |
65.00 | 4.2 | 46 | 1.60 |
80.00 | 4.5 | 42 | 0.90 |
100.00 | 4.4 | 50 | 0.90 |
157.00 | 4.4 | 46 | 0.45 |
180.00 | 4.1 | 42 | 0.90 |
200.00 | 4.2 | 38 | 0.45 |
260.00 | 4.1 | 42 | 0.45 |
280.00 | 4.0 | 39 | 0.38 |
328.00 | 4.1 | 40.1 | 0.18 |
360.00 | 3.9 | 40 | 0.45 |
430.00 | 4.1 | 43 | 0.18 |
480.00 | 4.1 | 44 | 0.18 |
600.00 | 4.0 | 40 | 0.18 |
800.00 | 3.9 | 41 | 0.18 |
1000.00 | 4.0 | 43 | 0.04 |
1470.00 | 3.8 | 40 | 0.04 |
1750.00 | 3.8 | 37 | 0.04 |
1900.00 | 3.5 | 41 | 0.40 |
2900.00 | 3.9 | 41 | 0.40 |
4000.00 | 3.8 | 37 | 0.40 |
4700.00 | 3.8 | 35 | 0.15 |
6000.00 | 3.8 | 34 | 0.20 |
7000.00 | 3.8 | 33 | 0.15 |
8000.00 | 3.8 | 36 | 0.15 |
- Weight tolerances are possible for manufacturing reasons
- Resistance tolerance: +/- 5 %..
- Other nominal resistances upon request
Eltherm resistance heating cables are manufactured from a high-resistance heating conductor, PTFE insulated with protective braid and fluoropolymer outer jacket. Powered at specific voltage the resistance heat generated by the conductors provides electrical trace heating to pipes and vessels.
Bespoke Heated Hose Designs | 40+ Years Experience from Process Heating Specialists | CONTACT US