Ultrasonic Flowmeters & Flow Measurement – Katronic

Ultrasonic Flowmeters & Flow Measurement - Katronic

Ultrasonic Flow Measurement & Flowmeters

Ultrasonic Flow Meters

Katronic clamp-on ultrasonic flow meters and non-invasive process measurement instrumentation include both portable (hand-held) and fixed flowmeters.

ATEX certified flowmeters utilising ultrasonic clamp-on technology provide explosion-proof flow measurement in Zone 1 and Zone 2 hazardous area locations.

installing Katronic Portable ultrasonic Flowmeter

installing Katronic Fixed ultrasonic Flowmeter

Katronic KATflow Fixed & Portable Flowmeters – Overview

Flowmeter KATflow 100 KATflow 150 KATflow 170 KATflow 200 KATflow 210 KATflow 230
Flowmeter Type Fixed Installation Portable
Pipe Diameter 10 to 3,000mm 10 to 6,500mm 10 to 3,000mm 10 to 6,500mm 50 to 2,500mm 10 to 6,500mm
Temperature Range -30ºC to +80ºC (-22ºF to +176ºF) -30ºC to +250ºC (-22ºF to +482ºF) -50ºC to +115ºC (-58ºF to +239ºF) -30ºC to +250ºC (-22ºF to +482ºF) -30ºC to +130ºC (-22ºF to +266ºF) -30ºC to +250ºC (-22ºF to +482ºF)
Measurement Channels 1 1 or 2 (See note 1) 1 1 or 2
Flow Velocity Range 0.01 to 25 m/s
Accuracy of Volume Flow ±1  to 3% of measured value
±0.5% process calibrated
Accuracy Range 0.25 to 25 m/s
Weight 750g 2.3kg 4.0kg 650g 6.0kg 2.0kg
Battery Life N/A Up to 24 hours Up to 100 days with 3 cells Up to 24 hours
Power Supply 100 to 240 VAC or 9 to 36 VDC 100 to 240 VAC (Mains socket) (See note 2)
Display LCD graphic display, 128 x 64 dots, backlit
Process Inputs PT100 temperature (See note 3) 0/4 to 20mA No 0/4 to 20mA PT100 temperature (See note 3), 0/4 to 20mA
Process Outputs 0/4 to 20mA, pulse (OC) digital relay, frequency, voltage, HART compatible No 0/4 to 20mA, pulse (OC), digital relay
Communication RS 232, USB, RS 485, Modbus RTU RS 232, USB, RS 485, Modbus RTU, Profibus PA RS 232, USB USB RS 232, USB
Internal Data Logger Yes
Wall Thickness Gauge N/A Yes
Energy Metering Yes (See note 4) N/A Yes
Ex Approved Version N/A Yes N/A
1) For simultaneous measurement on two separate pipes or for measurement on one single pipe in a two-path sensor mounting configuration.
2) For charging of internal batteries and supply of flowmeter with power when connected to mains electricity socket (100 to 240 VAC input).
3) + 4) For contactless measurement of thermal energy consumption. Displayable units: W, kW, MW, J, kJ, MJ, BTU (on request).

 