Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed)

Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed)

Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed)

Non-Hazardous & Hazardous Area Flowmeters

Ultrasonic Flow Meters

Katronic’s KATflow 150 is a fixed flowmeter which utilises ultrasonic technology to measure the flow rate of liquids within pipes without entering the pipe. The KATflow 150 has a practical modular design allowing for a broad range of configuration options and different transducer types to ensure the flowmeter is suitable for applications ranging from simple water flow measurement to energy flow monitoring and automated process controls.

KATflow 150 flowmeters are suitable for pipe diameters ranging from 10mm up to 6,500mm and have a lockable IP66 polycarbonate enclosure and has an LCD display and five key keypad.

Stainless steel sensors, cables and connectors are supplied as standard for temperature ranges from -30ºC to +800ºC and the KATflow 150 can be used to measure two flows simultaneously.

Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed)

Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed)

Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed) – Features

  • Pipe diameter range 10mm to 6,500mm
  • Temperature range for sensors – -30ºC to +250ºC (-22ºF to +482ºF)
  • Lockable and sturdy IP66 polycarbonate flowmeter enclosure
  • Selectable three-line LCD display and full keypad
  • Up to ten input or output slots available
  • Measurement of two flows simultaneously
  • Dual flow monitoring with sum, average, difference and maximum calculations
  • Process output options including current, open-collector, relay
  • Communication outputs including RS 485, Modbus RTU, Profibus PA and HART compatible output
  • Current inputs for temperature, pressure and density compensation
  • Large data logger and software for sampling and data transfer
  • Optional – Heat quantity (thermal energy) measurement functionality
  • Optional – Additional secondary enclosure for ATEX applications
  • Optional – Optional sound velocity output function
  • Optional – PT100 sensors or analogue temperatures inputs for heat quantity measurement and temperature compensation
Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed) - In Operation

Katronic KATflow 150 Ultrasonic Clamp-On Flowmeter (Fixed) – In Operation

The KATflow 150 is an ideal flowmeter solution for applications including heating, ventilation and air conditioning (HVAC) measurements, large pipe measurement with two sensor pairs in ‘X’ configuration, production recognition and interface detection systems, ATEX measurements with Ex-certified transducers, automated process control and more.

KATRONIC KATFLOW 150 ULTRASONIC CLAMP-ON FLOWMETER (FIXED) – Technical Specification

Transmitter Performance
Flowmeter Measuring PrincipleUltrasonic transit time difference
Flow Velocity Range0.01 to 25m/s
Resolution0.25mm/s
Repeatability0.15% of measured value, ±0.015m/s
AccuracyVolume Flow: ±1 to 3% of measured value depending on application
±0.5% of measured value with process calibration
Flow Velocity (Mean): ±0.5% of measured value
Turn Down Ratio1/100 (Equivalent to 0.25 to 25m/s)
Measurement Rate1 Hz (Standard)
Response Time1s (Standard), 90ms (Optional)
Damping of Display Value0 to 99s (Selectable by user)
Gaseous and Solid Content of Liquid Media<10% of volume
General
Enclosure TypeWall mounted
Degree of ProtectionIP66 according to EN 60529
Operating Temperature-10 to +60ºC (+14 to +140ºF)
Housing MaterialPolycarbonate (UL94 V-0)
Measurement Channels 1 or 2
Calculation FunctionsAverage, difference, sum, maximum (dual-channel use only)
Power Supply100 to 240V AC, 50/60Hz
9 to 36V DC
Special solutions (e.g solar panel, battery) on request
DisplayLCD graphic display, 128 x 64 dots, backlit
Dimensions237mm (H) x 258mm (W) x 146mm (D)
WeightApprox 2.3kg
Power Consumption<10W
Operating LanguagesEnglish, French, German, Dutch, Spanish, Italian, Russian, Czech, Turkish, Romanian (Others on request)
Communication
TypeRS 232, USB cable (optional), RS 485 (optional), Modbus RTU (optional), HART compatible (optional), Profibus PA (optional)
Transmitted DataMeasured and totalised value, parameter set and configuration, logged data
Internal Data Logger
Storage CapacityApprox 30,000 measurements (each comprising up to 10 selectable measurement units), logger size 5MB
Approx 1000,000 measurements (each comprising up to 10 selectable measurement units), logger size 16MB
Logged DataAll measured and totalised values, parameter sets.
KATdata+ Software
FunctionalityDownload of measured values/parameter sets, graphical presentation, list format, export to third party software, online transfer of measured data
Operating SystemsWindows 8, 7, Vista, XP, NT, 2000
Linux
Quantity and Units of Measurement
Volumetric Flow Ratem³/h, m³/min, m³/s, l/h, l/min, l/s
USgal/h (US gallons per hour), USgal/min, USgal/s
bbl/d (Barrels per day), bbl/h, bbl/min
Flow Velocitym/s, ft/s, inch/s
Mass Flow Rateg/s, t/h, kg/h, kg/min
Volumem³, l, gal (US gallons), bbl
Massg, kg, t
Heat FlowW, kW, MW (with heat quantity measurement option)
Heat QuantityJ, kJ, kW/h (with heat quantity measurement option)
TemperatureºC (with heat quantity measurement option)
Process Inputs (Galvanically Isolated)
TemperaturePT100 (clamp-on sensors), three-or four-wire circuit, measurement range: -30 to +250ºC (-22ºF to +482ºF), resolution: 0.1K, accuracy: ±0.2K
Current0/4 to 20mA active or 0/4 to 20mA passive, U = 30V, Ri = 50Ω, accuracy: 0.1% of measured value
Process Outputs (Galvanically Isolated)
Current0/4 to 20mA active/passive (R load <500 Ω), 16 bit resolution, U = 30V, accuracy: 0.1%
Digital Open-CollectorValue: 0.01 to 1000/unit, width: 1 to 990ms, U = 24V, l max = 4mA
Digital Relay2 x Form A SPST (NO and NC), U = 48V, l max = 250mA
Voltage0 to 10V, R load = 1000 Ω
Frequency2Hz to 10kHz, 24/4mA
HART Compatible0/4 to 20mA, 24V DC, R GND = 220Ω

Visit Katronic KATflow 170 for hazardous area flowmeters with ATEX Certification for metering the flow in Zone 1 and Zone 2 explosive atmospheres.

Katronic KATflow 150 Ultrasonic clamp-on Flowmeter

See the features of Katronic KATflow 150 flowmeter in this video including IP 66 enclosure, durable sensor connections and stainless steel sensor heads.

Katronic KATFlow 150 Ultrasonic Flow Meter Applications
Manufacturing and ProcessCooling systems on injection moulding machines

Measurement of paint flows

Fire pump control

Water and WastewaterDual-pipe metering for cost saving

Replacement of large bore electromagnetic flowmeters

Effluent metering

Building ServicesInstallation on hot water lines

Dual-channel energy flow measurement

Installation on chilled water systems

SemiconductorDemineralised water measurements

Control of hydrofluoric acid flows

Measurement in clean room environment

PharmaceuticalWater for injection measurement

Measurement of sterile fluids

Clean in process (CIP) system monitoring

General IndustryAutomated process control

Measurement of furnace cooling flows

Fuel and oil consumption measurements

Flow Meters : Ultrasonic & Clamp-on Portable Meters

Flow Meters: Ultrasonic & Clamp-on Portable Meters

T&D Metering Specialists - Gas, Water & Heat Meter Suppliers

T&D Metering Specialists – Gas, Water & Heat Meter Suppliers

➡ Did you know? ASCO solenoid valves provide flow control of oil, gas, air, steam and water. Contact T&D Sales.